Shop Legrand DX3 MCB 2 Pole 63A B-Curve Circuit Breaker | 408948 In Iraq Best Prices
Legrand DX3 thermal magnetic 2-pole circuit-breaker with 63A B-curve rating, 10kA/16kA breaking capacity, IP20 protection, and DIN rail mounting for residential and small commercial electrical installations.
The Legrand DX3 MCB is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. With a rated current of 63A and B-curve release characteristic, this 2-pole device provides a breaking capacity of 10kA at 400V and 16kA at 230V according to IEC 60898 standard. The device features IP20 finger-safe protection, making it suitable for residential and small commercial panel applications. It can be supplied via copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar, offering flexible installation options. The circuit-breaker is equipped with DIN rail clamps for easy mounting and removal, and includes a label holder for clear circuit identification.
This MCB incorporates advanced energy limitation (class 3) to minimize let-through energy during fault conditions, ensuring maximum protection for connected equipment. The device complies with all relevant EU directives including RoHS and REACH requirements, demonstrating environmental responsibility in its design and manufacturing process. It operates reliably across a wide temperature range (-25°C to +70°C) and is compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories for enhanced functionality.
The B-curve characteristic provides a tripping threshold between 189A and 315A (3-5 times the rated current), making it ideal for circuits with normal inrush currents typical in residential applications. With a depth of only 44mm and occupying 2 modular spacings, this compact design allows for efficient panel space utilization. The device features clear ON/OFF indication printed on the handle with red and green backgrounds for easy status identification.
Key Features
- Thermal magnetic protection with B-curve release characteristic for standard inrush current applications
- Breaking capacity of 10kA at 400V and 16kA at 230V according to IEC 60898-1 standard
- IP20 finger-safe protection with 12.5mm solid body exclusion rating
- Energy limitation class 3 for maximum fault current limitation and equipment protection
- DIN rail mounted with independent removal capability when busbar remains in place
- Compatible with Legrand DX3 auxiliaries, RCD add-on modules and various accessories
- Clear ON/OFF indication on handle with color-coded red and green backgrounds
- Label holder for convenient circuit identification and documentation
- Flexible supply options: copper cable, prong busbar, fork busbar, or HX3 plug busbar
- Environmentally conscious design compliant with RoHS and REACH directives
Technical Specifications
| Specification |
Value |
| Product Type | Thermal Magnetic Circuit-Breaker (MCB) |
| Brand | Legrand |
| Series | DX3 |
| Reference Number | 408948 |
| EAN Code | 3245064089487 |
| Number of Poles | 2 |
| Rated Current | 63 A |
| Release Characteristic | B-Curve |
| Tripping Threshold | 189-315 A (3-5 × In) |
| Rated Voltage | 400 V |
| Rated Insulation Voltage | 500 V |
| Rated Impulse Withstand Voltage | 4 kV |
| Breaking Capacity at 230V | 16 kA (Icn), 32 kA (Icu) |
| Breaking Capacity at 400V | 10 kA (Icn), 16 kA (Icu) |
| Energy Limitation Class | Class 3 |
| Degree of Protection | IP20 |
| Impact Strength | IK02 |
| Width in Modular Spacings | 2 |
| Width | 35.4 mm |
| Height | 94.8 mm |
| Depth | 77.8 mm (built-in depth 44 mm) |
| Connection Type | Screwed Terminal |
| Connectable Conductor Cross-Section (Solid) | 1.5-35 mm² |
| Connectable Conductor Cross-Section (Multi-wired) | 1.5-25 mm² |
| Mounting Method | DIN Rail |
| Supply Direction | Top or Bottom |
| Operating Temperature Range | -25°C to +70°C |
| Storage Temperature Range | -40°C to +70°C |
| Frequency | 50-60 Hz |
| Voltage Type | AC |
| Pollution Degree | 2 |
| Color | Grey |
| RAL Number | 7035 |
| Halogen Free | Yes |
| Concurrent Neutral Switching | No |
| Additional Equipment Possible | Yes |
| Carbon Footprint (Manufacturing) | 1.924 kg CO₂ eq. |
| Compliance Standards | IEC 60898-1, IEC 60947-2, EN 60529, RoHS, REACH |
Order Legrand DX3 MCB 2 Pole 63A B-Curve Circuit Breaker | 408948 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.