{"product_id":"legrand-three-phase-isolating-transformer-hospital-6-3-kva-042583","title":"Legrand Three-Phase Isolating Transformer Hospital 6.3 kVA | 42583","description":"\u003cp\u003eShop Legrand Three-Phase Isolating Transformer Hospital 6.3 kVA | 42583 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Hospital-grade three-phase isolating transformer with 6.3 kVA output, IEC EN 61558-2-15 certified, featuring temperature monitoring system and electrostatic shield for maximum safety and reliability.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n This Legrand isolating transformer is specifically designed for hospital applications and complies with the stringent requirements of IEC EN 61558-2-15 standard. The three-phase transformer features a primary voltage of 400V and secondary voltage of 230V, with a rated output power of 6.3 kVA. It is equipped with an advanced temperature monitoring system using bi-metal strips for connection to control systems, ensuring optimal operational safety and performance in critical healthcare environments.\n \n The transformer incorporates an electrostatic shield linked to a dedicated terminal, which significantly reduces electromagnetic interference and enhances electrical safety. The secondary\/earth leakage current is limited to 0.5 mA off-load, and the inrush current is restricted to 12 times the peak value of primary current, meeting all international safety standards. With an IP21 degree of protection and IK08 impact strength rating, this transformer is built to withstand demanding hospital conditions.\n \n The unit features flexible cable terminals with 10 mm² on the primary side and 16 mm² on the secondary side, allowing for easy and secure installation. The transformer operates with a YY wiring system and has a relative short-circuit voltage of 2.8%, ensuring stable and reliable power distribution. Its compact dimensions (470mm width × 410mm height × 340mm depth) and robust construction make it an ideal choice for modern hospital electrical infrastructure.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eIEC EN 61558-2-15 compliant hospital-grade isolating transformer\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eAdvanced temperature monitoring system with bi-metal strips for automatic control\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eElectrostatic shield with dedicated terminal for enhanced electromagnetic protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSecondary\/earth leakage current limited to 0.5 mA off-load for maximum safety\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eInrush current restriction to 12 times peak primary current value\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eThree-Phase Isolating Transformer\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\u003ctd\u003e400V AC + Neutral\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\u003ctd\u003e230V AC + Neutral\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Power Output\u003c\/td\u003e\u003ctd\u003e6.3 kVA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWiring System\u003c\/td\u003e\u003ctd\u003eYY (Star-Star)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelative Short-Circuit Voltage\u003c\/td\u003e\u003ctd\u003e2.8%\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInsulation Material Class\u003c\/td\u003e\u003ctd\u003eClass H (IEC 85)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP21\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpact Strength Rating\u003c\/td\u003e\u003ctd\u003eIK08\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Terminal Cable Size\u003c\/td\u003e\u003ctd\u003e10 mm² flexible cable\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Terminal Cable Size\u003c\/td\u003e\u003ctd\u003e16 mm² flexible cable\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed terminals\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e470 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e410 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e340 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary\/Earth Leakage Current\u003c\/td\u003e\u003ctd\u003e0.5 mA off-load maximum\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInrush Current Limitation\u003c\/td\u003e\u003ctd\u003e12 times peak primary current\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTemperature Monitoring\u003c\/td\u003e\u003ctd\u003eBi-metal strips with dedicated terminals\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit-Proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSafety Standard Compliance\u003c\/td\u003e\u003ctd\u003eIEC EN 61558-2-15\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand Three-Phase Isolating Transformer Hospital 6.3 kVA | 42583 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45140996456648,"sku":"042583","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/ff9390a6-694d-45e3-8a53-c0907dccf1f9.webp?v=1784069104","url":"https:\/\/toolmart.me\/en\/products\/legrand-three-phase-isolating-transformer-hospital-6-3-kva-042583","provider":"TOOLMART","version":"1.0","type":"link"}