Description

The Yaoan YR-GCG1000 Ultra Large Range Dust Concentration Measuring Instrument is designed for industrial environments with extremely high dust concentrations and severe pollution conditions. Its ultra-wide measuring capability makes it suitable for heavy-duty dust monitoring where conventional lower-range instruments may not provide sufficient capacity.

The YR-GCG1000 offers a measuring range of 0 to 1000 mg/m³ and is designed for high-pollution and harsh dust environments. A Yaoan product demonstration for this exact model also describes it as an ultra-large-range dust concentration instrument intended for concentrations up to 1000 mg/m³, with detection resolution reaching 0.01 mg.

A clear digital display provides direct real-time readings of dust concentration. The interface uses large characters and distinct normal and alarm indications, helping operators quickly identify current dust levels and warning status.

For improved durability, the instrument features a strong anti-fouling design. The supplied product information describes a special dust-removal structure and filter membrane system intended to reduce contamination inside the sensing section while maintaining stable measurements in heavily polluted environments.

The detector can store up to 30 alarm records in a loop for later retrieval and analysis. Its filter structure is also designed for straightforward maintenance and cleaning, supporting long-term use in challenging industrial environments.

The YR-GCG1000 is particularly suitable for heavy industrial sites, high-dust production areas and other applications where very high particulate concentrations need to be monitored continuously. Yaoan currently lists dust monitoring equipment as part of its industrial monitoring product range.

Features

  • Ultra Large Measuring Range: Measures industrial dust concentrations from 0 to 1000 mg/m³.
  • Designed for Heavy Pollution: Suitable for high-concentration and extremely harsh dust environments.
  • High Resolution: Detection resolution can reach 0.01 mg according to Yaoan's product demonstration.
  • Direct Digital Readout: Large digital display provides clear real-time dust concentration readings.
  • Clear Alarm Indication: Distinct normal and alarm display states simplify status recognition.
  • Strong Anti Fouling Design: Dust-removal structure and filter membrane help reduce contamination.
  • Easy Maintenance: Filter components are designed for cleaning and servicing during long-term operation.
  • Alarm Record Storage: Stores up to 30 alarm records for review and analysis.
  • Fast Response: Response time under 20 seconds according to the supplied product sheet.
  • Optional Interface Expansion: Interface configuration can be expanded depending on installation requirements.
  • Industrial Design: Intended for continuous monitoring in demanding dust-heavy environments.

Specifications

Specification Details
Brand Yaoan
Model YR-GCG1000
Product Type Ultra Large Range Dust Concentration Measuring Instrument
Detection Object Industrial Dust
Measuring Range 0 to 1000 mg/m³
Minimum Resolution 0.01 mg
Display Digital Direct Reading Display
Operating Temperature -20°C to 60°C
Humidity Range <95% RH
Response Time <20 Seconds
Measurement Error ≤ ±20 mg/m³ according to supplied product data
Data Storage Up to 30 Alarm Records
Maintenance Cleanable Filter and Anti Fouling Structure
Interface Expandable Optional Interface
Dimensions 212 × 186 × 112 mm
Product form

Yaoan Ultra Large Range Dust Concentration Measuring Instrument | YR GCG1000

    SKU: YR-GCG1000

      Description

      The Yaoan YR-GCG1000 Ultra Large Range Dust Concentration Measuring Instrument is designed for industrial environments with extremely high dust concentrations and severe pollution conditions. Its ultra-wide measuring capability makes it suitable for heavy-duty dust monitoring where conventional lower-range instruments may not provide sufficient capacity.

      The YR-GCG1000 offers a measuring range of 0 to 1000 mg/m³ and is designed for high-pollution and harsh dust environments. A Yaoan product demonstration for this exact model also describes it as an ultra-large-range dust concentration instrument intended for concentrations up to 1000 mg/m³, with detection resolution reaching 0.01 mg.

      A clear digital display provides direct real-time readings of dust concentration. The interface uses large characters and distinct normal and alarm indications, helping operators quickly identify current dust levels and warning status.

      For improved durability, the instrument features a strong anti-fouling design. The supplied product information describes a special dust-removal structure and filter membrane system intended to reduce contamination inside the sensing section while maintaining stable measurements in heavily polluted environments.

      The detector can store up to 30 alarm records in a loop for later retrieval and analysis. Its filter structure is also designed for straightforward maintenance and cleaning, supporting long-term use in challenging industrial environments.

      The YR-GCG1000 is particularly suitable for heavy industrial sites, high-dust production areas and other applications where very high particulate concentrations need to be monitored continuously. Yaoan currently lists dust monitoring equipment as part of its industrial monitoring product range.

      Features

      • Ultra Large Measuring Range: Measures industrial dust concentrations from 0 to 1000 mg/m³.
      • Designed for Heavy Pollution: Suitable for high-concentration and extremely harsh dust environments.
      • High Resolution: Detection resolution can reach 0.01 mg according to Yaoan's product demonstration.
      • Direct Digital Readout: Large digital display provides clear real-time dust concentration readings.
      • Clear Alarm Indication: Distinct normal and alarm display states simplify status recognition.
      • Strong Anti Fouling Design: Dust-removal structure and filter membrane help reduce contamination.
      • Easy Maintenance: Filter components are designed for cleaning and servicing during long-term operation.
      • Alarm Record Storage: Stores up to 30 alarm records for review and analysis.
      • Fast Response: Response time under 20 seconds according to the supplied product sheet.
      • Optional Interface Expansion: Interface configuration can be expanded depending on installation requirements.
      • Industrial Design: Intended for continuous monitoring in demanding dust-heavy environments.

      Specifications

      Specification Details
      Brand Yaoan
      Model YR-GCG1000
      Product Type Ultra Large Range Dust Concentration Measuring Instrument
      Detection Object Industrial Dust
      Measuring Range 0 to 1000 mg/m³
      Minimum Resolution 0.01 mg
      Display Digital Direct Reading Display
      Operating Temperature -20°C to 60°C
      Humidity Range <95% RH
      Response Time <20 Seconds
      Measurement Error ≤ ±20 mg/m³ according to supplied product data
      Data Storage Up to 30 Alarm Records
      Maintenance Cleanable Filter and Anti Fouling Structure
      Interface Expandable Optional Interface
      Dimensions 212 × 186 × 112 mm