Shop Legrand 5kVA Single-Phase Isolating Transformer Hospital IP00 | 42593 In Iraq Best Prices
Premium 5kVA single-phase isolating transformer designed for hospital applications with dual temperature monitoring, electrostatic shield protection, and full compliance with IEC EN 61558-2-15 medical standards.
This Legrand isolating transformer is specifically designed for hospital applications, meeting the stringent requirements of IEC EN 61558-2-15 standard. The transformer features a robust construction with primary and secondary voltages of 230V, delivering a rated apparent power of 5 kVA. It is equipped with an advanced dual temperature monitoring system utilizing both bi-metal strips and thermocouple PT100 sensors, ensuring compatibility with medical control systems and enhanced safety in critical healthcare environments.
The transformer incorporates an electrostatic shield connected to a dedicated terminal, providing superior electromagnetic interference protection essential for hospital settings. Secondary/earth leakage current is strictly limited to 0.5 mA off-load, and inrush current is constrained to 12 times the peak value of primary current, ensuring patient safety and equipment protection. The IP00 degree of protection rating indicates an open design suitable for indoor installation in controlled environments.
Flexible cable terminals with 35 mm² cross-section on both primary and secondary sides facilitate easy installation and maintenance. The transformer's dimensions of 240mm width, 390mm height, and 250mm depth make it suitable for wall or cabinet mounting. Built with Type H insulation material, this isolating transformer represents a premium solution for hospital power distribution systems requiring maximum reliability and safety compliance.
Key Features
- Dual temperature monitoring system with bi-metal strips and PT100 thermocouple sensors for medical system compatibility
- Electrostatic shield connected to dedicated terminal for superior electromagnetic interference protection
- Secondary/earth leakage current limited to 0.5 mA off-load ensuring patient safety
- Inrush current limited to 12 times peak primary current for equipment protection
- Type H insulation material for enhanced thermal performance and reliability
- Flexible 35mm² cable terminals on both primary and secondary sides for easy installation
- IP00 degree of protection suitable for controlled indoor hospital environments
- Fully compliant with IEC EN 61558-2-15 standard for hospital isolating transformers
Technical Specifications
| Specification |
Value |
| Product Type | Single-Phase Isolating Transformer |
| Primary Voltage | 230V AC |
| Secondary Voltage | 230V AC with Centre Tap |
| Rated Apparent Power | 5 kVA (5000 VA) |
| Insulation Type | Type H Material |
| Degree of Protection | IP00 |
| Width | 240 mm |
| Height | 390 mm |
| Depth | 250 mm |
| Primary Cable Terminal | Flexible Cable 35 mm² |
| Secondary Cable Terminal | Flexible Cable 35 mm² |
| Relative Short Circuit Voltage | 3.1% |
| Secondary/Earth Leakage Current | 0.5 mA Off-Load (Maximum) |
| Inrush Current | Limited to 12 times peak primary current |
| Safety Standard | IEC EN 61558-2-15 |
| Temperature Monitoring | Dual System: Bi-metal Strips and PT100 Thermocouple |
| Electrostatic Shield | Yes, with Dedicated Terminal |
| Short-Circuit Proof | No |
| Ring Core | No |
| PCB Mounting Suitable | No |
| Distribution Board Mounting | No |
| Reference Number | 042593 |
| EAN Code | 3414970971449 |
| Manufacturer | Legrand |
Order Legrand 5kVA Single-Phase Isolating Transformer Hospital IP00 | 42593 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.