Shop Legrand DX3 MCB 3P 13A Curve B 6000A Circuit Breaker | 407560 In Iraq Best Prices

3-pole 13A thermal magnetic circuit-breaker with 6kA breaking capacity, B-curve characteristic, IP20 protection, and DIN rail mounting for reliable electrical installation protection.
The Legrand DX3 MCB 6000A is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. This 3-pole, 13A rated device operates at 400V AC with a B-curve characteristic and provides a breaking capacity of 6kA according to IEC 60898-1 standard for household installations. The circuit-breaker features a tripping threshold for short-circuits between 39A and 65A (B curve between 3 In and 5 In), ensuring reliable and precise disconnection when electrical faults occur. This MCB is equipped with two DIN rail clamps (one on top and one on bottom) allowing independent removal even when the prong busbar supplying the row remains in place. The device is protected against solid bodies larger than 12.5mm with an IP20 rating according to IEC/EN 60529 standard. It achieves the maximum level of limitation of let-through energy with energy limitation class 3 according to IEC 60898-1 standard. The product accepts DX³ auxiliaries, RCD add-on modules, and accessories, making it highly versatile for various electrical installations. The circuit-breaker can be supplied by copper cable, prong busbar (top or bottom side), fork busbar (bottom side), or Legrand HX3 plug busbar (top side). It features a label holder for clear circuit identification and on/off indication printed on the handle with red and green backgrounds for easy status identification. The device complies with substance-restriction requirements and has been designed in an environmentally conscious process, with a carbon footprint of 2.766 kg CO₂ equivalent during the manufacturing phase.

Key Features

  • 3-pole configuration with 13A rated current at 400V AC supply
  • B-curve characteristic with short-circuit tripping between 39A and 65A
  • 6kA breaking capacity according to IEC 60898-1 standard for household installations
  • Energy limitation class 3 for maximum let-through energy limitation
  • IP20 protection against solid bodies larger than 12.5mm
  • Compatible with DX³ auxiliaries, RCD add-on modules and accessories
  • Dual DIN rail clamps for independent removal capability
  • Label holder for circuit identification with on/off status indication
  • Accepts copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar supply
  • Environmentally conscious design with halogen-free construction

Technical Specifications

Specification Value
Product TypeThermal Magnetic Circuit-Breaker (MCB)
Number of Poles3 poles (3P)
Rated Current13 Amperes
Rated Voltage400V AC
Rated Insulation Voltage500V
Rated Impulse Withstand Voltage4 kV
Breaking Capacity (Icn)6 kA at 400V according to EN 60898
Breaking Capacity (Icu)10 kA at 400V according to IEC 60947-2
Breaking Capacity (Icu)25 kA at 230V according to IEC 60947-2
Release CharacteristicB-curve (3 In to 5 In)
Short-Circuit Tripping ThresholdBetween 39A and 65A
Current Limiting ClassClass 3
Degree of ProtectionIP20
Degree of Impact StrengthIK02
Frequency Range50-60 Hz
Operating Temperature Range-25°C to +70°C
Storage Temperature Range-40°C to +70°C
Pollution Degree2
Connectable Conductor Cross Section (Multi-wired)1.5-25 mm²
Connectable Conductor Cross Section (Solid-core)1.5-35 mm²
Connection TypeScrewed Terminal
Width in Modular Spacings3 modules
Width53.1 mm
Height94.8 mm
Depth (Built-in)44 mm
Total Depth77.8 mm
Mounting MethodDIN Rail
ColourGrey
RAL Number7035
Halogen FreeYes
Additional Equipment PossibleYes
Flush-mounted InstallationYes
Concurrently Switching Neutral ConductorNo
Explosion-proofNo
Electric Supplying DirectionTop or Bottom
Label SpaceYes
Carbon Footprint (Manufacturing Phase)2.766 kg CO₂ eq.
Product Reference407560
EAN Code3245064075602
BrandLegrand
SeriesDX³

Order Legrand DX3 MCB 3P 13A Curve B 6000A Circuit Breaker | 407560 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand DX3 MCB 3P 13A Curve B 6000A Circuit Breaker | 407560

    SKU: 407560

      Description

      Shop Legrand DX3 MCB 3P 13A Curve B 6000A Circuit Breaker | 407560 In Iraq Best Prices

      3-pole 13A thermal magnetic circuit-breaker with 6kA breaking capacity, B-curve characteristic, IP20 protection, and DIN rail mounting for reliable electrical installation protection.
      The Legrand DX3 MCB 6000A is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. This 3-pole, 13A rated device operates at 400V AC with a B-curve characteristic and provides a breaking capacity of 6kA according to IEC 60898-1 standard for household installations. The circuit-breaker features a tripping threshold for short-circuits between 39A and 65A (B curve between 3 In and 5 In), ensuring reliable and precise disconnection when electrical faults occur. This MCB is equipped with two DIN rail clamps (one on top and one on bottom) allowing independent removal even when the prong busbar supplying the row remains in place. The device is protected against solid bodies larger than 12.5mm with an IP20 rating according to IEC/EN 60529 standard. It achieves the maximum level of limitation of let-through energy with energy limitation class 3 according to IEC 60898-1 standard. The product accepts DX³ auxiliaries, RCD add-on modules, and accessories, making it highly versatile for various electrical installations. The circuit-breaker can be supplied by copper cable, prong busbar (top or bottom side), fork busbar (bottom side), or Legrand HX3 plug busbar (top side). It features a label holder for clear circuit identification and on/off indication printed on the handle with red and green backgrounds for easy status identification. The device complies with substance-restriction requirements and has been designed in an environmentally conscious process, with a carbon footprint of 2.766 kg CO₂ equivalent during the manufacturing phase.

      Key Features

      • 3-pole configuration with 13A rated current at 400V AC supply
      • B-curve characteristic with short-circuit tripping between 39A and 65A
      • 6kA breaking capacity according to IEC 60898-1 standard for household installations
      • Energy limitation class 3 for maximum let-through energy limitation
      • IP20 protection against solid bodies larger than 12.5mm
      • Compatible with DX³ auxiliaries, RCD add-on modules and accessories
      • Dual DIN rail clamps for independent removal capability
      • Label holder for circuit identification with on/off status indication
      • Accepts copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar supply
      • Environmentally conscious design with halogen-free construction

      Technical Specifications

      Specification Value
      Product TypeThermal Magnetic Circuit-Breaker (MCB)
      Number of Poles3 poles (3P)
      Rated Current13 Amperes
      Rated Voltage400V AC
      Rated Insulation Voltage500V
      Rated Impulse Withstand Voltage4 kV
      Breaking Capacity (Icn)6 kA at 400V according to EN 60898
      Breaking Capacity (Icu)10 kA at 400V according to IEC 60947-2
      Breaking Capacity (Icu)25 kA at 230V according to IEC 60947-2
      Release CharacteristicB-curve (3 In to 5 In)
      Short-Circuit Tripping ThresholdBetween 39A and 65A
      Current Limiting ClassClass 3
      Degree of ProtectionIP20
      Degree of Impact StrengthIK02
      Frequency Range50-60 Hz
      Operating Temperature Range-25°C to +70°C
      Storage Temperature Range-40°C to +70°C
      Pollution Degree2
      Connectable Conductor Cross Section (Multi-wired)1.5-25 mm²
      Connectable Conductor Cross Section (Solid-core)1.5-35 mm²
      Connection TypeScrewed Terminal
      Width in Modular Spacings3 modules
      Width53.1 mm
      Height94.8 mm
      Depth (Built-in)44 mm
      Total Depth77.8 mm
      Mounting MethodDIN Rail
      ColourGrey
      RAL Number7035
      Halogen FreeYes
      Additional Equipment PossibleYes
      Flush-mounted InstallationYes
      Concurrently Switching Neutral ConductorNo
      Explosion-proofNo
      Electric Supplying DirectionTop or Bottom
      Label SpaceYes
      Carbon Footprint (Manufacturing Phase)2.766 kg CO₂ eq.
      Product Reference407560
      EAN Code3245064075602
      BrandLegrand
      SeriesDX³

      Order Legrand DX3 MCB 3P 13A Curve B 6000A Circuit Breaker | 407560 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.


      • خيارت شحن متعددة محلية ودولية

      • ماركات عالمية أصلية

      • طرق الدفع الموجودة 100% أمنه

      • دعم 24 ساعة فى اليوم

      منتجات تم مشاهدتها

      © 2026 TOOLMART

          Login

          Forgot your password?

          Don't have an account yet?
          Create account