Premium 3-pole thermal-magnetic circuit breaker with 6000A breaking capacity, 32A rated current, B-curve protection, IP20 rating, and DIN rail mounting for reliable electrical system protection in residential and commercial installations.
The Legrand MCB TX3 6000A is a premium thermal-magnetic circuit breaker designed to protect residential and small commercial wiring installations against overloads and short circuits. This 3-pole device features a rated current of 32A with a B-curve release characteristic, delivering a breaking capacity of 6000A at 400V~. The circuit breaker incorporates advanced protection mechanisms with a tripping threshold between 96A and 160A (B curve between 3 In and 5 In), ensuring precise and reliable isolation of electrical circuits. Built with a current limiting class 3 design, it provides maximum limitation of let-through energy according to IEC 60898-1 standard, making it ideal for applications requiring high reliability and safety.
This MCB is engineered for easy installation on DIN rail mounting systems with a special clamp mechanism that allows independent removal even when fork busbars remain in place. The device is protected against solid bodies larger than 12.5mm with an IP20 rating according to IEC/EN 60529 standard. It features a convenient label holder for circuit identification and clear ON/OFF indication printed on the handle with red and green backgrounds for easy status identification. The thermal-magnetic design ensures precise tripping under fault conditions while maintaining immunity to normal electrical transients.
The TX3 6000A can be supplied via copper cable, prong busbar (top or bottom side), or fork busbar (bottom side), offering flexible installation options. It can be equipped with Legrand DX3 auxiliaries and accessories for enhanced functionality, and is compatible with aluminium cables using Legrand DX3 terminal accessories. The device complies with substance-restriction requirements and has been designed with environmental consciousness. With a rated insulation voltage of 500V, rated impulse withstand voltage of 4kV, and operation across 50-60Hz frequency range, this circuit breaker meets stringent international safety standards.
Key Features
- 6000A breaking capacity at 400V~ with B-curve 32A rated current for precise circuit protection
- Thermal-magnetic protection mechanism with tripping threshold between 96A and 160A
- Current limiting class 3 design for maximum limitation of let-through energy
- IP20 protection rating with fingerproof design against solid bodies larger than 12.5mm
- DIN rail mounted with special clamp allowing independent removal without disturbing busbars
- Compatible with Legrand DX3 auxiliaries and accessories for enhanced functionality
- Clear ON/OFF indication on handle with red and green background for easy status identification
- Label holder for convenient circuit identification and organization
- Flexible supply options via copper cable, prong busbar, or fork busbar
- Halogen-free construction with environmentally conscious design
Technical Specifications
| Specification |
Value |
| Product Model | MCB TX3 6000A |
| Reference Number | 403405 |
| EAN Code | 3414970387608 |
| Manufacturer | Legrand |
| Number of Poles | 3 poles (3P) |
| Rated Current | 32 A |
| Release Characteristic | B-curve |
| Breaking Capacity at 400V | 6 kA |
| Breaking Capacity at 230V | 10 kA |
| Rated Voltage | 400 V |
| Nominal Voltage Range | 240-415 V |
| Rated Insulation Voltage | 500 V |
| Rated Impulse Withstand Voltage | 4 kV |
| Voltage Type | AC |
| Frequency Range | 50-60 Hz |
| Current Limiting Class | Class 3 |
| Tripping Threshold | 96A to 160A (B curve between 3 In and 5 In) |
| Degree of Protection | IP20 (fingerproof) |
| Degree of Impact Strength | IK02 |
| Width in Modular Spacings | 3 modules |
| Width | 53.1 mm |
| Height | 88 mm |
| Depth | 77.8 mm |
| Built-in Depth | 44 mm |
| Colour | Grey (RAL 7035) |
| Mounting Method | DIN rail |
| Connection Type | Screwed terminal, Busbar and cable |
| Electric Supplying Direction | By the top or bottom |
| Pollution Degree | 2 |
| Storage Temperature Range | -40°C to +70°C |
| Flush-mounted Installation | Yes |
| Concurrently Switching Neutral Conductor | No |
| Additional Equipment Possible | Yes (Legrand DX3 auxiliaries and accessories) |
| Label Space/Information Surface | Yes |
| Halogen Free | Yes |
| Explosion-proof | No |
| Number of Protected Poles | 3 |
| Terminal Marking Indication | No |
| Compliance Standard | IEC 60898-1 |