{"product_id":"legrand-tx3-mcb-2p-2a-curve-b-10ka-circuit-breaker-404106","title":"Legrand TX3 MCB 2P 2A Curve B 10kA Circuit Breaker | 404106","description":"\u003cp\u003eShop Legrand TX3 MCB 2P 2A Curve B 10kA Circuit Breaker | 404106 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Professional-grade thermal magnetic circuit-breaker with 10kA breaking capacity, 2A rated current, B-curve protection, and IP20 finger-safe design for residential and commercial electrical installations.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand TX3 MCB is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits with exceptional reliability and safety. With a breaking capacity of 10kA according to IEC 60898-1 standard, this 2-pole device operates at 2A rated current and features a B-curve characteristic that provides optimal tripping between 3In and 5In for short-circuit protection. The device is IP20 finger-safe protected, preventing contact with solid bodies larger than 12.5mm, making it ideal for residential and small commercial panel applications.\n \n This circuit breaker offers advanced protection features including maximum energy limitation (energy limitation class 3) and can be supplied via copper cable, prong busbar, or fork busbar connections. The TX3 is equipped with a special DIN rail clamp on the bottom side, allowing independent removal even when the fork busbar is still in place. It features a convenient label holder for circuit identification and clear ON\/OFF indication on the handle with red and green backgrounds for easy status recognition.\n \n The product complies with all substance-restriction requirements and has been designed following environmentally conscious manufacturing processes. Compatible with Legrand DX3 auxiliaries and accessories, it can also be connected to aluminum cables using the appropriate Legrand terminal accessory. Installation should be performed by a qualified electrician in compliance with local installation rules to ensure optimal safety and performance.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003e10kA breaking capacity according to IEC 60898-1 standard for household installations\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eB-curve characteristic with tripping threshold between 3In and 5In for reliable short-circuit protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 finger-safe protection preventing contact with solid bodies larger than 12.5mm\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eEnergy limitation class 3 providing maximum let-through energy limitation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with Legrand DX3 auxiliaries and accessories for expanded functionality\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSpecial DIN rail clamp allowing independent removal without disturbing busbar connections\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eClear label holder and ON\/OFF indication for easy circuit identification and status recognition\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eMultiple connection options: copper cable, prong busbar, or fork busbar\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eHalogen-free design supporting environmental sustainability\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eRoHS and REACH compliant for substance-restriction requirements\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eThermal Magnetic Circuit-Breaker (MCB)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBrand\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSeries\u003c\/td\u003e\u003ctd\u003eTX3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e404106\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3414970392299\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e2 poles (2P)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eProtected Poles\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e2 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\u003ctd\u003e500 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\u003ctd\u003e4 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelease Characteristic\u003c\/td\u003e\u003ctd\u003eB curve\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit Breaking Capacity (Icn) at 230V\u003c\/td\u003e\u003ctd\u003e16 kA according to EN 60898\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit Breaking Capacity (Icn) at 400V\u003c\/td\u003e\u003ctd\u003e10 kA according to EN 60898\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCurrent Limiting Class\u003c\/td\u003e\u003ctd\u003eClass 3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eVoltage Type\u003c\/td\u003e\u003ctd\u003eAC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency Range\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNominal Voltage Range\u003c\/td\u003e\u003ctd\u003e240-415 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection (IP)\u003c\/td\u003e\u003ctd\u003eIP20\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpact Strength (IK)\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth in Modular Spacings\u003c\/td\u003e\u003ctd\u003e2 modules\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e35.4 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e88 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e77.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBuilt-in Depth\u003c\/td\u003e\u003ctd\u003e44 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColor\u003c\/td\u003e\u003ctd\u003eGrey\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRAL Number\u003c\/td\u003e\u003ctd\u003e7035\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN rail\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed terminal, Busbar and cable\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eElectric Supply Direction\u003c\/td\u003e\u003ctd\u003eTop or bottom\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-Mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConcurrently Switching Neutral\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes (Legrand DX3 auxiliaries and accessories)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eExplosion-Proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eLabel Space\/Information Surface\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCompliance Standards\u003c\/td\u003e\u003ctd\u003eIEC 60898-1, IEC\/EN 60529, RoHS, REACH\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand TX3 MCB 2P 2A Curve B 10kA Circuit Breaker | 404106 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45159425638600,"sku":"404106","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/ca575f70-0159-4887-8f51-2201fd00c3ca.webp?v=1785763617","url":"https:\/\/toolmart.me\/en\/products\/legrand-tx3-mcb-2p-2a-curve-b-10ka-circuit-breaker-404106","provider":"TOOLMART","version":"1.0","type":"link"}