Shop Legrand DX3 MCB 3P 32A C Curve 10kA Circuit Breaker | 409257 In Iraq Best Prices

Professional-grade 3-pole 32A circuit-breaker with 10kA breaking capacity, C-curve protection, IP20 safety rating, and advanced energy limitation for reliable overcurrent and short-circuit protection in residential and commercial installations.
The Legrand DX³ MCB is a thermal magnetic circuit-breaker designed for three-pole installations with a rated current of 32A and C-curve release characteristic. This advanced protective device offers a breaking capacity of 10kA at 400V, providing comprehensive protection for wiring installations against overloads and short-circuits. The DX³ series features IP20 finger-safe protection, ensuring safety in residential and small commercial applications. With its current limiting class 3 design, this circuit-breaker minimizes let-through energy during fault conditions, delivering superior protection performance. Built with modern engineering standards, the DX³ 32A MCB is equipped with two DIN rail clamps (top and bottom) for independent removal while the prong busbar remains in place. The device can be supplied by copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar, offering flexible installation options. Its label holder allows clear circuit identification with ON/OFF indication printed on red and green backgrounds respectively. The unit maintains a compact built-in depth of 44mm and operates reliably across a frequency range of 50-60 Hz with ambient temperature tolerance from -25°C to 70°C. This DX³ circuit-breaker complies with all relevant international standards including IEC 60898-1 and IEC 60947-2, and is environmentally conscious with halogen-free construction. It can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories for enhanced functionality. The device is suitable for flush-mounted installation and features screwed terminal connections for secure conductor attachment. Professional installation by a qualified electrician is recommended to ensure proper operation and safety compliance.

Key Features

  • Breaking capacity of 10kA at 400V according to IEC 60898-1 standard for household installations
  • C-curve release characteristic with tripping threshold between 160A and 320A (5-10 In range)
  • IP20 finger-safe protection against solid bodies larger than 12.5mm per IEC/EN 60529
  • Current limiting class 3 for maximum energy limitation during short-circuits
  • Flexible supply options: copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar
  • Independent DIN rail removal with top and bottom clamps for convenient maintenance
  • Clear circuit identification with label holder and ON/OFF indication
  • Compatible with Legrand DX3 auxiliaries, RCD add-on modules and accessories
  • Halogen-free construction with environmentally conscious design
  • Compact 44mm built-in depth with 3-modular spacing width

Technical Specifications

Specification Value
Product TypeThermal Magnetic Circuit-Breaker (MCB)
Number of Poles3 poles (3P)
Rated Current32 Amperes
Release CharacteristicC curve
Rated Voltage400V AC
Rated Insulation Voltage500V
Rated Impulse Withstand Voltage4 kV
Breaking Capacity at 230V16 kA (Icn according to EN 60898)
Breaking Capacity at 400V10 kA (Icn according to EN 60898)
Ultimate Breaking Capacity at 230V32 kA (Icu according to IEC 60947-2)
Ultimate Breaking Capacity at 400V16 kA (Icu according to IEC 60947-2)
Current Limiting ClassClass 3
Tripping Threshold160A to 320A (5-10 In for C curve)
Degree of ProtectionIP20 (Finger-safe)
Degree of Impact StrengthIK02
Operating Frequency50-60 Hz
Ambient Temperature Operating Range-25°C to +70°C
Storage Temperature Range-40°C to +70°C
Connectable Conductor Cross Section (Multi-wired)1.5-25 mm²
Connectable Conductor Cross Section (Solid-core)1.5-35 mm²
Connection TypeScrewed Terminal
Built-in Depth44 mm
Width in Modular Spacings3 modules
Width53.1 mm
Height94.8 mm
Total Depth77.8 mm
ColourGrey (RAL 7035)
Mounting MethodDIN Rail
Flush-mounted InstallationYes
Concurrently Switching Neutral ConductorNo
Pollution Degree2
Additional Equipment PossibleYes
Explosion-proofNo
Halogen FreeYes
Electric Supplying DirectionBy the top or bottom
Label Space/Information SurfaceYes
Reference Number409257
EAN Code3245064092579
Carbon Footprint (Manufacturing Phase)3.013 kg CO₂ eq.
Product SeriesDX³ (DX3)
ManufacturerLegrand

Order Legrand DX3 MCB 3P 32A C Curve 10kA Circuit Breaker | 409257 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand DX3 MCB 3P 32A C Curve 10kA Circuit Breaker | 409257

    SKU: 409257

      Description

      Shop Legrand DX3 MCB 3P 32A C Curve 10kA Circuit Breaker | 409257 In Iraq Best Prices

      Professional-grade 3-pole 32A circuit-breaker with 10kA breaking capacity, C-curve protection, IP20 safety rating, and advanced energy limitation for reliable overcurrent and short-circuit protection in residential and commercial installations.
      The Legrand DX³ MCB is a thermal magnetic circuit-breaker designed for three-pole installations with a rated current of 32A and C-curve release characteristic. This advanced protective device offers a breaking capacity of 10kA at 400V, providing comprehensive protection for wiring installations against overloads and short-circuits. The DX³ series features IP20 finger-safe protection, ensuring safety in residential and small commercial applications. With its current limiting class 3 design, this circuit-breaker minimizes let-through energy during fault conditions, delivering superior protection performance. Built with modern engineering standards, the DX³ 32A MCB is equipped with two DIN rail clamps (top and bottom) for independent removal while the prong busbar remains in place. The device can be supplied by copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar, offering flexible installation options. Its label holder allows clear circuit identification with ON/OFF indication printed on red and green backgrounds respectively. The unit maintains a compact built-in depth of 44mm and operates reliably across a frequency range of 50-60 Hz with ambient temperature tolerance from -25°C to 70°C. This DX³ circuit-breaker complies with all relevant international standards including IEC 60898-1 and IEC 60947-2, and is environmentally conscious with halogen-free construction. It can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories for enhanced functionality. The device is suitable for flush-mounted installation and features screwed terminal connections for secure conductor attachment. Professional installation by a qualified electrician is recommended to ensure proper operation and safety compliance.

      Key Features

      • Breaking capacity of 10kA at 400V according to IEC 60898-1 standard for household installations
      • C-curve release characteristic with tripping threshold between 160A and 320A (5-10 In range)
      • IP20 finger-safe protection against solid bodies larger than 12.5mm per IEC/EN 60529
      • Current limiting class 3 for maximum energy limitation during short-circuits
      • Flexible supply options: copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar
      • Independent DIN rail removal with top and bottom clamps for convenient maintenance
      • Clear circuit identification with label holder and ON/OFF indication
      • Compatible with Legrand DX3 auxiliaries, RCD add-on modules and accessories
      • Halogen-free construction with environmentally conscious design
      • Compact 44mm built-in depth with 3-modular spacing width

      Technical Specifications

      Specification Value
      Product TypeThermal Magnetic Circuit-Breaker (MCB)
      Number of Poles3 poles (3P)
      Rated Current32 Amperes
      Release CharacteristicC curve
      Rated Voltage400V AC
      Rated Insulation Voltage500V
      Rated Impulse Withstand Voltage4 kV
      Breaking Capacity at 230V16 kA (Icn according to EN 60898)
      Breaking Capacity at 400V10 kA (Icn according to EN 60898)
      Ultimate Breaking Capacity at 230V32 kA (Icu according to IEC 60947-2)
      Ultimate Breaking Capacity at 400V16 kA (Icu according to IEC 60947-2)
      Current Limiting ClassClass 3
      Tripping Threshold160A to 320A (5-10 In for C curve)
      Degree of ProtectionIP20 (Finger-safe)
      Degree of Impact StrengthIK02
      Operating Frequency50-60 Hz
      Ambient Temperature Operating Range-25°C to +70°C
      Storage Temperature Range-40°C to +70°C
      Connectable Conductor Cross Section (Multi-wired)1.5-25 mm²
      Connectable Conductor Cross Section (Solid-core)1.5-35 mm²
      Connection TypeScrewed Terminal
      Built-in Depth44 mm
      Width in Modular Spacings3 modules
      Width53.1 mm
      Height94.8 mm
      Total Depth77.8 mm
      ColourGrey (RAL 7035)
      Mounting MethodDIN Rail
      Flush-mounted InstallationYes
      Concurrently Switching Neutral ConductorNo
      Pollution Degree2
      Additional Equipment PossibleYes
      Explosion-proofNo
      Halogen FreeYes
      Electric Supplying DirectionBy the top or bottom
      Label Space/Information SurfaceYes
      Reference Number409257
      EAN Code3245064092579
      Carbon Footprint (Manufacturing Phase)3.013 kg CO₂ eq.
      Product SeriesDX³ (DX3)
      ManufacturerLegrand

      Order Legrand DX3 MCB 3P 32A C Curve 10kA Circuit Breaker | 409257 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.


      • خيارت شحن متعددة محلية ودولية

      • ماركات عالمية أصلية

      • طرق الدفع الموجودة 100% أمنه

      • دعم 24 ساعة فى اليوم

      منتجات تم مشاهدتها

      © 2026 TOOLMART

          Login

          Forgot your password?

          Don't have an account yet?
          Create account