Shop Legrand MCB DX3 6000A 3 Pole 2A Curve D Circuit Breaker | 408082 In Iraq Best Prices

Thermal magnetic circuit-breaker with 3-pole, 2A D-curve, 6kA breaking capacity, and IP20 finger-safe protection for reliable electrical system protection.
The Legrand MCB DX3 6000A is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. With a 3-pole configuration, 2A rated current, and D-curve characteristic, this device delivers reliable protection for residential and small commercial electrical systems. It features a 6kA breaking capacity according to IEC60898-1 standard and IP20 finger-safe protection to prevent accidental contact with live parts. The device can be supplied by copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar, offering flexible installation options for various electrical configurations. This circuit-breaker is equipped with two DIN rail clamps (top and bottom) allowing independent removal while the prong busbar remains in place. The MCB DX3 includes a convenient label holder for clear circuit identification and status indication with ON/OFF markings on the handle in green and red backgrounds respectively. It can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and accessories for enhanced functionality and customization. The device complies with substance-restriction requirements and has been designed with environmental consciousness in mind. With a rated voltage of 400V AC, rated insulation voltage of 500V, and rated impulse withstand voltage of 4kV, this MCB provides comprehensive protection across multiple electrical parameters. The tripping threshold in case of short-circuit ranges between 20A and 28A (D curve between 10 In and 14 In), ensuring optimal protection without nuisance trips. Suitable for connectable conductor cross-sections from 1.5-35mm² (solid-core) and 1.5-25mm² (multi-wired), this device accommodates various cable types and installation requirements.

Key Features

  • 6kA breaking capacity according to IEC 60898-1 standard for household installations
  • D-curve tripping characteristic with short-circuit threshold between 20A and 28A (10-14 In)
  • IP20 finger-safe protection against solid bodies larger than 12.5mm per IEC/EN 60529
  • Compatible with copper cable, prong busbar, fork busbar, and Legrand HX3 plug busbar
  • Dual DIN rail clamps allowing independent removal while busbar remains in place
  • Label holder for clear circuit identification with ON/OFF status indication
  • Compatible with Legrand DX3 auxiliaries, RCD add-on modules, and accessories
  • Supports aluminum cable with terminal accessory connection
  • Halogen-free design with environmentally conscious manufacturing process
  • Wide operating temperature range from -25°C to +70°C

Technical Specifications

Specification Value
Product NameMCB DX3 6000A 3 Pole 2A Curve D
Reference Number408082
EAN Code3245064080828
Number of Poles3 poles (3P)
Rated Current2 A
Release CharacteristicD-curve
Rated Voltage400 V AC
Rated Insulation Voltage500 V
Rated Impulse Withstand Voltage4 kV
Voltage TypeAC (Alternating Current)
Breaking Capacity IEC 608986 kA at 400V
Breaking Capacity IEC 60947-2 (230V)25 kA
Breaking Capacity IEC 60947-2 (400V)10 kA
Frequency Range50-60 Hz
Degree of ProtectionIP20 (Finger-safe)
Degree of Impact StrengthIK02
Built-in Depth44 mm
Width53.1 mm
Height94.8 mm
Overall Depth77.8 mm
Modular Width3 modular spacings
Connectable Conductor Cross-Section (Solid-Core)1.5-35 mm²
Connectable Conductor Cross-Section (Multi-Wired)1.5-25 mm²
Connection TypeScrewed terminal
Mounting MethodDIN rail
Operating Temperature Range-25°C to +70°C
Storage Temperature Range-40°C to +70°C
Pollution Degree2
ColourGrey
RAL Number7035
Halogen FreeYes
Flush-Mounted InstallationYes
Concurrently Switching NeutralNo
Additional Equipment PossibleYes
Explosion-ProofNo
Label Space/Information SurfaceYes
Supply DirectionBy the top or bottom
Carbon Footprint (Manufacturing Phase)3.192 kg CO₂ eq.

Order Legrand MCB DX3 6000A 3 Pole 2A Curve D Circuit Breaker | 408082 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand MCB DX3 6000A 3 Pole 2A Curve D Circuit Breaker | 408082

    SKU: 408082

      Description

      Shop Legrand MCB DX3 6000A 3 Pole 2A Curve D Circuit Breaker | 408082 In Iraq Best Prices

      Thermal magnetic circuit-breaker with 3-pole, 2A D-curve, 6kA breaking capacity, and IP20 finger-safe protection for reliable electrical system protection.
      The Legrand MCB DX3 6000A is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. With a 3-pole configuration, 2A rated current, and D-curve characteristic, this device delivers reliable protection for residential and small commercial electrical systems. It features a 6kA breaking capacity according to IEC60898-1 standard and IP20 finger-safe protection to prevent accidental contact with live parts. The device can be supplied by copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar, offering flexible installation options for various electrical configurations. This circuit-breaker is equipped with two DIN rail clamps (top and bottom) allowing independent removal while the prong busbar remains in place. The MCB DX3 includes a convenient label holder for clear circuit identification and status indication with ON/OFF markings on the handle in green and red backgrounds respectively. It can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and accessories for enhanced functionality and customization. The device complies with substance-restriction requirements and has been designed with environmental consciousness in mind. With a rated voltage of 400V AC, rated insulation voltage of 500V, and rated impulse withstand voltage of 4kV, this MCB provides comprehensive protection across multiple electrical parameters. The tripping threshold in case of short-circuit ranges between 20A and 28A (D curve between 10 In and 14 In), ensuring optimal protection without nuisance trips. Suitable for connectable conductor cross-sections from 1.5-35mm² (solid-core) and 1.5-25mm² (multi-wired), this device accommodates various cable types and installation requirements.

      Key Features

      • 6kA breaking capacity according to IEC 60898-1 standard for household installations
      • D-curve tripping characteristic with short-circuit threshold between 20A and 28A (10-14 In)
      • IP20 finger-safe protection against solid bodies larger than 12.5mm per IEC/EN 60529
      • Compatible with copper cable, prong busbar, fork busbar, and Legrand HX3 plug busbar
      • Dual DIN rail clamps allowing independent removal while busbar remains in place
      • Label holder for clear circuit identification with ON/OFF status indication
      • Compatible with Legrand DX3 auxiliaries, RCD add-on modules, and accessories
      • Supports aluminum cable with terminal accessory connection
      • Halogen-free design with environmentally conscious manufacturing process
      • Wide operating temperature range from -25°C to +70°C

      Technical Specifications

      Specification Value
      Product NameMCB DX3 6000A 3 Pole 2A Curve D
      Reference Number408082
      EAN Code3245064080828
      Number of Poles3 poles (3P)
      Rated Current2 A
      Release CharacteristicD-curve
      Rated Voltage400 V AC
      Rated Insulation Voltage500 V
      Rated Impulse Withstand Voltage4 kV
      Voltage TypeAC (Alternating Current)
      Breaking Capacity IEC 608986 kA at 400V
      Breaking Capacity IEC 60947-2 (230V)25 kA
      Breaking Capacity IEC 60947-2 (400V)10 kA
      Frequency Range50-60 Hz
      Degree of ProtectionIP20 (Finger-safe)
      Degree of Impact StrengthIK02
      Built-in Depth44 mm
      Width53.1 mm
      Height94.8 mm
      Overall Depth77.8 mm
      Modular Width3 modular spacings
      Connectable Conductor Cross-Section (Solid-Core)1.5-35 mm²
      Connectable Conductor Cross-Section (Multi-Wired)1.5-25 mm²
      Connection TypeScrewed terminal
      Mounting MethodDIN rail
      Operating Temperature Range-25°C to +70°C
      Storage Temperature Range-40°C to +70°C
      Pollution Degree2
      ColourGrey
      RAL Number7035
      Halogen FreeYes
      Flush-Mounted InstallationYes
      Concurrently Switching NeutralNo
      Additional Equipment PossibleYes
      Explosion-ProofNo
      Label Space/Information SurfaceYes
      Supply DirectionBy the top or bottom
      Carbon Footprint (Manufacturing Phase)3.192 kg CO₂ eq.