{"product_id":"yaoan-yr-f200-f200g-electrostatic-dust-leakage-detector","title":"Yaoan Electrostatic Dust Leakage Detector | YR F200 F200G","description":"\u003cp data-start=\"307\" data-end=\"645\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"311\" data-end=\"370\"\u003eYaoan YR-F200 F200G Electrostatic Dust Leakage Detector\u003c\/strong\u003e is designed for continuous online monitoring of dust leakage inside industrial pipelines. Using an \u003cstrong data-start=\"470\" data-end=\"516\"\u003eelectrostatic microcharge induction method\u003c\/strong\u003e, the detector identifies dust passing through the pipeline and provides a real-time indication of dust concentration conditions.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"647\" data-end=\"1060\"\u003eThe series is available in \u003cstrong data-start=\"674\" data-end=\"732\"\u003enormal-temperature and high-temperature configurations\u003c\/strong\u003e, allowing it to be used across a wide variety of industrial dust-control and filtration systems. The normal-temperature version is designed for pipeline temperatures from \u003cstrong data-start=\"904\" data-end=\"922\"\u003e-20°C to 260°C\u003c\/strong\u003e, while the high-temperature version is suitable for pipeline temperatures from \u003cstrong data-start=\"1002\" data-end=\"1020\"\u003e-20°C to 800°C\u003c\/strong\u003e according to the supplied product data.\u003c\/p\u003e\n\u003cp data-start=\"1062\" data-end=\"1363\"\u003eDesigned for harsh industrial environments, the YR-F200\/F200G features dual-environment explosion protection, IP66 ingress protection and a durable probe structure. The high-temperature configuration incorporates a longer-life probe designed to withstand elevated temperatures and pressure conditions.\u003c\/p\u003e\n\u003cp data-start=\"1365\" data-end=\"1638\"\u003eThe detector supports a standard \u003cstrong data-start=\"1398\" data-end=\"1424\"\u003e4-20 mA current output\u003c\/strong\u003e, making it suitable for integration with PLC, DCS and other industrial monitoring systems. It can also be linked with external alarm and control equipment to trigger actions when abnormal dust leakage is detected.\u003c\/p\u003e\n\u003cp data-start=\"1640\" data-end=\"1845\"\u003eRemote cloud monitoring is also supported according to the supplied product information, allowing alarm information and monitoring data to be transmitted to connected platforms for centralized supervision.\u003c\/p\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"1847\" data-end=\"1859\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1861\" data-end=\"3069\"\u003e\n\u003cli data-section-id=\"gjqwv5\" data-start=\"1861\" data-end=\"1970\"\u003e\u003cstrong data-start=\"1863\" data-end=\"1896\"\u003eElectrostatic Dust Detection:\u003c\/strong\u003e Uses microcharge induction for continuous online dust leakage monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"3xx22f\" data-start=\"1971\" data-end=\"2081\"\u003e\u003cstrong data-start=\"1973\" data-end=\"1998\"\u003eReal-Time Monitoring:\u003c\/strong\u003e Displays dust concentration conditions after dust passes through the sensing area.\u003c\/li\u003e\n\u003cli data-section-id=\"1lb7tzg\" data-start=\"2082\" data-end=\"2190\"\u003e\u003cstrong data-start=\"2084\" data-end=\"2123\"\u003eNormal and High Temperature Models:\u003c\/strong\u003e Available for standard and high-temperature pipeline applications.\u003c\/li\u003e\n\u003cli data-section-id=\"313an9\" data-start=\"2191\" data-end=\"2300\"\u003e\u003cstrong data-start=\"2193\" data-end=\"2225\"\u003eHigh Temperature Capability:\u003c\/strong\u003e High-temperature configuration supports pipeline temperatures up to 800°C.\u003c\/li\u003e\n\u003cli data-section-id=\"1qou8g6\" data-start=\"2301\" data-end=\"2407\"\u003e\u003cstrong data-start=\"2303\" data-end=\"2333\"\u003eMultiple Measuring Ranges:\u003c\/strong\u003e Available ranges include 0-10, 0-30, 0-50, 0-100, 0-500 and 0-1000 mg\/m³.\u003c\/li\u003e\n\u003cli data-section-id=\"3px7z1\" data-start=\"2408\" data-end=\"2518\"\u003e\u003cstrong data-start=\"2410\" data-end=\"2429\"\u003e4-20 mA Output:\u003c\/strong\u003e Standard industrial analogue signal for integration with monitoring and control systems.\u003c\/li\u003e\n\u003cli data-section-id=\"1wf75qt\" data-start=\"2519\" data-end=\"2613\"\u003e\u003cstrong data-start=\"2521\" data-end=\"2552\"\u003eExplosion Protected Design:\u003c\/strong\u003e Suitable for demanding industrial dust and gas environments.\u003c\/li\u003e\n\u003cli data-section-id=\"xzo026\" data-start=\"2614\" data-end=\"2695\"\u003e\u003cstrong data-start=\"2616\" data-end=\"2636\"\u003eIP66 Protection:\u003c\/strong\u003e Provides strong resistance against dust and water ingress.\u003c\/li\u003e\n\u003cli data-section-id=\"1q1zd6c\" data-start=\"2696\" data-end=\"2773\"\u003e\u003cstrong data-start=\"2698\" data-end=\"2720\"\u003eEasy Installation:\u003c\/strong\u003e One-piece design with flexible installation options.\u003c\/li\u003e\n\u003cli data-section-id=\"17ig5jk\" data-start=\"2774\" data-end=\"2876\"\u003e\u003cstrong data-start=\"2776\" data-end=\"2796\"\u003eLow Maintenance:\u003c\/strong\u003e Designed for continuous monitoring with reduced routine servicing requirements.\u003c\/li\u003e\n\u003cli data-section-id=\"1vj25bg\" data-start=\"2877\" data-end=\"2970\"\u003e\u003cstrong data-start=\"2879\" data-end=\"2908\"\u003eCloud Monitoring Support:\u003c\/strong\u003e Can be integrated with remote monitoring and alarm platforms.\u003c\/li\u003e\n\u003cli data-section-id=\"1bd9tq5\" data-start=\"2971\" data-end=\"3069\"\u003e\u003cstrong data-start=\"2973\" data-end=\"3008\"\u003eExternal Equipment Integration:\u003c\/strong\u003e Can work with alarm controllers and other connected devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"3071\" data-end=\"3089\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3091\" data-end=\"4001\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3091\" data-end=\"3118\"\u003e\n\u003ctr data-start=\"3091\" data-end=\"3118\"\u003e\n\u003cth data-start=\"3091\" data-end=\"3107\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3107\" data-end=\"3118\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3129\" data-end=\"4001\"\u003e\n\u003ctr data-start=\"3129\" data-end=\"3146\"\u003e\n\u003ctd data-start=\"3129\" data-end=\"3137\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"3137\" data-end=\"3146\" data-col-size=\"md\"\u003eYaoan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3147\" data-end=\"3178\"\u003e\n\u003ctd data-start=\"3147\" data-end=\"3156\" data-col-size=\"sm\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-start=\"3156\" data-end=\"3178\" data-col-size=\"md\"\u003eYR-F200 \/ YR-F200G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3179\" data-end=\"3233\"\u003e\n\u003ctd data-start=\"3179\" data-end=\"3194\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"3194\" data-end=\"3233\" data-col-size=\"md\"\u003eElectrostatic Dust Leakage Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3234\" data-end=\"3272\"\u003e\n\u003ctd data-start=\"3234\" data-end=\"3253\" data-col-size=\"sm\"\u003eDetection Object\u003c\/td\u003e\n\u003ctd data-start=\"3253\" data-end=\"3272\" data-col-size=\"md\"\u003eIndustrial Dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3273\" data-end=\"3324\"\u003e\n\u003ctd data-start=\"3273\" data-end=\"3292\" data-col-size=\"sm\"\u003eDetection Method\u003c\/td\u003e\n\u003ctd data-start=\"3292\" data-end=\"3324\" data-col-size=\"md\"\u003eMicrocharge Induction Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3325\" data-end=\"3396\"\u003e\n\u003ctd data-start=\"3325\" data-end=\"3343\" data-col-size=\"sm\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd data-start=\"3343\" data-end=\"3396\" data-col-size=\"md\"\u003e0-10 \/ 0-30 \/ 0-50 \/ 0-100 \/ 0-500 \/ 0-1000 mg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3397\" data-end=\"3462\"\u003e\n\u003ctd data-start=\"3397\" data-end=\"3420\" data-col-size=\"sm\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3420\" data-end=\"3462\" data-col-size=\"md\"\u003e≤ ±20 mg\/m³ according to supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3463\" data-end=\"3517\"\u003e\n\u003ctd data-start=\"3463\" data-end=\"3499\" data-col-size=\"sm\"\u003eNormal Temperature Pipeline Range\u003c\/td\u003e\n\u003ctd data-start=\"3499\" data-end=\"3517\" data-col-size=\"md\"\u003e-20°C to 260°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3518\" data-end=\"3570\"\u003e\n\u003ctd data-start=\"3518\" data-end=\"3552\" data-col-size=\"sm\"\u003eHigh Temperature Pipeline Range\u003c\/td\u003e\n\u003ctd data-start=\"3552\" data-end=\"3570\" data-col-size=\"md\"\u003e-20°C to 800°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3571\" data-end=\"3616\"\u003e\n\u003ctd data-start=\"3571\" data-end=\"3599\" data-col-size=\"sm\"\u003eEnvironmental Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3599\" data-end=\"3616\" data-col-size=\"md\"\u003e-20°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3617\" data-end=\"3668\"\u003e\n\u003ctd data-start=\"3617\" data-end=\"3642\" data-col-size=\"sm\"\u003eEnvironmental Humidity\u003c\/td\u003e\n\u003ctd data-start=\"3642\" data-end=\"3668\" data-col-size=\"md\"\u003e≤95% RH Non Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3669\" data-end=\"3711\"\u003e\n\u003ctd data-start=\"3669\" data-end=\"3685\" data-col-size=\"sm\"\u003eOutput Signal\u003c\/td\u003e\n\u003ctd data-start=\"3685\" data-end=\"3711\" data-col-size=\"md\"\u003e4-20 mA Current Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3712\" data-end=\"3757\"\u003e\n\u003ctd data-start=\"3712\" data-end=\"3734\" data-col-size=\"sm\"\u003eInstallation Method\u003c\/td\u003e\n\u003ctd data-start=\"3734\" data-end=\"3757\" data-col-size=\"md\"\u003ePipe Insertion Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3758\" data-end=\"3787\"\u003e\n\u003ctd data-start=\"3758\" data-end=\"3779\" data-col-size=\"sm\"\u003eIngress Protection\u003c\/td\u003e\n\u003ctd data-start=\"3779\" data-end=\"3787\" data-col-size=\"md\"\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3788\" data-end=\"3833\"\u003e\n\u003ctd data-start=\"3788\" data-end=\"3811\" data-col-size=\"sm\"\u003eExplosion Proof Mark\u003c\/td\u003e\n\u003ctd data-start=\"3811\" data-end=\"3833\" data-col-size=\"md\"\u003eEx db ib IIC T6 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3834\" data-end=\"3885\"\u003e\n\u003ctd data-start=\"3834\" data-end=\"3862\" data-col-size=\"sm\"\u003eDust Explosion Proof Mark\u003c\/td\u003e\n\u003ctd data-start=\"3862\" data-end=\"3885\" data-col-size=\"md\"\u003eEx tb IIIC T80°C Db\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3886\" data-end=\"3950\"\u003e\n\u003ctd data-start=\"3886\" data-end=\"3907\" data-col-size=\"sm\"\u003eAvailable Versions\u003c\/td\u003e\n\u003ctd data-start=\"3907\" data-end=\"3950\" data-col-size=\"md\"\u003eNormal Temperature and High Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3951\" data-end=\"4001\"\u003e\n\u003ctd data-start=\"3951\" data-end=\"3969\" data-col-size=\"sm\"\u003eMonitoring Type\u003c\/td\u003e\n\u003ctd data-start=\"3969\" data-end=\"4001\" data-col-size=\"md\"\u003eContinuous Online Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-section-id=\"15mmvst\" data-start=\"4003\" data-end=\"4022\"\u003eProduct Options\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"4024\" data-end=\"4157\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"4024\" data-end=\"4057\"\u003e\n\u003ctr data-start=\"4024\" data-end=\"4057\"\u003e\n\u003cth data-start=\"4024\" data-end=\"4033\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eOption\u003c\/th\u003e\n\u003cth data-start=\"4033\" data-end=\"4057\" data-col-size=\"sm\" class=\"last:pe-10\"\u003ePipeline Temperature\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4068\" data-end=\"4157\"\u003e\n\u003ctr data-start=\"4068\" data-end=\"4113\"\u003e\n\u003ctd data-start=\"4068\" data-end=\"4095\" data-col-size=\"sm\"\u003eNormal Temperature Model\u003c\/td\u003e\n\u003ctd data-start=\"4095\" data-end=\"4113\" data-col-size=\"sm\"\u003e-20°C to 260°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4114\" data-end=\"4157\"\u003e\n\u003ctd data-start=\"4114\" data-end=\"4139\" data-col-size=\"sm\"\u003eHigh Temperature Model\u003c\/td\u003e\n\u003ctd data-start=\"4139\" data-end=\"4157\" data-col-size=\"sm\"\u003e-20°C to 800°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Yaoan","offers":[{"title":"Default Title","offer_id":45150124114120,"sku":"YR-F200 \/ YR-F200G","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/ChatGPTImageJul25_2026_07_20_25PM.png?v=1784996435","url":"https:\/\/toolmart.me\/en\/products\/yaoan-yr-f200-f200g-electrostatic-dust-leakage-detector","provider":"TOOLMART","version":"1.0","type":"link"}