Shop Legrand IP21 Single-Phase Isolating Transformer Hospital 2.5kVA | 42571 In Iraq Best Prices
Hospital-grade isolating transformer with IP21 protection, dual temperature monitoring, 2.5kVA capacity, and IEC EN 61558-2-15 compliance for critical medical applications.
This Legrand isolating transformer is specifically designed for hospital environments and complies with the stringent requirements of IEC EN 61558-2-15 standard. The transformer features advanced safety characteristics including secondary/earth leakage current limited to 0.5 mA off-load and inrush current limited to 12 times the peak value of primary current. It is equipped with a dedicated electrostatic shield linked to a dedicated terminal, ensuring maximum electrical safety for critical medical applications.
The transformer incorporates dual temperature monitoring systems consisting of bi-metal strips and thermocouple PT 100 sensors, making it fully compatible with any medical control system. With a rated apparent power of 2.5 kVA, primary voltage of 230V, and secondary voltage of 230V with centre tap, this transformer provides reliable power distribution for sensitive hospital equipment. The IP21 protection rating ensures protection against direct contact and water splashes, making it suitable for various hospital environments.
The unit features flexible cable terminals with 16 mm² cross-section on both primary and secondary sides, ensuring safe and secure connections. Constructed with Type B insulation material according to IEC 85 standards, this transformer delivers exceptional performance and durability. Its compact dimensions of 320mm width, 330mm height, and 253mm depth make it suitable for installation in standard distribution configurations. The transformer's 3.1% relative short circuit voltage ensures stable operation and protection against voltage fluctuations.
Key Features
- IEC EN 61558-2-15 compliant isolating transformer for hospital applications
- Dual temperature monitoring systems with bi-metal strips and PT100 thermocouple sensors
- Secondary/earth leakage current limited to 0.5 mA off-load for enhanced safety
- Inrush current protection limited to 12 times peak primary current value
- Electrostatic shield with dedicated terminal connection for electromagnetic protection
- IP21 protection rating against direct contact and water splashes
- 2.5 kVA rated apparent power for reliable medical equipment operation
- Type B insulation material per IEC 85 standards for optimal performance
- 230V primary to 230V secondary with centre tap configuration
- Flexible cable terminals with 16 mm² cross-section for secure connections
Technical Specifications
| Specification |
Value |
| Product Type | Single-Phase Isolating Transformer |
| Standard Compliance | IEC EN 61558-2-15 |
| Rated Apparent Power | 2.5 kVA |
| Primary Voltage | 230V~ |
| Secondary Voltage | 230V~ with centre tap |
| Voltage Range (Min-Max) | 230-230V |
| Protection Rating | IP21 |
| Insulation Material Type | Type B (IEC 85) |
| Secondary/Earth Leakage Current | 0.5 mA off-load (maximum) |
| Inrush Current Limitation | 12 times peak primary current |
| Relative Short Circuit Voltage | 3.1% |
| Primary Cable Terminal | Flexible cable 16 mm² |
| Secondary Cable Terminal | Flexible cable 16 mm² |
| Temperature Monitoring System | Dual system: Bi-metal strips and PT100 thermocouple |
| Width | 320 mm |
| Height | 330 mm |
| Depth | 253 mm |
| Electrostatic Shield | Yes, with dedicated terminal |
| Ring Core | No |
| PCB Mounting Compatible | No |
| Distribution Board Mounting | No |
| Short-Circuit Proof | No |
| Reference Number | 042571 |
| EAN Code | 3245060425715 |