- [Ue] rated operational voltage : Power circuit <= 690 V AC 25...400 Hz
- Power circuit <= 300 V DC
About The Product
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance.
Technical Data
- [Ue] rated operational voltage : Power circuit <= 690 V AC 25...400 Hz
- Power circuit <= 300 V DC
- [Ie] rated operational current : 50 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
- 80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- 50 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit
- [Uc] control circuit voltage : 24 V DC
- Motor power kW : 15 kW 220...230 V AC 50/60 Hz AC-3)
- 22 kW 380...400 V AC 50/60 Hz AC-3)
- 30 kW 500 V AC 50/60 Hz AC-3)
- 33 kW 660...690 V AC 50/60 Hz AC-3)
- 25 kW 415 V AC 50/60 Hz AC-3)
- 30 kW 440 V AC 50/60 Hz AC-3)
- 11 kW 400 V AC 50/60 Hz AC-4)
- 15 kW 220...230 V AC 50/60 Hz AC-3e)
- 22 kW 380...400 V AC 50/60 Hz AC-3e)
- 30 kW 500 V AC 50/60 Hz AC-3e)
- 33 kW 660...690 V AC 50/60 Hz AC-3e)
- 25 kW 415 V AC 50/60 Hz AC-3e)
- 30 kW 440 V AC 50/60 Hz AC-3e)
- Motor power hp : 3 hp 115 V at AC 50/60 Hz for 1 phase
- 7.5 hp 230/240 V at AC 50/60 Hz for 1 phase
- 15 hp 200/208 V at AC 50/60 Hz for 3 phase
- 15 hp 230/240 V at AC 50/60 Hz for 3 phase
- 40 hp 460/480 V at AC 50/60 Hz for 3 phase
- 40 hp 575/600 V at AC 50/60 Hz for 3 phase
- Pole contact composition : 3 NO
- [Ith] conventional free air thermal current : 10 A 140 °F (60 °C) signalling circuit
- 80 A 140 °F (60 °C) power circuit
- Irms rated making capacity : 140 A AC signalling circuit IEC 60947-5-1
- 250 A DC signalling circuit IEC 60947-5-1
- 900 A 440 V power circuit IEC 60947
- Rated breaking capacity : 900 A 440 V power circuit IEC 60947
- Power dissipation per pole :3.7 W AC-3
- 9.6 W AC-1
- 3.7 W AC-3e
- Pollution degree : 3
- [Uimp] rated impulse withstand voltage : 6 kV IEC 60947
- Mechanical durability : 10 Mcycles
- Electrical durability : 1.45 Mcycles 50 A AC-3 <= 440 V
- 0.5 Mcycles 80 A AC-1 <= 440 V
- 1.45 Mcycles 50 A AC-3e <= 440 V
- Control circuit voltage limits : 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC
- 0.75...1.25 Uc -40…140 °F (-40…60 °C) operational DC
- 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
- Inrush power in W : 19 W 68 °F (20 °C) Hold-in power consumption in W : 7.4 W 68 °F (20 °C)
- Operating time : 42.5...57.5 ms closing
- 16...24 ms opening
- Time constant : 34 ms
- Maximum operating rate : 3600 cyc/h 140 °F (60 °C)
- Permissible ambient air temperature around the device : -40…60 °C
- 60…70 °C with derating
- Fire resistance : 850 °C conforming to IEC 60695-2-1
- Height : 122 mm
- Width : 55 mm
- Depth : 120 mm
- Net weight : 0.93 kg