Description

Shop Legrand DX3 MCB 2P 2A Curve C 6kA Circuit Breaker | 407793 In Iraq Best Prices

Thermal magnetic circuit-breaker for protecting wiring installations against overloads and short-circuits, featuring 2P, 2A C curve, 6kA breaking capacity, IP20 finger-safe protection, and DIN rail mounting.
The Legrand DX3 MCB is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. This 2-pole, 2A device features a C curve characteristic and 6kA breaking capacity according to IEC 60898-1 standard for household installations. The breaker offers IP20 finger-safe protection, preventing contact with solid bodies larger than 12.5mm, and features DIN rail mounting for easy installation and removal. With a tripping threshold between 10A and 20A for short-circuits (C curve between 5In and 10In), this device provides reliable protection for residential and small commercial electrical installations. The MCB DX3 6000A is equipped with advanced features including maximum energy limitation (class 3 according to IEC 60898-1 standard) and compatibility with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories. The device can be supplied by copper cable, prong busbar (top or bottom side), fork busbar (bottom side), or Legrand HX3 plug busbar (top side). It features dual DIN rail clamps allowing independent removal when the prong busbar is still in place. The label holder enables clear circuit identification with ON/OFF indication printed on red and green backgrounds. This product complies with substance-restriction requirements and has been designed in an environmentally conscious process with a carbon footprint of 1.973 kgCO2eq during the manufacturing phase. The breaker operates in ambient temperatures from -25°C to 70°C and supports conductor cross-sections from 1.5mm² to 35mm² for solid-core cables. It is halogen-free, meets IK02 impact strength rating, and carries multiple international certifications including VDE, AENOR, and CB scheme approvals.

Key Features

  • Breaking capacity of 6000A according to IEC 60898-1 standard for household installations
  • C curve characteristic with tripping threshold between 10A and 20A for short-circuits
  • IP20 finger-safe protection against solid bodies larger than 12.5mm
  • DIN rail mounting with dual clamps allowing independent removal
  • Maximum energy limitation class 3 according to IEC 60898-1 standard
  • Compatible with Legrand DX3 auxiliaries and RCD add-on modules
  • Label holder for clear circuit identification with ON/OFF indication
  • Supports multiple supply methods: copper cable, prong busbar, fork busbar, or HX3 plug busbar
  • Halogen-free design with environmentally conscious manufacturing process
  • Multiple international certifications: VDE, AENOR, and CB scheme

Technical Specifications

Specification Value
Product TypeThermal Magnetic Circuit-Breaker (MCB)
Number of Poles2 poles (2P)
Rated Current2 Amperes (A)
Release CharacteristicC curve
Breaking Capacity6 kA according to IEC 60898-1 at 400V
Rated Voltage400 V AC
Rated Insulation Voltage500 V
Impulse Withstand Voltage4 kV
Short-Circuit Breaking Capacity Icu at 230V25 kA according to IEC 60947-2
Short-Circuit Breaking Capacity Icu at 400V10 kA according to IEC 60947-2
Frequency Range50-60 Hz
Current Limiting ClassClass 3
Degree of ProtectionIP20 (Finger-safe)
Impact Strength RatingIK02
Width in Modular Spacings2 modules
Width Dimension35.4 mm
Height Dimension94.8 mm
Depth Dimension77.8 mm (Built-in depth: 44 mm)
Connectable Conductor Cross-Section (Solid-Core)1.5-35 mm²
Connectable Conductor Cross-Section (Multi-Wired)1.5-25 mm²
Operating Ambient Temperature-25°C to 70°C
Storage Temperature-40°C to 70°C
Connection TypeScrewed terminal
Mounting MethodDIN rail
Supply DirectionTop or bottom
ColorGrey (RAL 7035)
Halogen-FreeYes
Pollution Degree2
Concurrent Neutral Conductor SwitchingNo
Additional Equipment PossibleYes (RCD add-on modules, auxiliaries, accessories)
Flush-Mounted InstallationYes
Explosion-ProofNo
Carbon Footprint (Manufacturing Phase)1.973 kgCO₂eq
Label Space/Information SurfaceYes
Reference Number407793
EAN Code3245064077934

Order Legrand DX3 MCB 2P 2A Curve C 6kA Circuit Breaker | 407793 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.

Product form

Legrand DX3 MCB 2P 2A Curve C 6kA Circuit Breaker | 407793

    SKU: 407793

      Description

      Shop Legrand DX3 MCB 2P 2A Curve C 6kA Circuit Breaker | 407793 In Iraq Best Prices

      Thermal magnetic circuit-breaker for protecting wiring installations against overloads and short-circuits, featuring 2P, 2A C curve, 6kA breaking capacity, IP20 finger-safe protection, and DIN rail mounting.
      The Legrand DX3 MCB is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. This 2-pole, 2A device features a C curve characteristic and 6kA breaking capacity according to IEC 60898-1 standard for household installations. The breaker offers IP20 finger-safe protection, preventing contact with solid bodies larger than 12.5mm, and features DIN rail mounting for easy installation and removal. With a tripping threshold between 10A and 20A for short-circuits (C curve between 5In and 10In), this device provides reliable protection for residential and small commercial electrical installations. The MCB DX3 6000A is equipped with advanced features including maximum energy limitation (class 3 according to IEC 60898-1 standard) and compatibility with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories. The device can be supplied by copper cable, prong busbar (top or bottom side), fork busbar (bottom side), or Legrand HX3 plug busbar (top side). It features dual DIN rail clamps allowing independent removal when the prong busbar is still in place. The label holder enables clear circuit identification with ON/OFF indication printed on red and green backgrounds. This product complies with substance-restriction requirements and has been designed in an environmentally conscious process with a carbon footprint of 1.973 kgCO2eq during the manufacturing phase. The breaker operates in ambient temperatures from -25°C to 70°C and supports conductor cross-sections from 1.5mm² to 35mm² for solid-core cables. It is halogen-free, meets IK02 impact strength rating, and carries multiple international certifications including VDE, AENOR, and CB scheme approvals.

      Key Features

      • Breaking capacity of 6000A according to IEC 60898-1 standard for household installations
      • C curve characteristic with tripping threshold between 10A and 20A for short-circuits
      • IP20 finger-safe protection against solid bodies larger than 12.5mm
      • DIN rail mounting with dual clamps allowing independent removal
      • Maximum energy limitation class 3 according to IEC 60898-1 standard
      • Compatible with Legrand DX3 auxiliaries and RCD add-on modules
      • Label holder for clear circuit identification with ON/OFF indication
      • Supports multiple supply methods: copper cable, prong busbar, fork busbar, or HX3 plug busbar
      • Halogen-free design with environmentally conscious manufacturing process
      • Multiple international certifications: VDE, AENOR, and CB scheme

      Technical Specifications

      Specification Value
      Product TypeThermal Magnetic Circuit-Breaker (MCB)
      Number of Poles2 poles (2P)
      Rated Current2 Amperes (A)
      Release CharacteristicC curve
      Breaking Capacity6 kA according to IEC 60898-1 at 400V
      Rated Voltage400 V AC
      Rated Insulation Voltage500 V
      Impulse Withstand Voltage4 kV
      Short-Circuit Breaking Capacity Icu at 230V25 kA according to IEC 60947-2
      Short-Circuit Breaking Capacity Icu at 400V10 kA according to IEC 60947-2
      Frequency Range50-60 Hz
      Current Limiting ClassClass 3
      Degree of ProtectionIP20 (Finger-safe)
      Impact Strength RatingIK02
      Width in Modular Spacings2 modules
      Width Dimension35.4 mm
      Height Dimension94.8 mm
      Depth Dimension77.8 mm (Built-in depth: 44 mm)
      Connectable Conductor Cross-Section (Solid-Core)1.5-35 mm²
      Connectable Conductor Cross-Section (Multi-Wired)1.5-25 mm²
      Operating Ambient Temperature-25°C to 70°C
      Storage Temperature-40°C to 70°C
      Connection TypeScrewed terminal
      Mounting MethodDIN rail
      Supply DirectionTop or bottom
      ColorGrey (RAL 7035)
      Halogen-FreeYes
      Pollution Degree2
      Concurrent Neutral Conductor SwitchingNo
      Additional Equipment PossibleYes (RCD add-on modules, auxiliaries, accessories)
      Flush-Mounted InstallationYes
      Explosion-ProofNo
      Carbon Footprint (Manufacturing Phase)1.973 kgCO₂eq
      Label Space/Information SurfaceYes
      Reference Number407793
      EAN Code3245064077934

      Order Legrand DX3 MCB 2P 2A Curve C 6kA Circuit Breaker | 407793 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.


      • خيارت شحن متعددة محلية ودولية

      • ماركات عالمية أصلية

      • طرق الدفع الموجودة 100% أمنه

      • دعم 24 ساعة فى اليوم

      منتجات تم مشاهدتها

      © 2026 TOOLMART

          Login

          Forgot your password?

          Don't have an account yet?
          Create account