{"product_id":"yaoan-ht-ds400-beta-ray-dust-monitoring-system","title":"Yaoan Beta Ray Dust Monitoring System | HT DS400","description":"\u003cp data-start=\"302\" data-end=\"816\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"306\" data-end=\"356\"\u003eYaoan HT-DS400 Beta Ray Dust Monitoring System\u003c\/strong\u003e is an advanced fixed environmental monitoring solution designed for continuous online measurement of airborne particulate matter. It uses the \u003cstrong data-start=\"499\" data-end=\"530\"\u003ebeta-ray measurement method\u003c\/strong\u003e to monitor PM2.5, PM10 and TSP with stable, accurate data collection for industrial and environmental air-quality applications. Yaoan lists the HT-DS400 specifically as a beta-ray online dust monitoring system for real-time particulate monitoring. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"818\" data-end=\"1145\"\u003eThe modular design allows the system to be configured with different monitoring parameters according to site requirements. Its automatic heating and dehumidification functions help reduce interference from environmental conditions, improving measurement stability during outdoor operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1147\" data-end=\"1516\"\u003eThe HT-DS400 supports \u003cstrong data-start=\"1169\" data-end=\"1227\"\u003eautomatic continuous monitoring and scheduled sampling\u003c\/strong\u003e, with the supplied product literature indicating sampling and recording at one-hour intervals. A sampling flow of \u003cstrong data-start=\"1342\" data-end=\"1357\"\u003e16.67 L\/min\u003c\/strong\u003e is specified by Yaoan, while the operating environment covers temperatures from -20°C to 50°C and humidity up to 99% RH. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1518\" data-end=\"1871\"\u003eFor remote data management, the system supports \u003cstrong data-start=\"1566\" data-end=\"1594\"\u003e4G wireless transmission\u003c\/strong\u003e, allowing large-scale grid deployment and centralized remote supervision. Monitoring status and readings can be viewed from computers or mobile devices, while more than \u003cstrong data-start=\"1764\" data-end=\"1782\"\u003e15,000 records\u003c\/strong\u003e can be stored cyclically and exported through USB. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1873\" data-end=\"2185\"\u003eThe system can also be linked with external dust-control equipment such as tower spraying, perimeter spraying and fog cannons. When dust levels exceed preset limits, connected suppression equipment can be activated automatically to support intelligent environmental control. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"2187\" data-end=\"2199\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"2201\" data-end=\"3333\"\u003e\n\u003cli data-section-id=\"1dz2wue\" data-start=\"2201\" data-end=\"2281\"\u003e\u003cstrong data-start=\"2203\" data-end=\"2228\"\u003eBeta Ray Measurement:\u003c\/strong\u003e Provides accurate and stable particulate monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"uf3goo\" data-start=\"2282\" data-end=\"2406\"\u003e\u003cstrong data-start=\"2284\" data-end=\"2318\"\u003ePM2.5 PM10 and TSP Monitoring:\u003c\/strong\u003e Designed for continuous ambient dust measurement. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1jln6em\" data-start=\"2407\" data-end=\"2508\"\u003e\u003cstrong data-start=\"2409\" data-end=\"2435\"\u003eModular Configuration:\u003c\/strong\u003e Monitoring parameters can be selected according to project requirements.\u003c\/li\u003e\n\u003cli data-section-id=\"16jv27q\" data-start=\"2509\" data-end=\"2597\"\u003e\u003cstrong data-start=\"2511\" data-end=\"2554\"\u003eAutomatic Heating and Dehumidification:\u003c\/strong\u003e Helps reduce weather-related interference.\u003c\/li\u003e\n\u003cli data-section-id=\"1vtd4cw\" data-start=\"2598\" data-end=\"2681\"\u003e\u003cstrong data-start=\"2600\" data-end=\"2636\"\u003eContinuous Real Time Monitoring:\u003c\/strong\u003e Suitable for unattended long-term operation.\u003c\/li\u003e\n\u003cli data-section-id=\"1cxhn4q\" data-start=\"2682\" data-end=\"2750\"\u003e\u003cstrong data-start=\"2684\" data-end=\"2707\"\u003eAutomatic Sampling:\u003c\/strong\u003e Supports scheduled sampling and recording.\u003c\/li\u003e\n\u003cli data-section-id=\"8mcek\" data-start=\"2751\" data-end=\"2842\"\u003e\u003cstrong data-start=\"2753\" data-end=\"2783\"\u003e4G Wireless Communication:\u003c\/strong\u003e Suitable for remote monitoring and distributed deployment.\u003c\/li\u003e\n\u003cli data-section-id=\"15mkm08\" data-start=\"2843\" data-end=\"2950\"\u003e\u003cstrong data-start=\"2845\" data-end=\"2867\"\u003eRemote Management:\u003c\/strong\u003e Monitoring data and system status can be viewed from computers and mobile devices.\u003c\/li\u003e\n\u003cli data-section-id=\"8moj4c\" data-start=\"2951\" data-end=\"3071\"\u003e\u003cstrong data-start=\"2953\" data-end=\"2976\"\u003eLarge Data Storage:\u003c\/strong\u003e Stores more than 15,000 records for historical analysis. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1pxb5w0\" data-start=\"3072\" data-end=\"3145\"\u003e\u003cstrong data-start=\"3074\" data-end=\"3094\"\u003eUSB Data Export:\u003c\/strong\u003e Simplifies transfer and analysis of recorded data.\u003c\/li\u003e\n\u003cli data-section-id=\"1vs26s2\" data-start=\"3146\" data-end=\"3228\"\u003e\u003cstrong data-start=\"3148\" data-end=\"3175\"\u003eAutomatic Dust Control:\u003c\/strong\u003e Can be linked with fog cannons and spraying systems.\u003c\/li\u003e\n\u003cli data-section-id=\"ik8ucx\" data-start=\"3229\" data-end=\"3333\"\u003e\u003cstrong data-start=\"3231\" data-end=\"3261\"\u003eOutdoor Industrial Design:\u003c\/strong\u003e Suitable for environmental and industrial dust-monitoring applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"3335\" data-end=\"3353\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3355\" data-end=\"4151\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3355\" data-end=\"3382\"\u003e\n\u003ctr data-start=\"3355\" data-end=\"3382\"\u003e\n\u003cth data-start=\"3355\" data-end=\"3371\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3371\" data-end=\"3382\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3393\" data-end=\"4151\"\u003e\n\u003ctr data-start=\"3393\" data-end=\"3410\"\u003e\n\u003ctd data-start=\"3393\" data-end=\"3401\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"3401\" data-end=\"3410\" data-col-size=\"sm\"\u003eYaoan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3411\" data-end=\"3431\"\u003e\n\u003ctd data-start=\"3411\" data-end=\"3419\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"3419\" data-end=\"3431\" data-col-size=\"sm\"\u003eHT-DS400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3432\" data-end=\"3482\"\u003e\n\u003ctd data-start=\"3432\" data-end=\"3447\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"3447\" data-end=\"3482\" data-col-size=\"sm\"\u003eBeta Ray Dust Monitoring System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3483\" data-end=\"3525\"\u003e\n\u003ctd data-start=\"3483\" data-end=\"3507\" data-col-size=\"sm\"\u003eMonitoring Parameters\u003c\/td\u003e\n\u003ctd data-start=\"3507\" data-end=\"3525\" data-col-size=\"sm\"\u003ePM2.5 PM10 TSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3526\" data-end=\"3559\"\u003e\n\u003ctd data-start=\"3526\" data-end=\"3547\" data-col-size=\"sm\"\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd data-start=\"3547\" data-end=\"3559\" data-col-size=\"sm\"\u003eBeta Ray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3560\" data-end=\"3588\"\u003e\n\u003ctd data-start=\"3560\" data-end=\"3574\" data-col-size=\"sm\"\u003ePM2.5 Range\u003c\/td\u003e\n\u003ctd data-start=\"3574\" data-end=\"3588\" data-col-size=\"sm\"\u003e0 to 10 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3589\" data-end=\"3621\"\u003e\n\u003ctd data-start=\"3589\" data-end=\"3608\" data-col-size=\"sm\"\u003ePM2.5 Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3608\" data-end=\"3621\" data-col-size=\"sm\"\u003e0.1 μg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3622\" data-end=\"3649\"\u003e\n\u003ctd data-start=\"3622\" data-end=\"3635\" data-col-size=\"sm\"\u003ePM10 Range\u003c\/td\u003e\n\u003ctd data-start=\"3635\" data-end=\"3649\" data-col-size=\"sm\"\u003e0 to 10 mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3650\" data-end=\"3681\"\u003e\n\u003ctd data-start=\"3650\" data-end=\"3668\" data-col-size=\"sm\"\u003ePM10 Resolution\u003c\/td\u003e\n\u003ctd data-start=\"3668\" data-end=\"3681\" data-col-size=\"sm\"\u003e0.1 μg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3682\" data-end=\"3713\"\u003e\n\u003ctd data-start=\"3682\" data-end=\"3698\" data-col-size=\"sm\"\u003eSampling Flow\u003c\/td\u003e\n\u003ctd data-start=\"3698\" data-end=\"3713\" data-col-size=\"sm\"\u003e16.67 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3714\" data-end=\"3747\"\u003e\n\u003ctd data-start=\"3714\" data-end=\"3729\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3729\" data-end=\"3747\" data-col-size=\"sm\"\u003eAC 220 V 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3748\" data-end=\"3778\"\u003e\n\u003ctd data-start=\"3748\" data-end=\"3768\" data-col-size=\"sm\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-start=\"3768\" data-end=\"3778\" data-col-size=\"sm\"\u003e\u0026lt;150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3779\" data-end=\"3820\"\u003e\n\u003ctd data-start=\"3779\" data-end=\"3803\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3803\" data-end=\"3820\" data-col-size=\"sm\"\u003e-20°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3821\" data-end=\"3855\"\u003e\n\u003ctd data-start=\"3821\" data-end=\"3840\" data-col-size=\"sm\"\u003eWorking Humidity\u003c\/td\u003e\n\u003ctd data-start=\"3840\" data-end=\"3855\" data-col-size=\"sm\"\u003e0 to 99% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3856\" data-end=\"3898\"\u003e\n\u003ctd data-start=\"3856\" data-end=\"3871\" data-col-size=\"sm\"\u003eData Storage\u003c\/td\u003e\n\u003ctd data-start=\"3871\" data-end=\"3898\" data-col-size=\"sm\"\u003eMore Than 15000 Records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3899\" data-end=\"3930\"\u003e\n\u003ctd data-start=\"3899\" data-end=\"3915\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-start=\"3915\" data-end=\"3930\" data-col-size=\"sm\"\u003e4G Wireless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3931\" data-end=\"3952\"\u003e\n\u003ctd data-start=\"3931\" data-end=\"3945\" data-col-size=\"sm\"\u003eData Export\u003c\/td\u003e\n\u003ctd data-start=\"3945\" data-end=\"3952\" data-col-size=\"sm\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3953\" data-end=\"3996\"\u003e\n\u003ctd data-start=\"3953\" data-end=\"3973\" data-col-size=\"sm\"\u003eRemote Monitoring\u003c\/td\u003e\n\u003ctd data-start=\"3973\" data-end=\"3996\" data-col-size=\"sm\"\u003eComputer and Mobile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3997\" data-end=\"4056\"\u003e\n\u003ctd data-start=\"3997\" data-end=\"4017\" data-col-size=\"sm\"\u003eAutomatic Control\u003c\/td\u003e\n\u003ctd data-start=\"4017\" data-end=\"4056\" data-col-size=\"sm\"\u003eSupports Dust Suppression Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4057\" data-end=\"4093\"\u003e\n\u003ctd data-start=\"4057\" data-end=\"4070\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"4070\" data-end=\"4093\" data-col-size=\"sm\"\u003e1050 × 715 × 365 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4094\" data-end=\"4114\"\u003e\n\u003ctd data-start=\"4094\" data-end=\"4103\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"4103\" data-end=\"4114\" data-col-size=\"sm\"\u003e20.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4115\" data-end=\"4151\"\u003e\n\u003ctd data-start=\"4115\" data-end=\"4132\" data-col-size=\"sm\"\u003eCertifications\u003c\/td\u003e\n\u003ctd data-start=\"4132\" data-end=\"4151\" data-col-size=\"sm\"\u003eCE ROHS FCC SIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Yaoan","offers":[{"title":"Default Title","offer_id":45150166679752,"sku":"HT-DS400","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/ChatGPTImageJul25_2026_10_59_03PM.png?v=1785009618","url":"https:\/\/toolmart.me\/en\/products\/yaoan-ht-ds400-beta-ray-dust-monitoring-system","provider":"TOOLMART","version":"1.0","type":"link"}