Description

Shop Legrand DX3 MCB 3 Pole 10A Circuit Breaker Type D | 408087 In Iraq Best Prices

Professional 3-pole thermal magnetic circuit breaker with 10A rating, 6kA breaking capacity, and advanced D-curve protection for residential and commercial electrical installations
The Legrand DX3 MCB 6000A 3 Pole 10A Curve D is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits with a breaking capacity of 10kA at 400V AC. This modular device features advanced protection mechanisms with a tripping threshold between 100A and 140A for short-circuit protection (D curve between 10 In and 14 In). The circuit breaker can be supplied through multiple connection methods including copper cable, prong busbar (top or bottom side), fork busbar (bottom side), or Legrand HX3 plug busbar (top side), providing flexible installation options for various electrical configurations. This MCB is equipped with comprehensive safety features including IP20 protection rating against solid bodies larger than 12.5mm (fingerproof design) according to IEC/EN 60529 standards. It accepts Legrand DX3 auxiliaries, RCD add-on modules, and various accessories, allowing for system expansion and customization. The device features two independent DIN rail clamps on top and bottom sides, enabling convenient removal while the prong busbar remains in place. It includes a label holder for clear circuit identification and ON/OFF indication printed on the handle with red and green backgrounds for easy status identification. The MCB DX3 complies with substance-restriction requirements and has been designed in an environmentally conscious process with a carbon footprint of 2.885 kg CO2 equivalent during the manufacturing phase. It operates reliably across ambient temperatures from -25°C to 70°C and accepts connectable conductor cross-sections from 1.5-25mm² for multi-wired cables and 1.5-35mm² for solid-core conductors. This professional-grade electrical protection device is rated for 400V AC, 50-60Hz operation and is suitable for residential and small commercial panel installations.

Key Features

  • Breaking capacity of 6kA at 400V AC with 10kA rated short-circuit breaking capacity per IEC 60947-2
  • D-curve protection with tripping threshold between 100A-140A for optimal short-circuit protection
  • IP20 fingerproof design protecting against solid bodies larger than 12.5mm
  • Accepts Legrand DX3 auxiliaries, RCD add-on modules and accessories for system flexibility
  • Independent DIN rail clamps allowing convenient removal without disturbing busbar connections
  • Clear circuit identification with label holder and ON/OFF status indication on handle
  • Environmentally conscious design with halogen-free construction and low carbon footprint
  • Multiple connection options: copper cable, prong busbar, fork busbar, or HX3 plug busbar
  • Wide ambient temperature operating range from -25°C to 70°C
  • Accepts multi-wired conductors 1.5-25mm² and solid-core conductors 1.5-35mm²

Technical Specifications

Specification Value
Product NameMCB DX3 6000A 3 Pole 10A Curve D
ManufacturerLegrand
Reference Number408087
EAN Code3245064080873
TypeThermal Magnetic Circuit Breaker
Number of Poles3
Rated Current10 A
Rated Voltage400 V AC
Rated Insulation Voltage500 V
Rated Impulse Withstand Voltage4 kV
Breaking Capacity (Icn) at 400V6 kA
Breaking Capacity (Icu) at 230V25 kA
Breaking Capacity (Icu) at 400V10 kA
Release CharacteristicD Curve
Tripping Threshold100A - 140A (D curve between 10 In and 14 In)
Frequency50-60 Hz
Protection Degree (IP)IP20
Ambient Temperature (Operating)-25°C to 70°C
Storage Temperature-40°C to 70°C
Multi-wired Conductor Cross-section1.5-25 mm²
Solid-core Conductor Cross-section1.5-35 mm²
Connection TypeScrewed Terminal
Mounting MethodDIN Rail
Width (Modular Spacings)3
Width53.1 mm
Height94.8 mm
Depth77.8 mm
Built-in Depth44 mm
ColourGrey
RAL Number7035
Degree of Impact StrengthIK02
Pollution Degree2
Halogen FreeYes
Flush-mounted InstallationYes
Concurrently Switching Neutral ConductorNo
Additional Equipment PossibleYes
Electric Supplying DirectionBy the top or bottom
Label Space/Information SurfaceYes
Carbon Footprint (Manufacturing Phase)2.885 kg CO2 eq.
Explosion-proofNo
Standards ComplianceIEC 60898-1, IEC/EN 60529, IEC 60947-2

Order Legrand DX3 MCB 3 Pole 10A Circuit Breaker Type D | 408087 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand DX3 MCB 3 Pole 10A Circuit Breaker Type D | 408087

    SKU: 408087

      Description

      Shop Legrand DX3 MCB 3 Pole 10A Circuit Breaker Type D | 408087 In Iraq Best Prices

      Professional 3-pole thermal magnetic circuit breaker with 10A rating, 6kA breaking capacity, and advanced D-curve protection for residential and commercial electrical installations
      The Legrand DX3 MCB 6000A 3 Pole 10A Curve D is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits with a breaking capacity of 10kA at 400V AC. This modular device features advanced protection mechanisms with a tripping threshold between 100A and 140A for short-circuit protection (D curve between 10 In and 14 In). The circuit breaker can be supplied through multiple connection methods including copper cable, prong busbar (top or bottom side), fork busbar (bottom side), or Legrand HX3 plug busbar (top side), providing flexible installation options for various electrical configurations. This MCB is equipped with comprehensive safety features including IP20 protection rating against solid bodies larger than 12.5mm (fingerproof design) according to IEC/EN 60529 standards. It accepts Legrand DX3 auxiliaries, RCD add-on modules, and various accessories, allowing for system expansion and customization. The device features two independent DIN rail clamps on top and bottom sides, enabling convenient removal while the prong busbar remains in place. It includes a label holder for clear circuit identification and ON/OFF indication printed on the handle with red and green backgrounds for easy status identification. The MCB DX3 complies with substance-restriction requirements and has been designed in an environmentally conscious process with a carbon footprint of 2.885 kg CO2 equivalent during the manufacturing phase. It operates reliably across ambient temperatures from -25°C to 70°C and accepts connectable conductor cross-sections from 1.5-25mm² for multi-wired cables and 1.5-35mm² for solid-core conductors. This professional-grade electrical protection device is rated for 400V AC, 50-60Hz operation and is suitable for residential and small commercial panel installations.

      Key Features

      • Breaking capacity of 6kA at 400V AC with 10kA rated short-circuit breaking capacity per IEC 60947-2
      • D-curve protection with tripping threshold between 100A-140A for optimal short-circuit protection
      • IP20 fingerproof design protecting against solid bodies larger than 12.5mm
      • Accepts Legrand DX3 auxiliaries, RCD add-on modules and accessories for system flexibility
      • Independent DIN rail clamps allowing convenient removal without disturbing busbar connections
      • Clear circuit identification with label holder and ON/OFF status indication on handle
      • Environmentally conscious design with halogen-free construction and low carbon footprint
      • Multiple connection options: copper cable, prong busbar, fork busbar, or HX3 plug busbar
      • Wide ambient temperature operating range from -25°C to 70°C
      • Accepts multi-wired conductors 1.5-25mm² and solid-core conductors 1.5-35mm²

      Technical Specifications

      Specification Value
      Product NameMCB DX3 6000A 3 Pole 10A Curve D
      ManufacturerLegrand
      Reference Number408087
      EAN Code3245064080873
      TypeThermal Magnetic Circuit Breaker
      Number of Poles3
      Rated Current10 A
      Rated Voltage400 V AC
      Rated Insulation Voltage500 V
      Rated Impulse Withstand Voltage4 kV
      Breaking Capacity (Icn) at 400V6 kA
      Breaking Capacity (Icu) at 230V25 kA
      Breaking Capacity (Icu) at 400V10 kA
      Release CharacteristicD Curve
      Tripping Threshold100A - 140A (D curve between 10 In and 14 In)
      Frequency50-60 Hz
      Protection Degree (IP)IP20
      Ambient Temperature (Operating)-25°C to 70°C
      Storage Temperature-40°C to 70°C
      Multi-wired Conductor Cross-section1.5-25 mm²
      Solid-core Conductor Cross-section1.5-35 mm²
      Connection TypeScrewed Terminal
      Mounting MethodDIN Rail
      Width (Modular Spacings)3
      Width53.1 mm
      Height94.8 mm
      Depth77.8 mm
      Built-in Depth44 mm
      ColourGrey
      RAL Number7035
      Degree of Impact StrengthIK02
      Pollution Degree2
      Halogen FreeYes
      Flush-mounted InstallationYes
      Concurrently Switching Neutral ConductorNo
      Additional Equipment PossibleYes
      Electric Supplying DirectionBy the top or bottom
      Label Space/Information SurfaceYes
      Carbon Footprint (Manufacturing Phase)2.885 kg CO2 eq.
      Explosion-proofNo
      Standards ComplianceIEC 60898-1, IEC/EN 60529, IEC 60947-2

      Order Legrand DX3 MCB 3 Pole 10A Circuit Breaker Type D | 408087 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.


      • خيارت شحن متعددة محلية ودولية

      • ماركات عالمية أصلية

      • طرق الدفع الموجودة 100% أمنه

      • دعم 24 ساعة فى اليوم

      منتجات تم مشاهدتها

      © 2026 TOOLMART

          Login

          Forgot your password?

          Don't have an account yet?
          Create account