Description

About the product


This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. It has control of on load electric circuit, already protected against overloads and short circuit.

Technical data 


range Domae
product or component type
Residual current circuit breaker (RCCB)
device short name RCCB
poles description 4P
earth-leakage protection class Type AC
neutral position Left
device location in system Outgoer
[In] rated current 63 A
network type AC
network frequency 50/60 Hz
[Ue] rated operational voltage
400 V AC 50/60 Hz conforming to IEC 61008
residual current tripping technology Electromechanical
earth-leakage sensitivity 30 mA
earth-leakage protection time delay Instantaneous
rated breaking and making capacity Im = 630 A
rated conditional short-circuit current 6 kA 63 A
[Ui] rated insulation voltage 440 V
[Uimp] rated impulse withstand voltage 4 kV
control type Toggle
mounting mode Fixed
mounting support
35 mm symmetrical DIN rail
9 mm pitches 8
height 81 mm
width 72 mm
depth 76 mm
connections - terminals
Tunnel type terminals (downstream) 25 mm² flexible
Tunnel type terminals (downstream) 35 mm² rigid
Tunnel type terminals (upstream) 25 mm² flexible
Tunnel type terminals (upstream) 35 mm² rigid
Product form

Residual current circuit breaker | 4 poles - 63 A - class AC 30mA

SKU: 16794

67,500 IQD

    Description

    About the product


    This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. It has control of on load electric circuit, already protected against overloads and short circuit.

    Technical data 


    range Domae
    product or component type
    Residual current circuit breaker (RCCB)
    device short name RCCB
    poles description 4P
    earth-leakage protection class Type AC
    neutral position Left
    device location in system Outgoer
    [In] rated current 63 A
    network type AC
    network frequency 50/60 Hz
    [Ue] rated operational voltage
    400 V AC 50/60 Hz conforming to IEC 61008
    residual current tripping technology Electromechanical
    earth-leakage sensitivity 30 mA
    earth-leakage protection time delay Instantaneous
    rated breaking and making capacity Im = 630 A
    rated conditional short-circuit current 6 kA 63 A
    [Ui] rated insulation voltage 440 V
    [Uimp] rated impulse withstand voltage 4 kV
    control type Toggle
    mounting mode Fixed
    mounting support
    35 mm symmetrical DIN rail
    9 mm pitches 8
    height 81 mm
    width 72 mm
    depth 76 mm
    connections - terminals
    Tunnel type terminals (downstream) 25 mm² flexible
    Tunnel type terminals (downstream) 35 mm² rigid
    Tunnel type terminals (upstream) 25 mm² flexible
    Tunnel type terminals (upstream) 35 mm² rigid