Description

About The Product


TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V),1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications.

Technical Data


  • [Ue] rated operational voltage : Power circuit: <= 690 V AC <= 400 Hz
  • Signaling circuit: <= 690 V AC <= 400 Hz
  • [Ie] rated operational current : 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
  • 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
  • 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
  • Control circuit type : AC at 50/60 Hz
  • [Uc] control circuit voltage : 220...230 V AC 50/60 Hz
  • Motor power kW : 3 kW at 220...230 V AC 50/60 Hz AC-3
  • 5.5 kW at 380...415 V AC 50/60 Hz AC-3
  • 5.5 kW at 440 V AC 50/60 Hz AC-3
  • 4 kW at 690 V AC 50/60 Hz AC-3
  • 3 kW at 220...230 V AC 50/60 Hz AC-3e
  • 5.5 kW at 380...415 V AC 50/60 Hz AC-3e
  • 5.5 kW at 440 V AC 50/60 Hz AC-3e
  • 4 kW at 690 V AC 50/60 Hz AC-3e
  • 3 kW at 220...230 V AC 50/60 Hz AC-4
  • 5.5 kW at 380...415 V AC 50/60 Hz AC-4
  • 5.5 kW at 440 V AC 50/60 Hz AC-4
  • 4 kW at 690 V AC 50/60 Hz AC-4
  • [Uimp] rated impulse withstand voltage : 8 kV
  • [Ith] conventional free air thermal current : 20 A (at 60 °C) for power circuit
  • 10 A (at 50 °C) for signaling circuit
  • Irms rated making capacity : 144 A AC for power circuit conforming to IEC 60947
  • 110 A AC for signalling circuit conforming to IEC 60947
  • Rated breaking capacity : 110 A at 440 V conforming to IEC 60947
  • 80 A at 500 V conforming to IEC 60947
  • 70 A at 660...690 V conforming to IEC 60947
  • Inrush power in VA : 30 VA (at 20 °C)
  • Hold-in power consumption in VA : 4.5 VA (at 20 °C)
  • Heat dissipation : 1.3 W
  • Mechanical durability : 10 Mcycles
  • Electrical durability : 1.3 Mcycles 12 A AC-3 at Ue <= 440 V
  • 1.3 Mcycles 12 A AC-3e at Ue <= 440 V
  • 0.3 Mcycles 20 A AC-1 at Ue <= 690 V
  • 0.02 Mcycles 72 A AC-4 at Ue <= 440 V
  • Height : 58 mm
  • Width : 45 mm
  • Depth : 57 mm
  • Net weight : 0.18 kg
Product form

3P CONTACTOR 12A AC3 5.5KW 1NO AUX 24VAC COIL

[Ue] rated operational voltage : Power circuit: Signaling circuit: Read more

SKU: LC1K1210M7

17,750 IQD

        [Ue] rated operational voltage : Power circuit: Signaling circuit:

        Description

        About The Product


        TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V),1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications.

        Technical Data


        • [Ue] rated operational voltage : Power circuit: <= 690 V AC <= 400 Hz
        • Signaling circuit: <= 690 V AC <= 400 Hz
        • [Ie] rated operational current : 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
        • 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
        • 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
        • Control circuit type : AC at 50/60 Hz
        • [Uc] control circuit voltage : 220...230 V AC 50/60 Hz
        • Motor power kW : 3 kW at 220...230 V AC 50/60 Hz AC-3
        • 5.5 kW at 380...415 V AC 50/60 Hz AC-3
        • 5.5 kW at 440 V AC 50/60 Hz AC-3
        • 4 kW at 690 V AC 50/60 Hz AC-3
        • 3 kW at 220...230 V AC 50/60 Hz AC-3e
        • 5.5 kW at 380...415 V AC 50/60 Hz AC-3e
        • 5.5 kW at 440 V AC 50/60 Hz AC-3e
        • 4 kW at 690 V AC 50/60 Hz AC-3e
        • 3 kW at 220...230 V AC 50/60 Hz AC-4
        • 5.5 kW at 380...415 V AC 50/60 Hz AC-4
        • 5.5 kW at 440 V AC 50/60 Hz AC-4
        • 4 kW at 690 V AC 50/60 Hz AC-4
        • [Uimp] rated impulse withstand voltage : 8 kV
        • [Ith] conventional free air thermal current : 20 A (at 60 °C) for power circuit
        • 10 A (at 50 °C) for signaling circuit
        • Irms rated making capacity : 144 A AC for power circuit conforming to IEC 60947
        • 110 A AC for signalling circuit conforming to IEC 60947
        • Rated breaking capacity : 110 A at 440 V conforming to IEC 60947
        • 80 A at 500 V conforming to IEC 60947
        • 70 A at 660...690 V conforming to IEC 60947
        • Inrush power in VA : 30 VA (at 20 °C)
        • Hold-in power consumption in VA : 4.5 VA (at 20 °C)
        • Heat dissipation : 1.3 W
        • Mechanical durability : 10 Mcycles
        • Electrical durability : 1.3 Mcycles 12 A AC-3 at Ue <= 440 V
        • 1.3 Mcycles 12 A AC-3e at Ue <= 440 V
        • 0.3 Mcycles 20 A AC-1 at Ue <= 690 V
        • 0.02 Mcycles 72 A AC-4 at Ue <= 440 V
        • Height : 58 mm
        • Width : 45 mm
        • Depth : 57 mm
        • Net weight : 0.18 kg
        • Multiple shipping options local and international

        • Original international brands

        • 100% secure payment methods

        • 24/7 support