{"product_id":"legrand-single-phase-isolating-transformer-hospital-2-5kva-230v-042591","title":"Legrand Single-Phase Isolating Transformer Hospital 2.5kVA 230V | 42591","description":"\u003cp\u003eShop Legrand Single-Phase Isolating Transformer Hospital 2.5kVA 230V | 42591 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Hospital-grade single-phase isolating transformer with 2.5kVA output, dual temperature monitoring, and advanced safety features compliant with IEC EN 61558-2-15 standard for critical medical applications.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n This Legrand isolating transformer is specifically designed for hospital applications, conforming to the stringent requirements of IEC EN 61558-2-15 standard. The transformer features advanced safety specifications including a secondary\/earth leakage current limited to 0.5 mA off-load and inrush current restricted to 12 times the peak value of primary current. It is equipped with an electrostatic shield connected to a dedicated terminal, ensuring maximum protection and safety for sensitive medical equipment.\n \n The transformer is furnished with dual temperature monitoring systems comprising both bi-metal strips and a thermocouple PT 100 sensor, making it fully compatible with any medical control system. With an IP 00 protection rating and a 2.5 kVA output capacity, this single-phase unit operates with primary and secondary voltages of 230V. The flexible cable terminals accommodate 16 mm² cross-sections on both primary and secondary sides, providing robust electrical connections suitable for demanding hospital environments.\n \n This isolating transformer represents the highest standards in electrical safety and reliability for medical facility applications, offering protection against electrical hazards while maintaining consistent power delivery to critical hospital equipment. The comprehensive technical specifications and compliance certifications ensure peace of mind for healthcare facility managers and engineers.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eDual temperature monitoring systems with bi-metal strips and PT 100 thermocouple for comprehensive thermal protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSecondary\/earth leakage current limited to 0.5 mA off-load for enhanced electrical safety\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eInrush current restricted to 12 times peak primary current value for equipment protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eElectrostatic shield with dedicated terminal connection for noise reduction and EMI protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eFull compliance with IEC EN 61558-2-15 hospital safety standard for medical applications\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eSingle-Phase Isolating Transformer\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\u003ctd\u003e230V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\u003ctd\u003e230V AC with centre tap\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Apparent Power\u003c\/td\u003e\u003ctd\u003e2.5 kVA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP 00\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e300 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e292 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e171 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Terminal Cable\u003c\/td\u003e\u003ctd\u003eFlexible cable 16 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Terminal Cable\u003c\/td\u003e\u003ctd\u003eFlexible cable 16 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eType of Insulation Material\u003c\/td\u003e\u003ctd\u003eClass B (IEC 85)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelative Short Circuit Voltage\u003c\/td\u003e\u003ctd\u003e3.1%\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit-Proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRing Core\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary\/Earth Leakage Current\u003c\/td\u003e\u003ctd\u003e0.5 mA off-load\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInrush Current\u003c\/td\u003e\u003ctd\u003eLimited to 12 times peak primary current\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTemperature Monitoring\u003c\/td\u003e\u003ctd\u003eBi-metal strips and thermocouple PT 100\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCompliance Standard\u003c\/td\u003e\u003ctd\u003eIEC EN 61558-2-15\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eApplication\u003c\/td\u003e\u003ctd\u003eHospital medical equipment\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eManufacturer\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand Single-Phase Isolating Transformer Hospital 2.5kVA 230V | 42591 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45140996554952,"sku":"042591","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/888e4624-6c91-489d-b47a-99ef6d7c17be.webp?v=1784069119","url":"https:\/\/toolmart.me\/en\/products\/legrand-single-phase-isolating-transformer-hospital-2-5kva-230v-042591","provider":"TOOLMART","version":"1.0","type":"link"}