Description

The Fluke 922 Airflow Meter/Micromanometer is designed to simplify the diagnosis of ventilation issues by integrating three essential tools: differential pressure, airflow, and velocity measurements. This handheld device allows HVAC technicians to:

  • Measure pressure drops across key HVAC equipment to ensure optimal performance and extend equipment life.
  • Match ventilation to occupant loads.
  • Monitor indoor vs. outdoor pressure relationships to manage the building envelope.
  • Promote indoor comfort and air quality.
  • Perform duct traversals for accurate airflow readings.

The Fluke 922 features a bright, backlit display for clear viewing in various environments, user-defined duct shape and size inputs for maximum airflow accuracy, and convenient colored hoses to help interpret pressure readings accurately. Additional functions include Min/Max/Average/Hold for easy data analysis and auto power-off to conserve battery life.


Product Specifications:

Feature Range Resolution Accuracy
Air Pressure ±4000 Pascals 1 Pascal ±1% + 1 Pascal
±16 in H₂O 0.001 in H₂O ±1% + 0.01 in H₂O
±400 mm H₂O 0.1 mm H₂O ±1% + 0.1 mm H₂O
±40 mbar 0.01 mbar ±1% + 0.01 mbar
±0.6 PSI 0.0001 PSI ±1% + 0.0001 PSI
Air Velocity 250 to 16,000 fpm 1 fpm ±2.5% of reading at 2000 fpm (10.00 m/s)
1 to 80 m/s 0.001 m/s ±2.5% of reading at 2000 fpm (10.00 m/s)
Air Flow (Volume) 0 to 99,999 cfm 1 cfm Accuracy is a function of velocity and duct size
0 to 99,999 m³/hr 1 m³/hr Accuracy is a function of velocity and duct size
0 to 99,999 l/s 1 l/s Accuracy is a function of velocity and duct size
Temperature 0 °C to 50 °C (32 °F to 122 °F) 0.1 °C (0.1 °F) ±1% + 2 °C (±1% + 4 °F)
General Specifications
Operating Temperature 0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature -40 °C to +60 °C (-40 °F to +140 °F)
Relative Humidity 0% to 90%, non-condensing
IP Rating IP40
Operating Altitude 2000 m
Storage Altitude 12,000 m
EMI, RFI, EMC Meets requirements for EN61326-1
Vibration MIL-PREF-28800F, Class 3
Max Pressure at Each Port 10 PSI
Data Storage Capacity 99 readings
Warranty 2 years
Power Four AA batteries
Battery Life 280 hours without backlight, 60 hours with backlight
Product form

Fluke 922 Airflow Meter/Micromanometer

The Fluke 922 is a rugged and easy-to-use airflow meter that combines differential pressure, airflow, and velocity measurements, ideal for HVAC professionals. Read more

    SKU: 2679822

      The Fluke 922 is a rugged and easy-to-use airflow meter that combines differential pressure, airflow, and velocity measurements, ideal for HVAC professionals.

      Description

      The Fluke 922 Airflow Meter/Micromanometer is designed to simplify the diagnosis of ventilation issues by integrating three essential tools: differential pressure, airflow, and velocity measurements. This handheld device allows HVAC technicians to:

      • Measure pressure drops across key HVAC equipment to ensure optimal performance and extend equipment life.
      • Match ventilation to occupant loads.
      • Monitor indoor vs. outdoor pressure relationships to manage the building envelope.
      • Promote indoor comfort and air quality.
      • Perform duct traversals for accurate airflow readings.

      The Fluke 922 features a bright, backlit display for clear viewing in various environments, user-defined duct shape and size inputs for maximum airflow accuracy, and convenient colored hoses to help interpret pressure readings accurately. Additional functions include Min/Max/Average/Hold for easy data analysis and auto power-off to conserve battery life.


      Product Specifications:

      Feature Range Resolution Accuracy
      Air Pressure ±4000 Pascals 1 Pascal ±1% + 1 Pascal
      ±16 in H₂O 0.001 in H₂O ±1% + 0.01 in H₂O
      ±400 mm H₂O 0.1 mm H₂O ±1% + 0.1 mm H₂O
      ±40 mbar 0.01 mbar ±1% + 0.01 mbar
      ±0.6 PSI 0.0001 PSI ±1% + 0.0001 PSI
      Air Velocity 250 to 16,000 fpm 1 fpm ±2.5% of reading at 2000 fpm (10.00 m/s)
      1 to 80 m/s 0.001 m/s ±2.5% of reading at 2000 fpm (10.00 m/s)
      Air Flow (Volume) 0 to 99,999 cfm 1 cfm Accuracy is a function of velocity and duct size
      0 to 99,999 m³/hr 1 m³/hr Accuracy is a function of velocity and duct size
      0 to 99,999 l/s 1 l/s Accuracy is a function of velocity and duct size
      Temperature 0 °C to 50 °C (32 °F to 122 °F) 0.1 °C (0.1 °F) ±1% + 2 °C (±1% + 4 °F)
      General Specifications
      Operating Temperature 0 °C to +50 °C (+32 °F to +122 °F)
      Storage Temperature -40 °C to +60 °C (-40 °F to +140 °F)
      Relative Humidity 0% to 90%, non-condensing
      IP Rating IP40
      Operating Altitude 2000 m
      Storage Altitude 12,000 m
      EMI, RFI, EMC Meets requirements for EN61326-1
      Vibration MIL-PREF-28800F, Class 3
      Max Pressure at Each Port 10 PSI
      Data Storage Capacity 99 readings
      Warranty 2 years
      Power Four AA batteries
      Battery Life 280 hours without backlight, 60 hours with backlight