Description

About the product


 Its rated voltage is 200VDC to 250 VDC or 200VAC to 250 VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage Un rises above 70% of its rated voltage Un. 

Technical data


range MasterPact
range of product MasterPact NT
MasterPact NW
MasterPact NW DC
device short name MX
product or component type Voltage release
device application Control
voltage release type
Opening coil
Instantaneous voltage release
control type Standard
[Uc] control circuit voltage
200...250 V AC 50/60 Hz
200...250 V DC
Circuit breaker mounting mode Fixed
range compatibility
Masterpact (MasterPact NT)
Masterpact (MasterPact NW)
Masterpact (MasterPact NW DC)
Operating threshold 0.7...1.1 x Un opening
response time
50 ms +/- 10 % for MasterPact NT
50 ms +/- 10 % for MasterPact NW
supply holding power 4.5 VA
Product form

Standard opening voltage release MX, MasterPact NT/NW fixed | 200/250VDC, 200/250VAC

Shop Standard opening voltage release MX, MasterPact NT/NW fixed | 200/250VDC, 200/250VAC For Best Price Online At Toolmart Read more

SKU: 47363

130,000 IQD

    Shop Standard opening voltage release MX, MasterPact NT/NW fixed | 200/250VDC, 200/250VAC For Best Price Online At Toolmart

    Description

    About the product


     Its rated voltage is 200VDC to 250 VDC or 200VAC to 250 VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage Un rises above 70% of its rated voltage Un. 

    Technical data


    range MasterPact
    range of product MasterPact NT
    MasterPact NW
    MasterPact NW DC
    device short name MX
    product or component type Voltage release
    device application Control
    voltage release type
    Opening coil
    Instantaneous voltage release
    control type Standard
    [Uc] control circuit voltage
    200...250 V AC 50/60 Hz
    200...250 V DC
    Circuit breaker mounting mode Fixed
    range compatibility
    Masterpact (MasterPact NT)
    Masterpact (MasterPact NW)
    Masterpact (MasterPact NW DC)
    Operating threshold 0.7...1.1 x Un opening
    response time
    50 ms +/- 10 % for MasterPact NT
    50 ms +/- 10 % for MasterPact NW
    supply holding power 4.5 VA
    • Multiple shipping options local and international

    • Original international brands

    • 100% secure payment methods

    • 24/7 support

    Viewed Products

    All Rights Reserved © TOOLMART 2025