Description

Shop Legrand DX3 MCB 3 Pole 40A Curve B 10kA Circuit Breaker | 408995 In Iraq Best Prices

Thermal magnetic 3-pole circuit-breaker with 40A rated current, B-curve tripping, 10kA breaking capacity at 400V, IP20 protection, and DIN rail mounting for residential and small commercial installations.
The Legrand DX3 MCB is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. This 3-pole model with 40A rated current features a B-curve tripping characteristic and 10kA breaking capacity at 400V~. The device provides IP20 finger-safe protection, ensuring safety in residential and small commercial applications. It can be supplied by copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar from either the top or bottom connection point. This circuit-breaker is equipped with two DIN rail clamps allowing independent removal while the busbar remains in place. It features a label holder for clear circuit identification and on/off indication printed on the handle with red and green backgrounds for easy status recognition. The device complies with IEC 60898-1 standard with maximum energy limitation class 3, protecting against solid bodies larger than 12.5mm. It can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories for enhanced functionality. The product is halogen-free and designed in an environmentally conscious process, meeting substance-restriction requirements. With a rated insulation voltage of 500V and impulse withstand voltage of 4kV, this MCB is suitable for both flush-mounted and surface installations in diverse electrical environments. Its compact design with 3-module width and grey RAL 7035 finish makes it ideal for modern electrical panels.

Key Features

  • 10kA breaking capacity at 400V~ complying with IEC 60898-1 standard for household installations
  • B-curve tripping characteristic with short-circuit threshold between 120A and 200A (3-5 In)
  • IP20 finger-safe protection against solid bodies larger than 12.5mm per IEC/EN 60529
  • Dual DIN rail clamps for independent removal without disturbing busbar supply
  • Maximum energy limitation class 3 with label holder and clear on/off status indication
  • Compatible with copper cable, prong busbar, fork busbar, and Legrand HX3 plug busbar
  • Halogen-free and environmentally conscious design meeting substance-restriction requirements
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and accessories

Technical Specifications

Specification Value
Product TypeThermal Magnetic Circuit-Breaker
Number of Poles3 poles
Rated Current40 A
Release CharacteristicB curve
Rated Voltage400 V AC
Rated Insulation Voltage500 V
Rated Impulse Withstand Voltage4 kV
Breaking Capacity at 400V10 kA (Icn according to EN 60898)
Breaking Capacity at 230V16 kA (Icn according to EN 60898)
Ultimate Breaking Capacity at 400V16 kA (Icu according to IEC 60947-2)
Ultimate Breaking Capacity at 230V32 kA (Icu according to IEC 60947-2)
Frequency Range50-60 Hz
Current Limiting Class3
Degree of ProtectionIP20
Degree of Impact StrengthIK02
Width in Modular Spacings3 modules
Width53.1 mm
Height94.8 mm
Depth77.8 mm
Built-in Depth44 mm
Connectable Conductor Cross Section (Solid)1.5-35 mm²
Connectable Conductor Cross Section (Multi-wired)1.5-25 mm²
Connection TypeScrewed terminal
Electric Supplying DirectionTop or bottom
Mounting MethodDIN rail
Flush-mounted InstallationYes
ColourGrey
RAL Number7035
Operating Temperature Range-25 to 70 °C
Storage Temperature Range-40 to 70 °C
Pollution Degree2
Halogen FreeYes
Additional Equipment PossibleYes
Concurrently Switching Neutral ConductorNo
Explosion-proofNo
Label Space/Information SurfaceYes
Reference Number408995
EAN Code3245064089951
Carbon Footprint (Manufacturing Phase)2.891 kg CO₂ eq.

Order Legrand DX3 MCB 3 Pole 40A Curve B 10kA Circuit Breaker | 408995 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand DX3 MCB 3 Pole 40A Curve B 10kA Circuit Breaker | 408995

    SKU: 408995

      Description

      Shop Legrand DX3 MCB 3 Pole 40A Curve B 10kA Circuit Breaker | 408995 In Iraq Best Prices

      Thermal magnetic 3-pole circuit-breaker with 40A rated current, B-curve tripping, 10kA breaking capacity at 400V, IP20 protection, and DIN rail mounting for residential and small commercial installations.
      The Legrand DX3 MCB is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. This 3-pole model with 40A rated current features a B-curve tripping characteristic and 10kA breaking capacity at 400V~. The device provides IP20 finger-safe protection, ensuring safety in residential and small commercial applications. It can be supplied by copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar from either the top or bottom connection point. This circuit-breaker is equipped with two DIN rail clamps allowing independent removal while the busbar remains in place. It features a label holder for clear circuit identification and on/off indication printed on the handle with red and green backgrounds for easy status recognition. The device complies with IEC 60898-1 standard with maximum energy limitation class 3, protecting against solid bodies larger than 12.5mm. It can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories for enhanced functionality. The product is halogen-free and designed in an environmentally conscious process, meeting substance-restriction requirements. With a rated insulation voltage of 500V and impulse withstand voltage of 4kV, this MCB is suitable for both flush-mounted and surface installations in diverse electrical environments. Its compact design with 3-module width and grey RAL 7035 finish makes it ideal for modern electrical panels.

      Key Features

      • 10kA breaking capacity at 400V~ complying with IEC 60898-1 standard for household installations
      • B-curve tripping characteristic with short-circuit threshold between 120A and 200A (3-5 In)
      • IP20 finger-safe protection against solid bodies larger than 12.5mm per IEC/EN 60529
      • Dual DIN rail clamps for independent removal without disturbing busbar supply
      • Maximum energy limitation class 3 with label holder and clear on/off status indication
      • Compatible with copper cable, prong busbar, fork busbar, and Legrand HX3 plug busbar
      • Halogen-free and environmentally conscious design meeting substance-restriction requirements
      • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and accessories

      Technical Specifications

      Specification Value
      Product TypeThermal Magnetic Circuit-Breaker
      Number of Poles3 poles
      Rated Current40 A
      Release CharacteristicB curve
      Rated Voltage400 V AC
      Rated Insulation Voltage500 V
      Rated Impulse Withstand Voltage4 kV
      Breaking Capacity at 400V10 kA (Icn according to EN 60898)
      Breaking Capacity at 230V16 kA (Icn according to EN 60898)
      Ultimate Breaking Capacity at 400V16 kA (Icu according to IEC 60947-2)
      Ultimate Breaking Capacity at 230V32 kA (Icu according to IEC 60947-2)
      Frequency Range50-60 Hz
      Current Limiting Class3
      Degree of ProtectionIP20
      Degree of Impact StrengthIK02
      Width in Modular Spacings3 modules
      Width53.1 mm
      Height94.8 mm
      Depth77.8 mm
      Built-in Depth44 mm
      Connectable Conductor Cross Section (Solid)1.5-35 mm²
      Connectable Conductor Cross Section (Multi-wired)1.5-25 mm²
      Connection TypeScrewed terminal
      Electric Supplying DirectionTop or bottom
      Mounting MethodDIN rail
      Flush-mounted InstallationYes
      ColourGrey
      RAL Number7035
      Operating Temperature Range-25 to 70 °C
      Storage Temperature Range-40 to 70 °C
      Pollution Degree2
      Halogen FreeYes
      Additional Equipment PossibleYes
      Concurrently Switching Neutral ConductorNo
      Explosion-proofNo
      Label Space/Information SurfaceYes
      Reference Number408995
      EAN Code3245064089951
      Carbon Footprint (Manufacturing Phase)2.891 kg CO₂ eq.