{"product_id":"legrand-single-phase-isolating-transformer-hospital-ip21-6-3kva-042574","title":"Legrand Single-Phase Isolating Transformer Hospital IP21 6.3kVA | 42574","description":"\u003cp\u003eShop Legrand Single-Phase Isolating Transformer Hospital IP21 6.3kVA | 42574 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Hospital-grade single-phase isolating transformer with dual temperature monitoring, IP21 protection, 6.3kVA output, and full medical safety compliance for healthcare facility installations.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n This Legrand isolating transformer is specifically designed for hospital environments and complies with IEC EN 61558-2-15 standards. It features a single-phase configuration with primary voltage of 230V and secondary voltage of 230V with centre tap, delivering a rated apparent power of 6.3 kVA. The transformer is equipped with dual temperature monitoring systems including bi-metal strips and thermocouple PT100 sensors, making it fully compatible with medical control systems. The IP21 degree of protection ensures safety in clinical settings.\n \n The transformer incorporates an electrostatic shield connected to a dedicated terminal, which is essential for medical applications requiring isolation and protection from electrical interference. It features flexible cable terminals rated at 35mm² for both primary and secondary connections, ensuring secure and reliable installations. The secondary\/earth leakage current is limited to 0.5mA off-load, and the inrush current is restricted to 12 times the peak value of primary current, meeting strict medical safety requirements.\n \n With dimensions of 340mm (W) x 410mm (H) x 370mm (D) and constructed with H-class insulation material, this transformer is built to withstand demanding hospital environments. It is non-short-circuit-proof with a relative short circuit voltage of 2.8%, and is not suitable for PCB mounting or distribution board installation. The product reference 042574 comes with comprehensive technical documentation and BIM data for integration into healthcare facility designs.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eCompliant with IEC EN 61558-2-15 hospital transformer standards\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDual temperature monitoring systems with bi-metal strips and PT100 thermocouples\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eElectrostatic shield with dedicated terminal for medical-grade isolation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP21 degree of protection for safe clinical environment operation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSecondary\/earth leakage current limited to 0.5mA off-load for patient safety\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSingle-phase 230V to 230V with centre tap configuration\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e6.3 kVA rated apparent power output capacity\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eH-class insulation material for enhanced durability\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e35mm² flexible cable terminals for secure connections\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eInrush current limited to 12 times peak primary current\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eSingle-Phase Isolating Transformer for Hospitals\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\u003ctd\u003e230V AC (230-230V range)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\u003ctd\u003e230V AC with centre tap (230-230V range)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Apparent Power\u003c\/td\u003e\u003ctd\u003e6.3 kVA (6300 VA)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInsulation Class\u003c\/td\u003e\u003ctd\u003eH (180°C)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP21\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e340 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e410 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e370 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Flexible Cable Terminal\u003c\/td\u003e\u003ctd\u003e35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Flexible Cable Terminal\u003c\/td\u003e\u003ctd\u003e35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelative Short Circuit Voltage\u003c\/td\u003e\u003ctd\u003e2.8%\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary\/Earth Leakage Current\u003c\/td\u003e\u003ctd\u003e0.5 mA off-load (maximum)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInrush Current Limit\u003c\/td\u003e\u003ctd\u003e12 times peak primary current\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTemperature Monitoring Systems\u003c\/td\u003e\u003ctd\u003eBi-metal strips and PT100 thermocouple\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eElectrostatic Shield\u003c\/td\u003e\u003ctd\u003eYes, with dedicated terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit-Proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRing Core\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSuitable for PCB Mounting\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSuitable for Distribution Board\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCompliance Standard\u003c\/td\u003e\u003ctd\u003eIEC EN 61558-2-15\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e042574\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245060425746\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eManufacturer\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand Single-Phase Isolating Transformer Hospital IP21 6.3kVA | 42574 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45140996391112,"sku":"042574","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/6a1619e4-f3b3-4e39-b9d3-8187933db273.webp?v=1784069094","url":"https:\/\/toolmart.me\/en\/products\/legrand-single-phase-isolating-transformer-hospital-ip21-6-3kva-042574","provider":"TOOLMART","version":"1.0","type":"link"}