Description

Shop Legrand Three-Phase Hospital Isolating Transformer 400V 230V 10kVA | 42585 In Iraq Best Prices

Advanced three-phase isolating transformer for hospitals with 10kVA output, IEC EN 61558-2-15 compliance, integrated temperature monitoring, electrostatic shield, and superior safety features for critical medical applications.
The Legrand Isolating Transformer for Hospitals is a three-phase transformer designed to meet the stringent safety requirements of medical facilities. Conforming to IEC EN 61558-2-15 standards, this transformer provides reliable power isolation and protection in hospital environments. With a primary voltage of 400V and secondary voltage of 230V, it delivers 10kVA of rated power suitable for critical medical applications. This transformer features an advanced electrostatic shield connected to a dedicated terminal, ensuring superior electromagnetic compatibility and safety. The integrated temperature monitoring system with bi-metal strips provides automatic protection against overheating, with outputs available for connection to control systems for optical or acoustic alerts. The secondary/earth leakage current is limited to just 0.5mA off-load, meeting the most demanding safety standards for hospital use. The unit is equipped with flexible cable terminals rated at 16mm² for primary connections and 35mm² for secondary connections, ensuring robust and reliable electrical connections. With IP21 protection rating and IK08 impact strength, this transformer is built to withstand the demanding conditions of hospital environments. The YY wiring system and H-class insulation material provide excellent thermal performance and longevity.

Key Features

  • Conforms to IEC EN 61558-2-15 standard for hospital isolating transformers
  • Integrated temperature monitoring system with bi-metal strips for automatic overload protection
  • Electrostatic shield connected to dedicated terminal for superior electromagnetic compatibility
  • Secondary/earth leakage current limited to 0.5mA off-load for maximum safety
  • Inrush current limited to 12 times peak primary current value for equipment protection
  • YY wiring system with H-class insulation material for excellent thermal performance
  • IP21 protection rating and IK08 impact strength for demanding hospital environments
  • Flexible cable terminals: 16mm² primary, 35mm² secondary for robust connections
  • Outputs available for connection to optical or acoustic control systems
  • Three-phase power distribution: 400V primary to 230V secondary conversion

Technical Specifications

Specification Value
Product TypeThree-Phase Isolating Transformer for Hospitals
ManufacturerLegrand
Reference Number042585
EAN Code3245060425852
Primary Voltage400V~ + Neutral (AC)
Secondary Voltage230V~ + Neutral (AC)
Rated Power Output10 kVA
Wiring SystemYY (Star-Star)
Insulation Material ClassH (180°C)
Relative Short Circuit Voltage2.7%
Secondary/Earth Leakage Current0.5 mA (off-load)
Inrush CurrentLimited to 12 times peak primary current
IP Protection RatingIP21
Impact Strength RatingIK08
Primary Terminal Cable16 mm² flexible cable
Secondary Terminal Cable35 mm² flexible cable
Connection TypeScrewed Terminal
Width470 mm
Height410 mm
Depth340 mm
Temperature MonitoringBi-metal strips with control system outputs
Electrostatic ShieldYes, connected to dedicated terminal
Short-Circuit ProofNo
Terminal MarkingYes
Safety StandardIEC EN 61558-2-15
ApplicationHospital and Medical Facilities

Order Legrand Three-Phase Hospital Isolating Transformer 400V 230V 10kVA | 42585 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand Three-Phase Hospital Isolating Transformer 400V 230V 10kVA | 42585

    SKU: 042585

      Description

      Shop Legrand Three-Phase Hospital Isolating Transformer 400V 230V 10kVA | 42585 In Iraq Best Prices

      Advanced three-phase isolating transformer for hospitals with 10kVA output, IEC EN 61558-2-15 compliance, integrated temperature monitoring, electrostatic shield, and superior safety features for critical medical applications.
      The Legrand Isolating Transformer for Hospitals is a three-phase transformer designed to meet the stringent safety requirements of medical facilities. Conforming to IEC EN 61558-2-15 standards, this transformer provides reliable power isolation and protection in hospital environments. With a primary voltage of 400V and secondary voltage of 230V, it delivers 10kVA of rated power suitable for critical medical applications. This transformer features an advanced electrostatic shield connected to a dedicated terminal, ensuring superior electromagnetic compatibility and safety. The integrated temperature monitoring system with bi-metal strips provides automatic protection against overheating, with outputs available for connection to control systems for optical or acoustic alerts. The secondary/earth leakage current is limited to just 0.5mA off-load, meeting the most demanding safety standards for hospital use. The unit is equipped with flexible cable terminals rated at 16mm² for primary connections and 35mm² for secondary connections, ensuring robust and reliable electrical connections. With IP21 protection rating and IK08 impact strength, this transformer is built to withstand the demanding conditions of hospital environments. The YY wiring system and H-class insulation material provide excellent thermal performance and longevity.

      Key Features

      • Conforms to IEC EN 61558-2-15 standard for hospital isolating transformers
      • Integrated temperature monitoring system with bi-metal strips for automatic overload protection
      • Electrostatic shield connected to dedicated terminal for superior electromagnetic compatibility
      • Secondary/earth leakage current limited to 0.5mA off-load for maximum safety
      • Inrush current limited to 12 times peak primary current value for equipment protection
      • YY wiring system with H-class insulation material for excellent thermal performance
      • IP21 protection rating and IK08 impact strength for demanding hospital environments
      • Flexible cable terminals: 16mm² primary, 35mm² secondary for robust connections
      • Outputs available for connection to optical or acoustic control systems
      • Three-phase power distribution: 400V primary to 230V secondary conversion

      Technical Specifications

      Specification Value
      Product TypeThree-Phase Isolating Transformer for Hospitals
      ManufacturerLegrand
      Reference Number042585
      EAN Code3245060425852
      Primary Voltage400V~ + Neutral (AC)
      Secondary Voltage230V~ + Neutral (AC)
      Rated Power Output10 kVA
      Wiring SystemYY (Star-Star)
      Insulation Material ClassH (180°C)
      Relative Short Circuit Voltage2.7%
      Secondary/Earth Leakage Current0.5 mA (off-load)
      Inrush CurrentLimited to 12 times peak primary current
      IP Protection RatingIP21
      Impact Strength RatingIK08
      Primary Terminal Cable16 mm² flexible cable
      Secondary Terminal Cable35 mm² flexible cable
      Connection TypeScrewed Terminal
      Width470 mm
      Height410 mm
      Depth340 mm
      Temperature MonitoringBi-metal strips with control system outputs
      Electrostatic ShieldYes, connected to dedicated terminal
      Short-Circuit ProofNo
      Terminal MarkingYes
      Safety StandardIEC EN 61558-2-15
      ApplicationHospital and Medical Facilities

      Order Legrand Three-Phase Hospital Isolating Transformer 400V 230V 10kVA | 42585 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.


      • خيارت شحن متعددة محلية ودولية

      • ماركات عالمية أصلية

      • طرق الدفع الموجودة 100% أمنه

      • دعم 24 ساعة فى اليوم

      منتجات تم مشاهدتها

      © 2026 TOOLMART

          Login

          Forgot your password?

          Don't have an account yet?
          Create account