Legrand DX3 2-pole 3A thermal magnetic circuit breaker with 16kA breaking capacity at 230V, Type C curve, IP20 protection, and advanced energy limitation for reliable protection of residential and small commercial electrical installations.
The Legrand DX3 MCB 2P 3A is a thermal magnetic circuit breaker designed to protect residential and small commercial wiring installations against overloads and short-circuits. With a breaking capacity of 16kA at 230V and 10kA at 400V, this device provides reliable protection with C curve tripping characteristics. The 2-pole, 3A rating makes it ideal for controlling and protecting low-current installations in homes and small commercial buildings. Featuring advanced energy limitation technology (Class 3) according to IEC 60898-1 standards, this MCB minimizes let-through energy during fault conditions, ensuring enhanced safety and equipment protection.
This circuit breaker can be supplied via multiple connection methods including copper cables, prong busbars (top or bottom side), fork busbars (bottom side), or Legrand HX3 plug busbars (top side). The device is protected against solid bodies larger than 12.5mm with IP20 rating according to IEC/EN 60529 standards. It features independent DIN rail clamps on both top and bottom sides, allowing removal without disturbing the main busbar supply. The label holder provides clear circuit identification, while ON/OFF indications printed on the handle with red and green backgrounds enable easy status monitoring.
The DX3 MCB is compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories for enhanced functionality. Its halogen-free construction demonstrates environmental responsibility, and it complies with all substance-restriction requirements. Built with robust design principles and engineered for durability, this circuit breaker is suitable for flush-mounted installation in standard distribution panels and complies with all relevant international safety standards for household and small commercial electrical installations.
Key Features
- Thermal magnetic protection with C curve tripping characteristics (5-10 In) for reliable overload and short-circuit protection
- Breaking capacity of 16kA at 230V and 10kA at 400V according to IEC 60898-1 standards
- Advanced energy limitation technology (Class 3) minimizing let-through energy during fault conditions
- 2-pole configuration with 3A rated current suitable for low-current residential and small commercial applications
- IP20 protection rating against solid bodies larger than 12.5mm for enhanced safety
- Multiple connection options: copper cables, prong busbars, fork busbars, and Legrand HX3 plug busbars
- Independent DIN rail clamps enabling removal without disturbing main busbar supply
- Clear circuit identification with label holder and ON/OFF status indication
- Compatible with Legrand DX3 auxiliaries and RCD add-on modules for extended functionality
- Halogen-free construction demonstrating environmental responsibility
Technical Specifications
| Specification |
Value |
| Product Type | Thermal Magnetic Circuit Breaker (MCB) |
| Number of Poles | 2 poles |
| Rated Current | 3 Amperes (A) |
| Release Characteristic | Type C (5-10 In tripping threshold) |
| Breaking Capacity at 230V | 16 kA (Icn according to EN 60898-1) |
| Breaking Capacity at 400V | 10 kA (Icn according to EN 60898-1) |
| Ultimate Breaking Capacity at 230V | 32 kA (Icu according to IEC 60947-2) |
| Ultimate Breaking Capacity at 400V | 16 kA (Icu according to IEC 60947-2) |
| Rated Voltage | 400 V AC |
| Rated Insulation Voltage | 500 V |
| Impulse Withstand Voltage | 4 kV |
| Voltage Type | AC (Alternating Current) |
| Frequency Range | 50-60 Hz |
| Energy Limitation Class | Class 3 |
| Protection Rating | IP20 (Protected against solid bodies > 12.5 mm) |
| Degree of Impact Strength | IK02 |
| Width (Modular Spacing) | 2 modules |
| Width | 35.4 mm |
| Height | 94.8 mm |
| Depth | 77.8 mm (Built-in depth: 44 mm) |
| Color | Grey (RAL 7035) |
| Connection Type | Screwed Terminal |
| Connectable Conductor Cross-Section (Solid-Core) | 1.5-35 mm² |
| Connectable Conductor Cross-Section (Multi-Wired) | 1.5-25 mm² |
| Mounting Method | DIN Rail |
| Installation Type | Flush-mounted installation |
| Supply Direction | By the top or bottom |
| Neutral Conductor Switching | No (2-pole configuration) |
| Pollution Degree | 2 |
| Operating Temperature Range | -25 to +70 °C |
| Storage Temperature Range | -40 to +70 °C |
| Halogen Free | Yes |
| Additional Equipment | Yes (Compatible with DX3 auxiliaries and RCD add-on modules) |
| Label Space | Yes (With label holder) |
| Reference Number | 409197 |
| EAN Code | 3245064091978 |
| Carbon Footprint (Manufacturing) | 1.730 kg CO₂ eq. |
Order Legrand DX3 MCB 2P 3A Circuit Breaker Type C | 409197 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.