Description

Shop Legrand DX3 MCB 4 Pole 20A Circuit Breaker C Curve | 407929 In Iraq Best Prices

Legrand DX3 4-pole 20A thermal magnetic circuit breaker with C curve, 6kA/10kA breaking capacity, IP20 fingerproof protection, and DIN rail mounting for residential and commercial electrical installations.
The Legrand DX3 MCB 6000A is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. This 4-pole device features a 20A rated current with C curve characteristics and operates at 400V~ with a breaking capacity of 6kA/10kA. The circuit breaker is equipped with IP20 "fingerproof" safety protection, preventing accidental contact with live components. It can be supplied by copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar from either the top or bottom side, providing flexible installation options for residential and small commercial applications. This MCB offers maximum energy limitation with class 3 current limiting capability according to IEC 60898-1 standard. The device features a tripping threshold between 100A and 200A for short-circuit protection, providing reliable protection for circuits up to 20A. It is compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories, allowing for customized protection solutions. The circuit breaker features a convenient label holder for circuit identification and clear on/off indication with red and green backgrounds on the handle for easy status recognition. The product is halogen-free and designed with environmental consciousness, complying with substance-restriction requirements including RoHS and REACH directives. With a built-in depth of 44mm and mounting width of 4 modular spacings (70.8mm), it fits standard DIN rail installations. The device operates reliably in ambient temperatures from -25°C to 70°C and features independent removal capability with dual DIN rail clamps, making maintenance and replacement straightforward.

Key Features

  • Thermal magnetic protection against overloads and short-circuits with C curve characteristics
  • 4-pole configuration with 20A rated current and 400V~ operating voltage
  • High breaking capacity of 6kA according to IEC 60898-1 and 10kA according to IEC 60947-2
  • IP20 fingerproof safety protection preventing accidental contact with live components
  • Class 3 current limiting capability with maximum energy limitation
  • Compatible with Legrand DX3 auxiliaries, RCD add-on modules and accessories
  • Flexible supply options: copper cable, prong busbar, fork busbar, or HX3 plug busbar
  • Convenient label holder for circuit identification and clear on/off indication
  • Independent removal capability with dual DIN rail clamps for easy maintenance
  • Halogen-free design with environmental consciousness and RoHS/REACH compliance

Technical Specifications

Specification Value
Product TypeThermal Magnetic Circuit Breaker (MCB)
Number of Poles4 poles
Rated Current20 A
Release CharacteristicC curve (tripping threshold 100-200A)
Rated Voltage400 V AC
Rated Insulation Voltage500 V
Rated Impulse Withstand Voltage4 kV
Breaking Capacity (Icn) at 400V6 kA according to EN 60898
Breaking Capacity (Icu) at 230V25 kA according to IEC 60947-2
Breaking Capacity (Icu) at 400V10 kA according to IEC 60947-2
Current Limiting ClassClass 3
Degree of ProtectionIP20 (fingerproof)
Degree of Impact StrengthIK02
Built-in Depth44 mm
Width in Modular Spacings4 spacings
Dimensions (W x H x D)70.8 x 94.8 x 77.8 mm
Connectable Conductor Cross Section (Multi-wired)1.5-25 mm²
Connectable Conductor Cross Section (Solid-core)1.5-35 mm²
Connection TypeScrewed terminal
Mounting MethodDIN rail
Frequency50-60 Hz
Operating Temperature Range-25 to +70°C
Storage Temperature Range-40 to +70°C
Pollution Degree2
ColorGrey (RAL 7035)
Halogen FreeYes
Neutral Conductor SwitchingYes - concurrently switching
Supply DirectionTop or bottom
Additional Equipment PossibleYes - RCD add-on modules and auxiliaries
Reference Number407929
EAN Code3245064079297
Carbon Footprint (Manufacturing)3.412 kg CO₂ eq.

Order Legrand DX3 MCB 4 Pole 20A Circuit Breaker C Curve | 407929 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand DX3 MCB 4 Pole 20A Circuit Breaker C Curve | 407929

    SKU: 407929

      Description

      Shop Legrand DX3 MCB 4 Pole 20A Circuit Breaker C Curve | 407929 In Iraq Best Prices

      Legrand DX3 4-pole 20A thermal magnetic circuit breaker with C curve, 6kA/10kA breaking capacity, IP20 fingerproof protection, and DIN rail mounting for residential and commercial electrical installations.
      The Legrand DX3 MCB 6000A is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. This 4-pole device features a 20A rated current with C curve characteristics and operates at 400V~ with a breaking capacity of 6kA/10kA. The circuit breaker is equipped with IP20 "fingerproof" safety protection, preventing accidental contact with live components. It can be supplied by copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar from either the top or bottom side, providing flexible installation options for residential and small commercial applications. This MCB offers maximum energy limitation with class 3 current limiting capability according to IEC 60898-1 standard. The device features a tripping threshold between 100A and 200A for short-circuit protection, providing reliable protection for circuits up to 20A. It is compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories, allowing for customized protection solutions. The circuit breaker features a convenient label holder for circuit identification and clear on/off indication with red and green backgrounds on the handle for easy status recognition. The product is halogen-free and designed with environmental consciousness, complying with substance-restriction requirements including RoHS and REACH directives. With a built-in depth of 44mm and mounting width of 4 modular spacings (70.8mm), it fits standard DIN rail installations. The device operates reliably in ambient temperatures from -25°C to 70°C and features independent removal capability with dual DIN rail clamps, making maintenance and replacement straightforward.

      Key Features

      • Thermal magnetic protection against overloads and short-circuits with C curve characteristics
      • 4-pole configuration with 20A rated current and 400V~ operating voltage
      • High breaking capacity of 6kA according to IEC 60898-1 and 10kA according to IEC 60947-2
      • IP20 fingerproof safety protection preventing accidental contact with live components
      • Class 3 current limiting capability with maximum energy limitation
      • Compatible with Legrand DX3 auxiliaries, RCD add-on modules and accessories
      • Flexible supply options: copper cable, prong busbar, fork busbar, or HX3 plug busbar
      • Convenient label holder for circuit identification and clear on/off indication
      • Independent removal capability with dual DIN rail clamps for easy maintenance
      • Halogen-free design with environmental consciousness and RoHS/REACH compliance

      Technical Specifications

      Specification Value
      Product TypeThermal Magnetic Circuit Breaker (MCB)
      Number of Poles4 poles
      Rated Current20 A
      Release CharacteristicC curve (tripping threshold 100-200A)
      Rated Voltage400 V AC
      Rated Insulation Voltage500 V
      Rated Impulse Withstand Voltage4 kV
      Breaking Capacity (Icn) at 400V6 kA according to EN 60898
      Breaking Capacity (Icu) at 230V25 kA according to IEC 60947-2
      Breaking Capacity (Icu) at 400V10 kA according to IEC 60947-2
      Current Limiting ClassClass 3
      Degree of ProtectionIP20 (fingerproof)
      Degree of Impact StrengthIK02
      Built-in Depth44 mm
      Width in Modular Spacings4 spacings
      Dimensions (W x H x D)70.8 x 94.8 x 77.8 mm
      Connectable Conductor Cross Section (Multi-wired)1.5-25 mm²
      Connectable Conductor Cross Section (Solid-core)1.5-35 mm²
      Connection TypeScrewed terminal
      Mounting MethodDIN rail
      Frequency50-60 Hz
      Operating Temperature Range-25 to +70°C
      Storage Temperature Range-40 to +70°C
      Pollution Degree2
      ColorGrey (RAL 7035)
      Halogen FreeYes
      Neutral Conductor SwitchingYes - concurrently switching
      Supply DirectionTop or bottom
      Additional Equipment PossibleYes - RCD add-on modules and auxiliaries
      Reference Number407929
      EAN Code3245064079297
      Carbon Footprint (Manufacturing)3.412 kg CO₂ eq.

      Order Legrand DX3 MCB 4 Pole 20A Circuit Breaker C Curve | 407929 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.


      • خيارت شحن متعددة محلية ودولية

      • ماركات عالمية أصلية

      • طرق الدفع الموجودة 100% أمنه

      • دعم 24 ساعة فى اليوم

      منتجات تم مشاهدتها

      © 2026 TOOLMART

          Login

          Forgot your password?

          Don't have an account yet?
          Create account