| Product Code | XGB-A1-01-A-HB-R-CP |
| Size | 156 x 166 x 109mm (6.1 x 6.5 x 4.3 inches) |
| Weight | 1kg (2.2 lbs) - Aluminium alloy construction |
| Power Supply | 10-30Vdc, 3W maximum |
| Electrical Output | 4-20mA current sink or source, RS-485 Modbus RTU, HART (Optional) |
| Cable Entry | 2x M20 (stopping plug fitted to left-side entry) |
| Enclosure Material | ADC 12 aluminium alloy |
| Relay Outputs | Alarm 1, Alarm 2, Fault - SPST contacts rated 1A 30Vdc |
| Sounder Output | 24Vdc nominally, 250mA maximum load |
| Operating Temperature | -40°C to +70°C (-40°F to 158°F) |
| Humidity Range | 0 to 95% RH, non-condensing |
| Repeatability | +/- 2% FSD (Full Scale Deflection) |
| Zero Drift | +/- 2% FSD per year maximum |
| Ingress Protection | IP65 (IP66 with weatherproof cap) |
| ATEX Certification | II 2 G Ex db IIC T6 Gb, Ex tb IIIC T80ᶜ Db - TUV 16 ATEX 7908 X |
| IECEx Certification | IECEx TUR16.0035 X |
| EMC Compliance | EN50270: 2015 |
| Standards | EN60079-0:2012 + A11:2013, EN60079-1:2014, IEC60079-0:2011 Edition 6, IEC60079-1:2014 Edition 7 |
| Certified Zones | Zone 1 and Zone 2 |
| Sensor Type | Molecular Property Spectrometer (MPS) |
| Detectable Gases | Up to 15 flammable gases including Hydrogen, Methane, Butane, and others |
| Calibration Requirement | No calibration required over 5+ year life |
| Price (inc VAT) | £1,395.36 |
| Price (exc VAT) | £1,162.80 |