Description

Shop Legrand DX3 MCB 3 Pole 50A Circuit Breaker D Curve | 409504 In Iraq Best Prices

Thermal magnetic circuit-breaker with 10kA breaking capacity, D-curve tripping, 3 poles, 50A rated current, and IP20 protection for reliable electrical installation safety and control.
The Legrand MCB DX3 10000A 3 pole 50A curve D is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits with exceptional reliability. This advanced protection device features a 10kA breaking capacity at 400V and D-curve tripping characteristics, making it ideal for residential and small commercial applications. The DX3 series combines superior performance with user-friendly design, offering both control and isolation capabilities for your electrical installation. This circuit-breaker is engineered with fingerproof protection (IP20) against solid bodies larger than 12.5mm, ensuring safe operation in various environments. It can be supplied through multiple connection methods including copper cables, prong busbars, fork busbars, or Legrand HX3 plug busbars, providing flexible installation options. The device accepts DX3 auxiliaries, RCD add-on modules, and various accessories, allowing for customized configurations to meet specific installation requirements. Features include a label holder for clear circuit identification, on/off indication printed on the handle with red and green backgrounds for easy status identification, and two DIN rail clamps enabling independent removal while the prong busbar remains in place. With halogen-free construction and environmentally conscious design, this MCB complies with substance-restriction requirements and represents Legrand's commitment to sustainable electrical solutions.

Key Features

  • 10kA breaking capacity at 400V with D-curve tripping characteristic between 10-14 In
  • 3-pole configuration with 50A rated current for comprehensive circuit protection
  • Fingerproof IP20 protection against solid bodies larger than 12.5mm
  • Compatible with DX3 auxiliaries, RCD add-on modules and multiple accessories
  • Flexible connection options including copper cables, prong busbars, and Legrand HX3 plug busbars
  • DIN rail mounting with two independent clamps for easy removal
  • Clear circuit identification with label holder and on/off indication
  • Halogen-free construction with environmentally conscious design
  • Operates at 50-60 Hz frequency with 400V rated voltage
  • Accepts aluminium cable connections with terminal accessory compatibility

Technical Specifications

Specification Value
Product TypeThermal Magnetic Circuit-Breaker (MCB)
BrandLegrand
SeriesDX3
Reference Number409504
EAN Code3414970434517
Number of Poles3 poles (total and protected)
Rated Current50 A
Rated Voltage400 V
Rated Insulation Voltage500 V
Rated Impulse Withstand Voltage4 kV
Release CharacteristicD-curve (tripping between 10-14 In)
Breaking Capacity at 230V16 kA (Icn according to EN 60898)
Breaking Capacity at 400V10 kA (Icn according to EN 60898)
Ultimate Breaking Capacity at 230V32 kA (Icu according to IEC 60947-2)
Ultimate Breaking Capacity at 400V16 kA (Icu according to IEC 60947-2)
Frequency Range50-60 Hz
Voltage TypeAC (Alternating Current)
Degree of ProtectionIP20 (Fingerproof)
Degree of Impact StrengthIK02
Built-in Depth44 mm
Width in Modular Spacings3 modules
Width53.1 mm
Height94.8 mm
Depth77.8 mm
ColorGrey (RAL 7035)
Connection TypeScrewed Terminal
Connectable Conductor Cross Section (Solid-core)1.5-35 mm²
Connectable Conductor Cross Section (Multi-wired)1.5-25 mm²
Mounting MethodDIN Rail
Electric Supplying DirectionBy the top or bottom
Flush-mounted InstallationYes
Concurrently Switching Neutral ConductorNo
Pollution Degree2
Ambient Temperature (Operating)-25 to 70 °C
Storage Temperature-40 to 70 °C
Additional Equipment PossibleYes
Halogen FreeYes
Explosion-proofNo
Label Space/Information SurfaceYes
Carbon Footprint (Manufacturing Phase)2.722 kg CO2 eq.
Standards ComplianceIEC 60898-1, EN 60898, IEC 60947-2, IEC/EN 60529

Order Legrand DX3 MCB 3 Pole 50A Circuit Breaker D Curve | 409504 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand DX3 MCB 3 Pole 50A Circuit Breaker D Curve | 409504

    SKU: 409504

      Description

      Shop Legrand DX3 MCB 3 Pole 50A Circuit Breaker D Curve | 409504 In Iraq Best Prices

      Thermal magnetic circuit-breaker with 10kA breaking capacity, D-curve tripping, 3 poles, 50A rated current, and IP20 protection for reliable electrical installation safety and control.
      The Legrand MCB DX3 10000A 3 pole 50A curve D is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits with exceptional reliability. This advanced protection device features a 10kA breaking capacity at 400V and D-curve tripping characteristics, making it ideal for residential and small commercial applications. The DX3 series combines superior performance with user-friendly design, offering both control and isolation capabilities for your electrical installation. This circuit-breaker is engineered with fingerproof protection (IP20) against solid bodies larger than 12.5mm, ensuring safe operation in various environments. It can be supplied through multiple connection methods including copper cables, prong busbars, fork busbars, or Legrand HX3 plug busbars, providing flexible installation options. The device accepts DX3 auxiliaries, RCD add-on modules, and various accessories, allowing for customized configurations to meet specific installation requirements. Features include a label holder for clear circuit identification, on/off indication printed on the handle with red and green backgrounds for easy status identification, and two DIN rail clamps enabling independent removal while the prong busbar remains in place. With halogen-free construction and environmentally conscious design, this MCB complies with substance-restriction requirements and represents Legrand's commitment to sustainable electrical solutions.

      Key Features

      • 10kA breaking capacity at 400V with D-curve tripping characteristic between 10-14 In
      • 3-pole configuration with 50A rated current for comprehensive circuit protection
      • Fingerproof IP20 protection against solid bodies larger than 12.5mm
      • Compatible with DX3 auxiliaries, RCD add-on modules and multiple accessories
      • Flexible connection options including copper cables, prong busbars, and Legrand HX3 plug busbars
      • DIN rail mounting with two independent clamps for easy removal
      • Clear circuit identification with label holder and on/off indication
      • Halogen-free construction with environmentally conscious design
      • Operates at 50-60 Hz frequency with 400V rated voltage
      • Accepts aluminium cable connections with terminal accessory compatibility

      Technical Specifications

      Specification Value
      Product TypeThermal Magnetic Circuit-Breaker (MCB)
      BrandLegrand
      SeriesDX3
      Reference Number409504
      EAN Code3414970434517
      Number of Poles3 poles (total and protected)
      Rated Current50 A
      Rated Voltage400 V
      Rated Insulation Voltage500 V
      Rated Impulse Withstand Voltage4 kV
      Release CharacteristicD-curve (tripping between 10-14 In)
      Breaking Capacity at 230V16 kA (Icn according to EN 60898)
      Breaking Capacity at 400V10 kA (Icn according to EN 60898)
      Ultimate Breaking Capacity at 230V32 kA (Icu according to IEC 60947-2)
      Ultimate Breaking Capacity at 400V16 kA (Icu according to IEC 60947-2)
      Frequency Range50-60 Hz
      Voltage TypeAC (Alternating Current)
      Degree of ProtectionIP20 (Fingerproof)
      Degree of Impact StrengthIK02
      Built-in Depth44 mm
      Width in Modular Spacings3 modules
      Width53.1 mm
      Height94.8 mm
      Depth77.8 mm
      ColorGrey (RAL 7035)
      Connection TypeScrewed Terminal
      Connectable Conductor Cross Section (Solid-core)1.5-35 mm²
      Connectable Conductor Cross Section (Multi-wired)1.5-25 mm²
      Mounting MethodDIN Rail
      Electric Supplying DirectionBy the top or bottom
      Flush-mounted InstallationYes
      Concurrently Switching Neutral ConductorNo
      Pollution Degree2
      Ambient Temperature (Operating)-25 to 70 °C
      Storage Temperature-40 to 70 °C
      Additional Equipment PossibleYes
      Halogen FreeYes
      Explosion-proofNo
      Label Space/Information SurfaceYes
      Carbon Footprint (Manufacturing Phase)2.722 kg CO2 eq.
      Standards ComplianceIEC 60898-1, EN 60898, IEC 60947-2, IEC/EN 60529