{"product_id":"mcb-dx3-4-pole-6a-curve-d-circuit-breaker-409844","title":"Legrand MCB DX3 Four Pole 6A Curve D Circuit Breaker | 409844","description":"\u003cp\u003eShop Legrand MCB DX3 Four Pole 6A Curve D Circuit Breaker | 409844 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n High-performance four-pole modular circuit breaker with 25kA breaking capacity, D-curve protection, and IP20 rating for reliable electrical circuit protection\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The MCB DX3 Four Pole 6A Curve D is a modular thermal-magnetic circuit breaker designed for reliable protection and isolation of electrical circuits in residential and small commercial installations. This advanced protective device delivers an impressive 25kA breaking capacity at 400V AC, making it ideal for demanding electrical environments. With its D-curve protection characteristic, it provides optimal tripping thresholds between 60A and 84A for short-circuit conditions, ensuring superior circuit protection against overloads and faults.\n \n This circuit breaker features a fully visible breaking mechanism that allows users to clearly see the operational status of the device. The IP20 protection rating ensures the device is protected against solid bodies larger than 12.5mm, making it fingerproof and safe for installation in various environments. The breaker can be supplied through multiple connection methods including copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar, providing flexibility in installation configurations.\n \n The DX3 is engineered with DIN rail mounting capability, featuring two independent clamps on the top and bottom sides for easy installation and removal even when the busbar is energized. It is compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories, allowing for customization and expansion of protection systems. The device complies with all substance-restriction requirements and has been designed with environmental consciousness in mind, featuring halogen-free construction.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003e25kA breaking capacity at 400V AC for superior fault protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eD-curve thermal-magnetic protection with 60A-84A tripping threshold\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eFully visible breaking mechanism for clear operational status indication\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 fingerproof protection against solid bodies larger than 12.5mm\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDIN rail mounting with independent top and bottom clamps for flexible installation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with Legrand DX3 auxiliaries and RCD add-on modules\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eMultiple connection options: copper cable, prong busbar, fork busbar, or HX3 plug busbar\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eHalogen-free construction with environmental consciousness\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eLabel holder for clear circuit identification\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eOn\/off indication printed on handle with red and green backgrounds\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eModular Thermal-Magnetic Circuit Breaker\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e4 poles (4 protected poles)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e6 Amperes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelease Characteristic\u003c\/td\u003e\u003ctd\u003eD-curve\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity at 400V\u003c\/td\u003e\u003ctd\u003e25 kA according to IEC 60947-2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity at 230V\u003c\/td\u003e\u003ctd\u003e50 kA according to IEC 60947-2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\u003ctd\u003e500V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\u003ctd\u003e4 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNominal Voltage Range\u003c\/td\u003e\u003ctd\u003e360-440V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP20 (fingerproof, protected against solid bodies \u003e12.5mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpact Strength Rating\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth in Modular Spacings\u003c\/td\u003e\u003ctd\u003e4 spaces\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePhysical Width\u003c\/td\u003e\u003ctd\u003e70.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePhysical Height\u003c\/td\u003e\u003ctd\u003e94.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePhysical Depth\u003c\/td\u003e\u003ctd\u003e77.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBuilt-in Depth\u003c\/td\u003e\u003ctd\u003e44 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross-Section (Multi-wired)\u003c\/td\u003e\u003ctd\u003e1.5-25 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross-Section (Solid-core)\u003c\/td\u003e\u003ctd\u003e1.5-35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed terminal, Busbar, and Cable\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSupply Direction\u003c\/td\u003e\u003ctd\u003eTop or Bottom\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN Rail with independent top and bottom clamps\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-Mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNeutral Conductor Switching\u003c\/td\u003e\u003ctd\u003eConcurrently switching neutral conductor\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColour\u003c\/td\u003e\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes - compatible with DX3 auxiliaries and RCD add-on modules\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eLabel Holder\u003c\/td\u003e\u003ctd\u003eYes - for circuit identification\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eExplosion-Proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e409844\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245064098441\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCarbon Footprint (Manufacturing)\u003c\/td\u003e\u003ctd\u003e3.589 kg CO₂ eq.\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand MCB DX3 Four Pole 6A Curve D Circuit Breaker | 409844 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45172747829448,"sku":"409844","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/aeaf53d4-9304-4383-8cb9-ce71328f4ad0.webp?v=1786555104","url":"https:\/\/toolmart.me\/en\/products\/mcb-dx3-4-pole-6a-curve-d-circuit-breaker-409844","provider":"TOOLMART","version":"1.0","type":"link"}