TeSys D contactor 3P AC3 150A 24V DC coil

In stock
SKU
LC1D150BD
Add to Compare
IQD  554,350
Add to Wish List
Category :
Payment methods available
  • [Ue] rated operational voltage : Power circuit: <= 1000 V AC 25...400 Hz
  • Power circuit: <= 300 V DC

About The Product


TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 150A/1000V AC-3 (75kW@400V) , power connection by screw connectors 2 inputs, control connection by screw clamp terminals , it procures high reliability and durability.

Technical Data


  • [Ue] rated operational voltage : Power circuit: <= 1000 V AC 25...400 Hz
  • Power circuit: <= 300 V DC
  • [Ie] rated operational current : 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
  • 150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
  • 150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
  • [Uc] control circuit voltage : 24 V DC
  • Motor power kW : 40 kW at 220...230 V AC 50/60 Hz (AC-3)
  • 75 kW at 380...400 V AC 50/60 Hz (AC-3)
  • 80 kW at 415...440 V AC 50/60 Hz (AC-3)
  • 90 kW at 500 V AC 50/60 Hz (AC-3)
  • 100 kW at 660...690 V AC 50/60 Hz (AC-3)
  • 75 kW at 1000 V AC 50/60 Hz (AC-3)
  • 22 kW at 400 V AC 50/60 Hz (AC-4)
  • 40 kW at 220...230 V AC 50/60 Hz (AC-3e)
  • 75 kW at 380...400 V AC 50/60 Hz (AC-3e)
  • 80 kW at 415...440 V AC 50/60 Hz (AC-3e)
  • 90 kW at 500 V AC 50/60 Hz (AC-3e)
  • 100 kW at 660...690 V AC 50/60 Hz (AC-3e)
  • 75 kW at 1000 V AC 50/60 Hz (AC-3e)
  • Motor power hp : 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors
  • 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors
  • 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors
  • 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors
  • Pole contact composition : 3 NO
  • [Ith] conventional free air thermal current : 200 A (at 60 °C) for power circuit
  • Irms rated making capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signaling circuit conforming to IEC 60947-5-1
  • 1660 A at 440 V for power circuit conforming to IEC 60947
  • Rated breaking capacity : 1400 A at 440 V for power circuit conforming to IEC 60947
  • Power dissipation per pole : 24 W AC-1
  • 13.5 W AC-3
  • 13.5 W AC-3e
  • [Uimp] rated impulse withstand voltage : 8 kV conforming to IEC 60947
  • Mechanical durability : 8 Mcycles
  • Electrical durability : 0.85 Mcycles 150 A AC-3 at Ue <= 440 V
  • 1 Mcycles 200 A AC-1 at Ue <= 440 V
  • 0.85 Mcycles 150 A AC-3e at Ue <= 440 V
  • Control circuit voltage limits : 0.75...1.2 Uc (-40…55 °C):operational DC
  • 0.15...0.4 Uc (-40…70 °C):drop-out DC
  • 1...1.2 Uc (55…70 °C):operational DC
  • Inrush power in W : 270…365 W (at 20 °C)
  • Hold-in power consumption in W :2.4…5.1 W at 20 °C
  • Operating time : 20...35 ms closing
  • 40...75 ms opening
  • Time constant : 25 ms
  • Maximum operating rate : 1200 cyc/h 60 °C
  • Permissible ambient air temperature around the device : -40…60 °C
  • 60…70 °C with derating
  • Fire resistance : 850 °C conforming to IEC 60695-2-1
  • Height : 158 mm
  • Width : 120 mm
  • Depth : 136 mm
  • Net weight : 2.5 kg
Write Your Own Review
You're reviewing:TeSys D contactor 3P AC3 150A 24V DC coil
Your Rating
Products from the same Schneider Electric
  1. Overload relay 1 A - 1.6A |LRD06
    Rating:
    0%
    ( 0 Reviews )
    Overload relay 1 A - 1.6A |LRD06
    IQD  28,350
  2. Acti9 iID - RCCB - 4P - 100A - 30mA | A9R11491
    Rating:
    0%
    ( 0 Reviews )
    Acti9 iID - RCCB - 4P - 100A - 30mA | A9R11491
    IQD  245,500
  3. Overload relay 1.6 A - 2.5A |LRD07
    Rating:
    0%
    ( 0 Reviews )
    Overload relay 1.6 A - 2.5A |LRD07
    IQD  28,350
  4. Overload relay .2.5 A - 4A |LRD08
    Rating:
    0%
    ( 0 Reviews )
    Overload relay .2.5 A - 4A |LRD08
    IQD  28,350