وصف

المواصفات التقنية


range of product C60
range Multi 9
product name C60
product or component type Miniature circuit-breaker
device short name C60N
device application Distribution
poles description 3P
number of protected poles 3
[In] rated current 32 A at 30 °C
network type AC
trip unit technology Thermal-magnetic
curve code C
breaking capacity
6000 A Icn at 400 V AC conforming to IEC 60898
10 kA Icu at 400...415 V AC conforming to EN/IEC 60947-2
20 kA Icu at 230...240 V AC conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC conforming to EN/IEC 60947-2
suitability for isolation
Yes conforming to IEC 60947-2
[Ue] rated operational voltage 440 V AC
400 V AC
400...415 V AC
230...240 V AC
magnetic tripping limit 5...10 x In
[Ics] rated service breaking capacity
15 kA conforming to EN/IEC 60947-2 - 230...240 V AC
4.5 kA conforming to EN/IEC 60947-2 - 440 V AC
7.5 kA conforming to EN/IEC 60947-2 - 400...415 V AC
6000 A conforming to IEC 60898 - 400 V AC
[Ui] rated insulation voltage
500 V AC conforming to EN/IEC 60947-2
contact position indicator Yes
control type Toggle
local signalling ON/OFF indication
mounting mode Clip-on
mounting support
35 mm symmetrical DIN rail
9 mm pitches 6
height 81 mm
width 54 mm
depth 73 mm
net weight 0.36 kg
mechanical durability 20000 cycles
connections - terminals
Tunnel type terminals25 mm² flexible
Tunnel type terminals35 mm² rigid
tightening torque 3.5 N.m
earth-leakage protection Separate block
شكل المنتج

جوزة ثلاثية 32 امبير | C60N 3P 32A C

رمز المنتج: 24353

33,000 IQD

        وصف

        المواصفات التقنية


        range of product C60
        range Multi 9
        product name C60
        product or component type Miniature circuit-breaker
        device short name C60N
        device application Distribution
        poles description 3P
        number of protected poles 3
        [In] rated current 32 A at 30 °C
        network type AC
        trip unit technology Thermal-magnetic
        curve code C
        breaking capacity
        6000 A Icn at 400 V AC conforming to IEC 60898
        10 kA Icu at 400...415 V AC conforming to EN/IEC 60947-2
        20 kA Icu at 230...240 V AC conforming to EN/IEC 60947-2
        6 kA Icu at 440 V AC conforming to EN/IEC 60947-2
        suitability for isolation
        Yes conforming to IEC 60947-2
        [Ue] rated operational voltage 440 V AC
        400 V AC
        400...415 V AC
        230...240 V AC
        magnetic tripping limit 5...10 x In
        [Ics] rated service breaking capacity
        15 kA conforming to EN/IEC 60947-2 - 230...240 V AC
        4.5 kA conforming to EN/IEC 60947-2 - 440 V AC
        7.5 kA conforming to EN/IEC 60947-2 - 400...415 V AC
        6000 A conforming to IEC 60898 - 400 V AC
        [Ui] rated insulation voltage
        500 V AC conforming to EN/IEC 60947-2
        contact position indicator Yes
        control type Toggle
        local signalling ON/OFF indication
        mounting mode Clip-on
        mounting support
        35 mm symmetrical DIN rail
        9 mm pitches 6
        height 81 mm
        width 54 mm
        depth 73 mm
        net weight 0.36 kg
        mechanical durability 20000 cycles
        connections - terminals
        Tunnel type terminals25 mm² flexible
        Tunnel type terminals35 mm² rigid
        tightening torque 3.5 N.m
        earth-leakage protection Separate block