Thermal magnetic 2-pole circuit breaker with 1A B-curve rating, 16kA breaking capacity, IP20 protection, and energy limitation class 3 for residential and commercial wiring protection
The Legrand DX3 MCB 2P 1A Curve B is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. With a 1A B-curve rating and 16kA breaking capacity at 230V, this 2-pole device provides reliable protection for residential and small commercial applications. The circuit breaker features IP20 finger-safe protection and energy limitation class 3, ensuring maximum safety compliance. It can be supplied via copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar, offering flexible installation options.
This MCB is equipped with two DIN rail clamps allowing independent removal while the prong busbar remains in place. The device includes a label holder for clear circuit identification and ON/OFF indication printed on the handle with red and green backgrounds for easy status identification. Built to comply with IEC 60898-1 standard for household installations, it features a tripping threshold between 3A and 5A for short-circuit protection. The unit is halogen-free and designed with environmental consciousness in mind.
The DX3 series is compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories, making it highly versatile for different installation requirements. With a rated voltage of 400V and impulse withstand voltage of 4kV, this circuit breaker meets stringent international safety standards. The compact design with 35.4mm width and modular spacing of 2 makes it ideal for space-constrained electrical panels.
Key Features
- 16kA breaking capacity at 230V with 10kA at 400V for reliable short-circuit protection
- B-curve release characteristic with tripping threshold between 3A and 5A per IEC 60898-1
- IP20 finger-safe protection with energy limitation class 3 for maximum safety
- DIN rail mounted with independent removal capability using dual clamps
- Compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories
- Label holder and ON/OFF indication for easy circuit identification and status monitoring
- Halogen-free design with environmentally conscious manufacturing process
- Flexible supply options including copper cable, prong busbar, fork busbar, or HX3 plug busbar
Technical Specifications
| Specification |
Value |
| Product Type | Thermal Magnetic Circuit Breaker (MCB) |
| Number of Poles | 2 poles |
| Rated Current | 1 Ampere (A) |
| Release Characteristic | B-curve (3-5 In tripping threshold) |
| Rated Voltage | 400V AC |
| Rated Insulation Voltage | 500V |
| Rated Impulse Withstand Voltage | 4 kV |
| Breaking Capacity at 230V | 16 kA (Icn) / 32 kA (Icu) |
| Breaking Capacity at 400V | 10 kA (Icn) / 16 kA (Icu) |
| Frequency | 50-60 Hz |
| Current Limiting Class | Class 3 |
| Degree of Protection | IP20 (finger-safe) |
| Degree of Impact Strength | IK02 |
| Width in Modular Spacings | 2 modules |
| Physical Width | 35.4 mm |
| Physical Height | 94.8 mm |
| Physical Depth | 77.8 mm (44 mm built-in depth) |
| Connectable Conductor Cross Section (Multi-wired) | 1.5-25 mm² |
| Connectable Conductor Cross Section (Solid-core) | 1.5-35 mm² |
| Connection Type | Screwed terminal |
| Supply Direction | By top or bottom |
| Mounting Method | DIN rail |
| Colour | Grey (RAL 7035) |
| Ambient Operating Temperature | -25 to +70 °C |
| Storage Temperature | -40 to +70 °C |
| Pollution Degree | 2 |
| Halogen Free | Yes |
| Flush-mounted Installation | Yes |
| Concurrently Switching Neutral Conductor | No |
| Additional Equipment Possible | Yes |
| Explosion-proof | No |
| Standard Compliance | IEC 60898-1, IEC 60947-2, IEC/EN 60529 |
| Carbon Footprint (Manufacturing Phase) | 1.752 kg CO₂eq |
| Reference Number | 408935 |
| EAN Code | 3245064089357 |