{"product_id":"yaoan-gtq-ya-c100ft-six-in-one-fixed-gas-detector","title":"Yaoan Fixed Six in One Gas Detector | GTQ YA C100FT","description":"\u003cp data-start=\"306\" data-end=\"627\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"310\" data-end=\"363\"\u003eYaoan GTQ-YA-C100FT Fixed Six in One Gas Detector\u003c\/strong\u003e is designed for continuous industrial monitoring of multiple gases together with temperature and humidity. The configuration shown supports one combustible gas, three toxic gases, temperature and humidity, providing six monitoring functions in one fixed detector.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"629\" data-end=\"1011\"\u003eIts color LCD display presents gas concentration and operating information clearly, while the high-performance ARM microprocessor provides stable processing and responsive operation. Yaoan also lists fault, high and low alarm functions, infrared remote-control input, sound and light output support, and zero, calibration and testing functions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1013\" data-end=\"1339\"\u003eThe detector supports flexible communication options including \u003cstrong data-start=\"1076\" data-end=\"1121\"\u003eRS485, LoRa wireless and Two Bus PowerBus\u003c\/strong\u003e, allowing integration with industrial monitoring and control systems. Yaoan states that the unit uses LoRa communication and supports relay output for automatic equipment control. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1341\" data-end=\"1713\"\u003eDesigned for harsh industrial environments, the GTQ-YA-C100FT features \u003cstrong data-start=\"1412\" data-end=\"1431\"\u003eIP67 protection\u003c\/strong\u003e and an explosion-protected housing. It is suitable for applications such as factories, chemical and petrochemical facilities, oil and gas sites, wastewater treatment plants, warehouses and other areas requiring continuous multi-gas monitoring. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"1715\" data-end=\"1727\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1729\" data-end=\"3144\"\u003e\n\u003cli data-section-id=\"1y56cwc\" data-start=\"1729\" data-end=\"1849\"\u003e\u003cstrong data-start=\"1731\" data-end=\"1757\"\u003eSix in One Monitoring:\u003c\/strong\u003e Monitors one combustible gas, three toxic gases, temperature and humidity in a single unit.\u003c\/li\u003e\n\u003cli data-section-id=\"yw7a38\" data-start=\"1850\" data-end=\"1964\"\u003e\u003cstrong data-start=\"1852\" data-end=\"1887\"\u003eCustomisable Gas Configuration:\u003c\/strong\u003e Sensor combinations can be configured according to application requirements.\u003c\/li\u003e\n\u003cli data-section-id=\"1490c5b\" data-start=\"1965\" data-end=\"2056\"\u003e\u003cstrong data-start=\"1967\" data-end=\"1989\"\u003eColor LCD Display:\u003c\/strong\u003e Large and clear display for gas concentration and detector status.\u003c\/li\u003e\n\u003cli data-section-id=\"14yqu2f\" data-start=\"2057\" data-end=\"2185\"\u003e\u003cstrong data-start=\"2059\" data-end=\"2082\"\u003eARM Microprocessor:\u003c\/strong\u003e High-performance processing for stable and responsive operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"18ib2hx\" data-start=\"2186\" data-end=\"2328\"\u003e\u003cstrong data-start=\"2188\" data-end=\"2220\"\u003eLoRa Wireless Communication:\u003c\/strong\u003e Supports long-range wireless communication for industrial monitoring. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"rvoo48\" data-start=\"2329\" data-end=\"2458\"\u003e\u003cstrong data-start=\"2331\" data-end=\"2359\"\u003eInfrared Remote Control:\u003c\/strong\u003e Allows configuration without opening the detector enclosure. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"124ksrc\" data-start=\"2459\" data-end=\"2570\"\u003e\u003cstrong data-start=\"2461\" data-end=\"2481\"\u003eAlarm Functions:\u003c\/strong\u003e Supports fault alarm plus high and low gas alarms. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1bln3dy\" data-start=\"2571\" data-end=\"2692\"\u003e\u003cstrong data-start=\"2573\" data-end=\"2600\"\u003eSound and Light Output:\u003c\/strong\u003e Supports external audible and visual alarm functions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"4sin7x\" data-start=\"2693\" data-end=\"2802\"\u003e\u003cstrong data-start=\"2695\" data-end=\"2712\"\u003eData Storage:\u003c\/strong\u003e The supplied product information indicates storage of up to 100 records for later review.\u003c\/li\u003e\n\u003cli data-section-id=\"12rfzd2\" data-start=\"2803\" data-end=\"2922\"\u003e\u003cstrong data-start=\"2805\" data-end=\"2827\"\u003eSmart Integration:\u003c\/strong\u003e Supports RS485, LoRa and Two Bus PowerBus communication. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"19xpi50\" data-start=\"2923\" data-end=\"3059\"\u003e\u003cstrong data-start=\"2925\" data-end=\"2945\"\u003eIP67 Protection:\u003c\/strong\u003e Rugged enclosure helps protect the detector against dust and water ingress. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"ioektq\" data-start=\"3060\" data-end=\"3144\"\u003e\u003cstrong data-start=\"3062\" data-end=\"3088\"\u003eFlexible Installation:\u003c\/strong\u003e Suitable for wall-mounted or tube-mounted installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" data-start=\"3146\" data-end=\"3164\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3166\" data-end=\"4417\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3166\" data-end=\"3193\"\u003e\n\u003ctr data-start=\"3166\" data-end=\"3193\"\u003e\n\u003cth data-start=\"3166\" data-end=\"3182\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3182\" data-end=\"3193\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3204\" data-end=\"4417\"\u003e\n\u003ctr data-start=\"3204\" data-end=\"3221\"\u003e\n\u003ctd data-start=\"3204\" data-end=\"3212\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"3212\" data-end=\"3221\" data-col-size=\"md\"\u003eYaoan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3222\" data-end=\"3247\"\u003e\n\u003ctd data-start=\"3222\" data-end=\"3230\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"3230\" data-end=\"3247\" data-col-size=\"md\"\u003eGTQ-YA-C100FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3248\" data-end=\"3296\"\u003e\n\u003ctd data-start=\"3248\" data-end=\"3263\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"3263\" data-end=\"3296\" data-col-size=\"md\"\u003eFixed Six in One Gas Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3297\" data-end=\"3380\"\u003e\n\u003ctd data-start=\"3297\" data-end=\"3324\" data-col-size=\"sm\"\u003eMonitoring Configuration\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3324\" data-end=\"3380\"\u003e1 Combustible Gas 3 Toxic Gases Temperature Humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3381\" data-end=\"3457\"\u003e\n\u003ctd data-start=\"3381\" data-end=\"3400\" data-col-size=\"sm\"\u003eDetection Object\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3400\" data-end=\"3457\"\u003eCombustible Gas Toxic Gas Oxygen Temperature Humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3458\" data-end=\"3490\"\u003e\n\u003ctd data-start=\"3458\" data-end=\"3477\" data-col-size=\"sm\"\u003eDetection Method\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3477\" data-end=\"3490\"\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3491\" data-end=\"3514\"\u003e\n\u003ctd data-start=\"3491\" data-end=\"3501\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3501\" data-end=\"3514\"\u003eColor LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3515\" data-end=\"3549\"\u003e\n\u003ctd data-start=\"3515\" data-end=\"3527\" data-col-size=\"sm\"\u003eProcessor\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3527\" data-end=\"3549\"\u003eARM Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3550\" data-end=\"3579\"\u003e\n\u003ctd data-start=\"3550\" data-end=\"3568\" data-col-size=\"sm\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3568\" data-end=\"3579\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3580\" data-end=\"3633\"\u003e\n\u003ctd data-start=\"3580\" data-end=\"3616\" data-col-size=\"sm\"\u003eCombustible Gas Temperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3616\" data-end=\"3633\"\u003e-40°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3634\" data-end=\"3681\"\u003e\n\u003ctd data-start=\"3634\" data-end=\"3664\" data-col-size=\"sm\"\u003eToxic Gas Temperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3664\" data-end=\"3681\"\u003e-10°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3682\" data-end=\"3716\"\u003e\n\u003ctd data-start=\"3682\" data-end=\"3699\" data-col-size=\"sm\"\u003eHumidity Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3699\" data-end=\"3716\"\u003e15% to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3717\" data-end=\"3764\"\u003e\n\u003ctd data-start=\"3717\" data-end=\"3749\" data-col-size=\"sm\"\u003eResponse Time Combustible Gas\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3749\" data-end=\"3764\"\u003e≤30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3765\" data-end=\"3806\"\u003e\n\u003ctd data-start=\"3765\" data-end=\"3791\" data-col-size=\"sm\"\u003eResponse Time Toxic Gas\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3791\" data-end=\"3806\"\u003e≤60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3807\" data-end=\"3857\"\u003e\n\u003ctd data-start=\"3807\" data-end=\"3833\" data-col-size=\"sm\"\u003eSensor Type Combustible\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3833\" data-end=\"3857\"\u003eCatalytic Combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3858\" data-end=\"3897\"\u003e\n\u003ctd data-start=\"3858\" data-end=\"3878\" data-col-size=\"sm\"\u003eSensor Type Toxic\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3878\" data-end=\"3897\"\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3898\" data-end=\"3939\"\u003e\n\u003ctd data-start=\"3898\" data-end=\"3909\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3909\" data-end=\"3939\"\u003e±5% FS depending on sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3940\" data-end=\"3996\"\u003e\n\u003ctd data-start=\"3940\" data-end=\"3956\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3956\" data-end=\"3996\"\u003eRS485 LoRa Wireless Two Bus PowerBus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3997\" data-end=\"4025\"\u003e\n\u003ctd data-start=\"3997\" data-end=\"4017\" data-col-size=\"sm\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4017\" data-end=\"4025\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4026\" data-end=\"4053\"\u003e\n\u003ctd data-start=\"4026\" data-end=\"4035\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4035\" data-end=\"4053\"\u003eApprox. 2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4054\" data-end=\"4088\"\u003e\n\u003ctd data-start=\"4054\" data-end=\"4067\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4067\" data-end=\"4088\"\u003e207 x 214 x 84 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4089\" data-end=\"4136\"\u003e\n\u003ctd data-start=\"4089\" data-end=\"4104\" data-col-size=\"sm\"\u003eInstallation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4104\" data-end=\"4136\"\u003eWall Mounted or Tube Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4137\" data-end=\"4185\"\u003e\n\u003ctd data-start=\"4137\" data-end=\"4155\" data-col-size=\"sm\"\u003eAlarm Functions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4155\" data-end=\"4185\"\u003eFault High Alarm Low Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4186\" data-end=\"4232\"\u003e\n\u003ctd data-start=\"4186\" data-end=\"4205\" data-col-size=\"sm\"\u003eRemote Operation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4205\" data-end=\"4232\"\u003eInfrared Remote Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4233\" data-end=\"4333\"\u003e\n\u003ctd data-start=\"4233\" data-end=\"4256\" data-col-size=\"sm\"\u003eExplosion Proof Mark\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4256\" data-end=\"4333\"\u003eEx db IIC T6 Gb and Ex tb IIIC T80°C Db as shown in supplied product data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4334\" data-end=\"4417\"\u003e\n\u003ctd data-start=\"4334\" data-end=\"4351\" data-col-size=\"sm\"\u003eCertifications\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4351\" data-end=\"4374\"\u003eATEX CE FCC ROHS SIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Yaoan","offers":[{"title":"Default Title","offer_id":45150108254408,"sku":"GTQ-YA-C100FT","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/ChatGPTImageJul25_2026_05_15_41PM.png?v=1784988966","url":"https:\/\/toolmart.me\/en\/products\/yaoan-gtq-ya-c100ft-six-in-one-fixed-gas-detector","provider":"TOOLMART","version":"1.0","type":"link"}