{"product_id":"legrand-rtx3-100-thermal-overload-relay-63-85a-class-10a-416729","title":"Legrand RTX3 100 Thermal Overload Relay 63-85A Class 10A | 416729","description":"\u003cp\u003eShop Legrand RTX3 100 Thermal Overload Relay 63-85A Class 10A | 416729 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Legrand RTX3 100 thermal overload relay with 63-85A adjustable current range, Class 10A protection, 1NO+1NC auxiliary contacts, and direct CTX3 contactor attachment for reliable motor protection in industrial applications.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand RTX3 100 Thermal Overload Relay is a precision-engineered protective device designed for three-phase asynchronous motor protection in tertiary and industrial installations. With an adjustable current range of 63-85A and Class 10A release characteristics, this relay provides reliable overload protection with automatic or manual reset capabilities. The device features direct attachment mounting to CTX3 contactors, making it an ideal solution for comprehensive motor control systems.\n \n This thermal overload relay incorporates advanced safety features including 1NO + 1NC auxiliary contacts rated at 0.75A\/240V AC, screw terminals accommodating power cables from 16mm² to 25mm², and auxiliary circuit connections up to 1mm². The reset button selector offers flexible operation modes, while the integrated trip indicator and stop\/test button provide clear visual feedback and convenient testing capabilities. The RTX3 100 is engineered to withstand demanding industrial environments and deliver consistent performance.\n \n With a maximum rated operation voltage of 690V and screw connection terminals for the main circuit, this relay meets international standards for motor protection. The device can be mounted independently using the optional RTX3 separate mounting unit, offering installation flexibility for various applications. Ideal for protecting motors in industrial facilities, manufacturing plants, and commercial installations, the RTX3 100 ensures equipment longevity and operational safety.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eAdjustable current range 63-85A with Class 10A release characteristics\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e1NO + 1NC auxiliary contacts rated 0.75A\/240V AC for reliable signaling\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDirect attachment mounting to CTX3 contactors for integrated motor control\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eReset button selector with automatic or manual reset modes for operational flexibility\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eTrip indicator and stop\/test button for visual feedback and convenient testing\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eScrew terminals accommodating power cables 16-25mm² and auxiliary circuits 1mm²\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eMaximum rated operation voltage 690V for industrial applications\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIndependent mounting capability with optional RTX3 separate mounting unit\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDesigned for tertiary and industrial installations with proven reliability\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eComprehensive motor protection in demanding industrial environments\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Name\u003c\/td\u003e\u003ctd\u003eThermal Overload Relay RTX3 100\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eManufacturer\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e416729\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3414970406835\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdjustable Current Range\u003c\/td\u003e\u003ctd\u003e63-85 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelease Class\u003c\/td\u003e\u003ctd\u003eCLASS 10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMaximum Rated Operation Voltage\u003c\/td\u003e\u003ctd\u003e690 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAuxiliary Contacts - Normally Open\u003c\/td\u003e\u003ctd\u003e1 NO\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAuxiliary Contacts - Normally Closed\u003c\/td\u003e\u003ctd\u003e1 NC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAuxiliary Contact Rating\u003c\/td\u003e\u003ctd\u003e0.75A \/ 240V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePower Circuit Screw Terminal Capacity\u003c\/td\u003e\u003ctd\u003e16mm² to 25mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAuxiliary Circuit Screw Terminal Capacity\u003c\/td\u003e\u003ctd\u003e1mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMain Circuit Connection Type\u003c\/td\u003e\u003ctd\u003eScrew Connection\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDirect Attachment to CTX3 Contactor\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eIndependent Mounting\u003c\/td\u003e\u003ctd\u003ePossible with RTX3 Separate Mounting Unit (Cat No 416595)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReset Options\u003c\/td\u003e\u003ctd\u003eAutomatic or Manual Reset\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eControl Features\u003c\/td\u003e\u003ctd\u003eTrip Indicator, Stop\/Test Button\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eApplication\u003c\/td\u003e\u003ctd\u003eThree-Phase Asynchronous Motor Protection\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInstallation Type\u003c\/td\u003e\u003ctd\u003eTertiary and Industrial Installations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStandards Compliance\u003c\/td\u003e\u003ctd\u003eInternational Motor Protection Standards\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand RTX3 100 Thermal Overload Relay 63-85A Class 10A | 416729 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45150109008072,"sku":"416729","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/1cecd2d4-8564-49cb-92c2-363eccc9bf39.webp?v=1784989080","url":"https:\/\/toolmart.me\/en\/products\/legrand-rtx3-100-thermal-overload-relay-63-85a-class-10a-416729","provider":"TOOLMART","version":"1.0","type":"link"}