Description

Shop Legrand DX3 MCB 2P 6A D-Curve Circuit Breaker 10kA | 409447 In Iraq Best Prices

Thermal magnetic 2-pole circuit breaker with 6A rating, D-curve release, and 16kA breaking capacity at 230V. Features IP20 finger-safe protection, flexible supply options, and compatible with Legrand DX3 accessories for reliable wiring installation protection.
The Legrand DX3 MCB 2P 6A D-Curve Circuit Breaker is a thermal magnetic protection device designed to safeguard wiring installations against overloads and short-circuits. With a 2-pole configuration and 6A rated current, this circuit breaker features a D-curve release characteristic suitable for installations with moderate inrush currents. The device offers a breaking capacity of 16kA at 230V and 10kA at 400V according to IEC 60898 standards, ensuring reliable protection for residential and small commercial applications. This MCB is equipped with advanced safety features including IP20 finger-safe protection against solid bodies larger than 12.5mm, providing enhanced installation safety. The device can be supplied via copper cable, prong busbar (top or bottom side), fork busbar (bottom side), or Legrand HX3 plug busbar (top side), offering flexible installation options. It includes a label holder for clear circuit identification and on/off indication printed on the handle with red and green backgrounds for easy status identification. The DX3 MCB is compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories, making it a versatile solution for modern electrical installations. Built with halogen-free materials and designed following environmentally conscious processes, this circuit breaker meets all substance-restriction requirements. The product operates reliably across a wide temperature range from -25°C to +70°C and features a modular design with DIN rail mounting for convenient installation and removal.

Key Features

  • Thermal magnetic protection against overloads and short-circuits with D-curve release characteristic
  • IP20 finger-safe protection against solid bodies larger than 12.5mm for enhanced installation safety
  • Breaking capacity of 16kA at 230V and 10kA at 400V according to IEC 60898 standards
  • Compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories
  • Flexible supply options via copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar
  • Label holder for clear circuit identification with on/off indication on handle
  • Halogen-free materials designed with environmentally conscious manufacturing processes
  • Wide operating temperature range from -25°C to +70°C for reliable performance
  • Modular DIN rail mounting design for convenient installation and independent removal
  • Screwed terminal connection type supporting multi-wired and solid-core conductors

Technical Specifications

Specification Value
Product TypeThermal Magnetic Circuit Breaker
Number of Poles2
Rated Current6A
Release CharacteristicD-Curve
Breaking Capacity at 230V16kA (Icn according to EN 60898)
Breaking Capacity at 400V10kA (Icn according to EN 60898)
Rated Voltage400V AC
Rated Insulation Voltage500V
Rated Impulse Withstand Voltage4kV
Frequency50-60Hz
Degree of ProtectionIP20
Degree of Impact StrengthIK02
Pollution Degree2
Connection TypeScrewed Terminal
Connectable Conductor Cross Section (Multi-wired)1.5-25mm²
Connectable Conductor Cross Section (Solid-core)1.5-35mm²
Operating Temperature Range-25°C to +70°C
Storage Temperature Range-40°C to +70°C
Width in Modular Spacings2
Width35.4mm
Height94.8mm
Depth77.8mm (Built-in depth: 44mm)
Mounting MethodDIN Rail
Supply DirectionTop or Bottom
ColourGrey (RAL 7035)
Material CompositionHalogen-free
Flush-mounted InstallationYes
Concurrently Switching Neutral ConductorNo
Additional Equipment PossibleYes
Short-circuit Breaking Capacity Icu at 230V32kA (according to IEC 60947-2)
Short-circuit Breaking Capacity Icu at 400V16kA (according to IEC 60947-2)
Carbon Footprint (Manufacturing)1.714 kg CO₂eq
Tripping Threshold (Short-circuit)60A-84A (D-curve between 10In and 14In)
Reference Number409447
EAN Code3414970434173

Order Legrand DX3 MCB 2P 6A D-Curve Circuit Breaker 10kA | 409447 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand DX3 MCB 2P 6A D-Curve Circuit Breaker 10kA | 409447

    SKU: 409447

      Description

      Shop Legrand DX3 MCB 2P 6A D-Curve Circuit Breaker 10kA | 409447 In Iraq Best Prices

      Thermal magnetic 2-pole circuit breaker with 6A rating, D-curve release, and 16kA breaking capacity at 230V. Features IP20 finger-safe protection, flexible supply options, and compatible with Legrand DX3 accessories for reliable wiring installation protection.
      The Legrand DX3 MCB 2P 6A D-Curve Circuit Breaker is a thermal magnetic protection device designed to safeguard wiring installations against overloads and short-circuits. With a 2-pole configuration and 6A rated current, this circuit breaker features a D-curve release characteristic suitable for installations with moderate inrush currents. The device offers a breaking capacity of 16kA at 230V and 10kA at 400V according to IEC 60898 standards, ensuring reliable protection for residential and small commercial applications. This MCB is equipped with advanced safety features including IP20 finger-safe protection against solid bodies larger than 12.5mm, providing enhanced installation safety. The device can be supplied via copper cable, prong busbar (top or bottom side), fork busbar (bottom side), or Legrand HX3 plug busbar (top side), offering flexible installation options. It includes a label holder for clear circuit identification and on/off indication printed on the handle with red and green backgrounds for easy status identification. The DX3 MCB is compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories, making it a versatile solution for modern electrical installations. Built with halogen-free materials and designed following environmentally conscious processes, this circuit breaker meets all substance-restriction requirements. The product operates reliably across a wide temperature range from -25°C to +70°C and features a modular design with DIN rail mounting for convenient installation and removal.

      Key Features

      • Thermal magnetic protection against overloads and short-circuits with D-curve release characteristic
      • IP20 finger-safe protection against solid bodies larger than 12.5mm for enhanced installation safety
      • Breaking capacity of 16kA at 230V and 10kA at 400V according to IEC 60898 standards
      • Compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories
      • Flexible supply options via copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar
      • Label holder for clear circuit identification with on/off indication on handle
      • Halogen-free materials designed with environmentally conscious manufacturing processes
      • Wide operating temperature range from -25°C to +70°C for reliable performance
      • Modular DIN rail mounting design for convenient installation and independent removal
      • Screwed terminal connection type supporting multi-wired and solid-core conductors

      Technical Specifications

      Specification Value
      Product TypeThermal Magnetic Circuit Breaker
      Number of Poles2
      Rated Current6A
      Release CharacteristicD-Curve
      Breaking Capacity at 230V16kA (Icn according to EN 60898)
      Breaking Capacity at 400V10kA (Icn according to EN 60898)
      Rated Voltage400V AC
      Rated Insulation Voltage500V
      Rated Impulse Withstand Voltage4kV
      Frequency50-60Hz
      Degree of ProtectionIP20
      Degree of Impact StrengthIK02
      Pollution Degree2
      Connection TypeScrewed Terminal
      Connectable Conductor Cross Section (Multi-wired)1.5-25mm²
      Connectable Conductor Cross Section (Solid-core)1.5-35mm²
      Operating Temperature Range-25°C to +70°C
      Storage Temperature Range-40°C to +70°C
      Width in Modular Spacings2
      Width35.4mm
      Height94.8mm
      Depth77.8mm (Built-in depth: 44mm)
      Mounting MethodDIN Rail
      Supply DirectionTop or Bottom
      ColourGrey (RAL 7035)
      Material CompositionHalogen-free
      Flush-mounted InstallationYes
      Concurrently Switching Neutral ConductorNo
      Additional Equipment PossibleYes
      Short-circuit Breaking Capacity Icu at 230V32kA (according to IEC 60947-2)
      Short-circuit Breaking Capacity Icu at 400V16kA (according to IEC 60947-2)
      Carbon Footprint (Manufacturing)1.714 kg CO₂eq
      Tripping Threshold (Short-circuit)60A-84A (D-curve between 10In and 14In)
      Reference Number409447
      EAN Code3414970434173

      Order Legrand DX3 MCB 2P 6A D-Curve Circuit Breaker 10kA | 409447 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.


      • خيارت شحن متعددة محلية ودولية

      • ماركات عالمية أصلية

      • طرق الدفع الموجودة 100% أمنه

      • دعم 24 ساعة فى اليوم

      منتجات تم مشاهدتها

      © 2026 TOOLMART

          Login

          Forgot your password?

          Don't have an account yet?
          Create account