The Fluke 922/KIT Airflow Meter/Micromanometer enhances the capabilities of HVAC technicians by providing a complete set of tools for accurate airflow diagnostics. This kit includes the Fluke 922 micromanometer, a 12-inch pitot tube, and other accessories to facilitate comprehensive airflow analysis. With the ability to measure differential and static pressure, air velocity, and flow readings, the Fluke 922/KIT is designed for performance, ruggedness, and ease of use. The bright backlit display ensures clear viewing in all environments, and user-defined duct shape and size inputs allow for maximum airflow accuracy. Convenient colored hoses assist in proper interpretation of pressure readings, and the device offers 99-point data storage capacity with Min/Max/Average/Hold functions for easy data analysis. Auto power-off saves battery life, making it a reliable tool for field use.

 


Product Specifications:

Feature Range Resolution Accuracy
Air Pressure ±4000 Pascals 1 Pascal ±1% + 1 Pascal
±16 in H₂O 0.001 in H₂O ±1% + 0.01 in H₂O
±400 mm H₂O 0.1 mm H₂O ±1% + 0.1 mm H₂O
±40 mbar 0.01 mbar ±1% + 0.01 mbar
±0.6 PSI 0.0001 PSI ±1% + 0.0001 PSI
Air Velocity 250 to 16,000 fpm 1 fpm ±2.5% of reading at 2000 fpm (10.00 m/s)
1 to 80 m/s 0.001 m/s ±2.5% of reading at 2000 fpm (10.00 m/s)
Air Flow (Volume) 0 to 99,999 cfm 1 cfm Accuracy is a function of velocity and duct size
0 to 99,999 m³/hr 1 m³/hr Accuracy is a function of velocity and duct size
0 to 99,999 l/s 1 l/s Accuracy is a function of velocity and duct size
Temperature 0 °C to 50 °C (32 °F to 122 °F) 0.1 °C (0.1 °F) ±1% + 2 °C (±1% + 4 °F)
General Specifications
Operating Temperature 0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature -40 °C to +60 °C (-40 °F to +140 °F)
Relative Humidity 0% to 90%, non-condensing
IP Rating IP40
Operating Altitude 2000 m
Storage Altitude 12,000 m
EMI, RFI, EMC Meets requirements for EN61326-1
Vibration MIL-PREF-28800F, Class 3
Max Pressure at Each Port 10 PSI
Data Storage Capacity 99 readings
Power Four AA batteries
Battery Life 280 hours without backlight, 60 hours with backlight
Dimensions 187 mm x 91 mm x 49 mm
Weight 0.6 kg (1.3 lb)
Product form

Fluke 922/KIT Airflow Meter/Micromanometer

The Fluke 922/KIT is a comprehensive airflow measurement solution, combining a micromanometer with a 12-inch pitot tube and essential accessories for HVAC professionals. Read more

    SKU: 2679831

      The Fluke 922/KIT is a comprehensive airflow measurement solution, combining a micromanometer with a 12-inch pitot tube and essential accessories for HVAC professionals.

      Description

      The Fluke 922/KIT Airflow Meter/Micromanometer enhances the capabilities of HVAC technicians by providing a complete set of tools for accurate airflow diagnostics. This kit includes the Fluke 922 micromanometer, a 12-inch pitot tube, and other accessories to facilitate comprehensive airflow analysis. With the ability to measure differential and static pressure, air velocity, and flow readings, the Fluke 922/KIT is designed for performance, ruggedness, and ease of use. The bright backlit display ensures clear viewing in all environments, and user-defined duct shape and size inputs allow for maximum airflow accuracy. Convenient colored hoses assist in proper interpretation of pressure readings, and the device offers 99-point data storage capacity with Min/Max/Average/Hold functions for easy data analysis. Auto power-off saves battery life, making it a reliable tool for field use.

       


      Product Specifications:

      Feature Range Resolution Accuracy
      Air Pressure ±4000 Pascals 1 Pascal ±1% + 1 Pascal
      ±16 in H₂O 0.001 in H₂O ±1% + 0.01 in H₂O
      ±400 mm H₂O 0.1 mm H₂O ±1% + 0.1 mm H₂O
      ±40 mbar 0.01 mbar ±1% + 0.01 mbar
      ±0.6 PSI 0.0001 PSI ±1% + 0.0001 PSI
      Air Velocity 250 to 16,000 fpm 1 fpm ±2.5% of reading at 2000 fpm (10.00 m/s)
      1 to 80 m/s 0.001 m/s ±2.5% of reading at 2000 fpm (10.00 m/s)
      Air Flow (Volume) 0 to 99,999 cfm 1 cfm Accuracy is a function of velocity and duct size
      0 to 99,999 m³/hr 1 m³/hr Accuracy is a function of velocity and duct size
      0 to 99,999 l/s 1 l/s Accuracy is a function of velocity and duct size
      Temperature 0 °C to 50 °C (32 °F to 122 °F) 0.1 °C (0.1 °F) ±1% + 2 °C (±1% + 4 °F)
      General Specifications
      Operating Temperature 0 °C to +50 °C (+32 °F to +122 °F)
      Storage Temperature -40 °C to +60 °C (-40 °F to +140 °F)
      Relative Humidity 0% to 90%, non-condensing
      IP Rating IP40
      Operating Altitude 2000 m
      Storage Altitude 12,000 m
      EMI, RFI, EMC Meets requirements for EN61326-1
      Vibration MIL-PREF-28800F, Class 3
      Max Pressure at Each Port 10 PSI
      Data Storage Capacity 99 readings
      Power Four AA batteries
      Battery Life 280 hours without backlight, 60 hours with backlight
      Dimensions 187 mm x 91 mm x 49 mm
      Weight 0.6 kg (1.3 lb)