Description

Shop Legrand Isolating Transformer Hospital IP21 Single Phase 4kVA | 42572 In Iraq Best Prices

Hospital-grade isolating transformer with IP21 protection, dual temperature monitoring, 4kVA single-phase output, and full IEC EN 61558-2-15 compliance for medical environments.
The Legrand Isolating Transformer for Hospitals is a specialized single-phase transformer designed specifically for medical environments, conforming to the stringent requirements of IEC EN 61558-2-15 standard. This transformer features an IP21 degree of protection and is equipped with dual temperature monitoring systems including bi-metal strips and thermocouple PT100 sensors, making it fully compatible with any medical control system. The primary and secondary voltages are both 230V with a center tap configuration, providing reliable 4kVA output power. This isolating transformer incorporates advanced safety features essential for hospital applications, including an electrostatic shield connected to a dedicated terminal and secondary/earth leakage current limited to 0.5mA off-load. The inrush current is carefully controlled to 12 times the peak value of primary current, ensuring safe operation in sensitive medical equipment environments. Both primary and secondary terminals feature flexible cables rated at 16mm² for secure connections. The transformer meets all medical facility requirements with its robust construction, safety certifications, and comprehensive monitoring capabilities. Its compact dimensions (340mm width x 410mm height x 370mm depth) and Type H insulation material ensure optimal performance and longevity in demanding healthcare settings. The device is built as a true isolating transformer with a relative short-circuit voltage of 3.2%, providing excellent protection for critical medical applications.

Key Features

  • IEC EN 61558-2-15 compliant isolating transformer for hospital applications
  • Dual temperature monitoring system with bi-metal strips and PT100 thermocouple sensors
  • IP21 degree of protection for secure operation in medical environments
  • Secondary/earth leakage current limited to 0.5mA for enhanced safety
  • Electrostatic shield connected to dedicated terminal for EMI protection
  • 4kVA rated apparent power with stable 230V primary and secondary voltages
  • Type H insulation material for superior thermal performance
  • Controlled inrush current at 12 times peak primary current value
  • Center tap secondary configuration for flexible voltage options
  • 16mm² flexible cable terminals for secure primary and secondary connections

Technical Specifications

Specification Value
Product TypeIsolating Transformer for Hospitals
Phase ConfigurationSingle-phase
Primary Voltage230V AC
Secondary Voltage230V AC with center tap
Rated Apparent Power4000 VA (4 kVA)
Degree of ProtectionIP21
Insulation TypeType H
Secondary/Earth Leakage Current0.5 mA (off-load)
Inrush Current12 times peak primary current value
Relative Short-Circuit Voltage3.2%
Primary Terminal Cable16 mm² flexible cable
Secondary Terminal Cable16 mm² flexible cable
Temperature MonitoringDual system with bi-metal strips and PT100 thermocouple
Electrostatic ShieldYes, connected to dedicated terminal
Width340 mm
Height410 mm
Depth370 mm
Safety StandardIEC EN 61558-2-15
Ring CoreNo
PCB Mounting CompatibleNo
Distribution Board MountingNo
Short-Circuit ProofNo
Reference Number042572
EAN Code3245060425722
ManufacturerLegrand

Order Legrand Isolating Transformer Hospital IP21 Single Phase 4kVA | 42572 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand Isolating Transformer Hospital IP21 Single Phase 4kVA | 42572

    SKU: 042572

      Description

      Shop Legrand Isolating Transformer Hospital IP21 Single Phase 4kVA | 42572 In Iraq Best Prices

      Hospital-grade isolating transformer with IP21 protection, dual temperature monitoring, 4kVA single-phase output, and full IEC EN 61558-2-15 compliance for medical environments.
      The Legrand Isolating Transformer for Hospitals is a specialized single-phase transformer designed specifically for medical environments, conforming to the stringent requirements of IEC EN 61558-2-15 standard. This transformer features an IP21 degree of protection and is equipped with dual temperature monitoring systems including bi-metal strips and thermocouple PT100 sensors, making it fully compatible with any medical control system. The primary and secondary voltages are both 230V with a center tap configuration, providing reliable 4kVA output power. This isolating transformer incorporates advanced safety features essential for hospital applications, including an electrostatic shield connected to a dedicated terminal and secondary/earth leakage current limited to 0.5mA off-load. The inrush current is carefully controlled to 12 times the peak value of primary current, ensuring safe operation in sensitive medical equipment environments. Both primary and secondary terminals feature flexible cables rated at 16mm² for secure connections. The transformer meets all medical facility requirements with its robust construction, safety certifications, and comprehensive monitoring capabilities. Its compact dimensions (340mm width x 410mm height x 370mm depth) and Type H insulation material ensure optimal performance and longevity in demanding healthcare settings. The device is built as a true isolating transformer with a relative short-circuit voltage of 3.2%, providing excellent protection for critical medical applications.

      Key Features

      • IEC EN 61558-2-15 compliant isolating transformer for hospital applications
      • Dual temperature monitoring system with bi-metal strips and PT100 thermocouple sensors
      • IP21 degree of protection for secure operation in medical environments
      • Secondary/earth leakage current limited to 0.5mA for enhanced safety
      • Electrostatic shield connected to dedicated terminal for EMI protection
      • 4kVA rated apparent power with stable 230V primary and secondary voltages
      • Type H insulation material for superior thermal performance
      • Controlled inrush current at 12 times peak primary current value
      • Center tap secondary configuration for flexible voltage options
      • 16mm² flexible cable terminals for secure primary and secondary connections

      Technical Specifications

      Specification Value
      Product TypeIsolating Transformer for Hospitals
      Phase ConfigurationSingle-phase
      Primary Voltage230V AC
      Secondary Voltage230V AC with center tap
      Rated Apparent Power4000 VA (4 kVA)
      Degree of ProtectionIP21
      Insulation TypeType H
      Secondary/Earth Leakage Current0.5 mA (off-load)
      Inrush Current12 times peak primary current value
      Relative Short-Circuit Voltage3.2%
      Primary Terminal Cable16 mm² flexible cable
      Secondary Terminal Cable16 mm² flexible cable
      Temperature MonitoringDual system with bi-metal strips and PT100 thermocouple
      Electrostatic ShieldYes, connected to dedicated terminal
      Width340 mm
      Height410 mm
      Depth370 mm
      Safety StandardIEC EN 61558-2-15
      Ring CoreNo
      PCB Mounting CompatibleNo
      Distribution Board MountingNo
      Short-Circuit ProofNo
      Reference Number042572
      EAN Code3245060425722
      ManufacturerLegrand

      Order Legrand Isolating Transformer Hospital IP21 Single Phase 4kVA | 42572 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.


      • خيارت شحن متعددة محلية ودولية

      • ماركات عالمية أصلية

      • طرق الدفع الموجودة 100% أمنه

      • دعم 24 ساعة فى اليوم

      منتجات تم مشاهدتها

      © 2026 TOOLMART

          Login

          Forgot your password?

          Don't have an account yet?
          Create account