{"product_id":"legrand-three-phase-isolating-transformer-hospital-8kva-400v-230v-042584","title":"Legrand Three-Phase Isolating Transformer Hospital 8kVA 400V\/230V | 42584","description":"\u003cp\u003eShop Legrand Three-Phase Isolating Transformer Hospital 8kVA 400V\/230V | 42584 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Professional three-phase isolating transformer for hospitals with 8 kVA output, 400V\/230V conversion, temperature monitoring, electrostatic shield, and full IEC 61558-2-15 compliance for maximum safety.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n This Legrand three-phase isolating transformer is specifically designed for hospital applications and complies with the stringent requirements of IEC EN 61558-2-15 standard. The transformer features a robust construction with an output capacity of 8 kVA, converting primary voltage of 400V to secondary voltage of 230V. It is equipped with advanced safety features including an electrostatic shield connected to dedicated terminals and a temperature monitoring system with bi-metal strips for connection to control systems such as optical or acoustic alarms.\n \n The transformer is built with YY wiring configuration and features IP21 degree of protection with IK08 impact strength rating. It includes flexible cable terminals with 16 mm² for primary and 35 mm² for secondary connections, ensuring secure and reliable installation. The secondary\/earth leakage current is limited to 0.5 mA off-load, and the inrush current is controlled to 12 times the peak value of primary current, meeting the highest safety standards required in hospital environments.\n \n With dimensions of 470mm width × 410mm height × 340mm depth, this transformer is designed for efficient space utilization in medical facilities. The H-class insulation material provides excellent thermal performance and durability. The terminal marking indication and screwed terminal connections ensure proper identification and secure electrical connections for professional installation and maintenance.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eThree-phase isolating transformer compliant with IEC EN 61558-2-15 hospital standard\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e8 kVA output capacity with 400V primary to 230V secondary conversion\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIntegrated electrostatic shield connected to dedicated terminals for enhanced safety\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eTemperature monitoring system with bi-metal strips and control system connectivity\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSecondary\/earth leakage current limited to 0.5 mA off-load with controlled inrush current\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP21 degree of protection with IK08 impact strength rating\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eH-class insulation material for superior thermal performance and durability\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eYY wiring configuration for optimal three-phase distribution\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eFlexible cable terminals: 16 mm² primary and 35 mm² secondary\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eScrewed terminal connections for secure and professional installation\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eThree-Phase Isolating Transformer\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eApplication\u003c\/td\u003e\u003ctd\u003eHospital Medical Facilities\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Power Output\u003c\/td\u003e\u003ctd\u003e8 kVA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\u003ctd\u003e400V ±10% (Three-phase + Neutral)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\u003ctd\u003e230V (Three-phase + Neutral)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWiring Configuration\u003c\/td\u003e\u003ctd\u003eYY (Star-Star)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInsulation Class\u003c\/td\u003e\u003ctd\u003eH (180°C)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit Voltage\u003c\/td\u003e\u003ctd\u003e2.7%\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary\/Earth Leakage Current\u003c\/td\u003e\u003ctd\u003e0.5 mA off-load maximum\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInrush Current Limitation\u003c\/td\u003e\u003ctd\u003e12 times peak primary current maximum\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection (IP)\u003c\/td\u003e\u003ctd\u003eIP21\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpact Strength Rating (IK)\u003c\/td\u003e\u003ctd\u003eIK08\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTemperature Monitoring\u003c\/td\u003e\u003ctd\u003eBi-metal strips with control system connectivity\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eElectrostatic Shield\u003c\/td\u003e\u003ctd\u003eYes, connected to dedicated terminals\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Cable Terminal\u003c\/td\u003e\u003ctd\u003eFlexible cable 16 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Cable Terminal\u003c\/td\u003e\u003ctd\u003eFlexible cable 35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed Terminals\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTerminal Marking\u003c\/td\u003e\u003ctd\u003eYes, clearly indicated\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e470 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e410 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e340 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSafety Transformer\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eIsolating Transformer\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEnergy Saving Transformer\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit Proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInternational Standard Compliance\u003c\/td\u003e\u003ctd\u003eIEC EN 61558-2-15, IEC 61558-2-4\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e042584\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245060425845\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eManufacturer\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand Three-Phase Isolating Transformer Hospital 8kVA 400V\/230V | 42584 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45140996489416,"sku":"042584","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/945cc55d-1d36-4ac1-9a44-9cdf32a0b791.webp?v=1784069109","url":"https:\/\/toolmart.me\/en\/products\/legrand-three-phase-isolating-transformer-hospital-8kva-400v-230v-042584","provider":"TOOLMART","version":"1.0","type":"link"}