{"product_id":"legrand-mpx3-motor-protection-circuit-breaker-18-26a-50ka","title":"Legrand MPX3 Motor Protection Circuit Breaker 18-26A 50KA | 417364","description":"\u003cp\u003eShop Legrand MPX3 Motor Protection Circuit Breaker 18-26A 50KA | 417364 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Compact motor protection circuit breaker with adjustable 18-26A thermal-magnetic protection and 50kA breaking capacity for 3-phase motors up to 11kW, ideal for HVAC and industrial applications.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand MPX³ motor circuit breaker is a compact and reliable solution designed for the protection, control, and isolation of 3-phase motors up to 11kW at 415V. This advanced device features adjustable thermal-magnetic protection with a current setting range of 18A to 26A, providing precise motor overload protection. With a rated short-circuit breaking capacity of 50kA at 400V AC, the MPX3 63H is engineered to handle demanding HVAC and industrial applications with exceptional performance and durability.\n \n The MPX³ motor circuit breaker incorporates a reduced footprint design that optimizes cabinet space utilization, making it ideal for tertiary and industrial installations. The device features a rotary handle for easy operation, integrated auxiliary switch, and integrated under-voltage release for enhanced safety and control. Its cage terminals accommodate conductors from 0.75mm² to 35mm² (or 2 x 0.75mm² to 25mm²), ensuring flexible installation options. The thermomagnetic switching-off technique provides reliable protection against both overload and short-circuit conditions.\n \n This motor protection circuit breaker meets all substance-restriction requirements and has been designed with environmental consciousness. Compatible with MPX3 auxiliaries, it can be mounted on 35mm top-hat mounting rails (IEC 60715) or mounting plates. The device operates at rated voltages between 220-690V and delivers rated operation power of 5.5kW at 230V (AC-3) or 11kW at 400V (AC-3), making it the perfect choice for modern industrial motor protection applications.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eAdjustable thermal-magnetic protection with 18-26A current setting range\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e50kA short-circuit breaking capacity at 400V AC for superior protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompact reduced footprint design optimizes cabinet space utilization\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIntegrated auxiliary switch and under-voltage release for enhanced safety\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with MPX3 auxiliaries and flexible mounting options\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eRotary handle for easy and intuitive operation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCage terminals accommodate 0.75mm² to 35mm² conductors\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSuitable for 3-phase motors up to 11kW at 415V\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eOperates at rated voltages from 220-690V\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eEnvironmentally conscious design with substance-restriction compliance\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eMotor Protection Circuit Breaker\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBrand\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModel\u003c\/td\u003e\u003ctd\u003eMPX3 63H\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e417364\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3414970396075\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOverload Release Current Setting (Min-Max)\u003c\/td\u003e\u003ctd\u003e18-26 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eUndelayed Short-Circuit Release Adjustment Range\u003c\/td\u003e\u003ctd\u003e338-338 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eThermal Overload Protection\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePhase Failure Sensitive\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSwitch-Off Technique\u003c\/td\u003e\u003ctd\u003eThermomagnetic\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Operating Voltage (Min-Max)\u003c\/td\u003e\u003ctd\u003e220-690 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Permanent Current Iu\u003c\/td\u003e\u003ctd\u003e26 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Operation Power at AC-3, 230V\u003c\/td\u003e\u003ctd\u003e5.5 kW\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Operation Power at AC-3, 400V\u003c\/td\u003e\u003ctd\u003e11 kW\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eType of Electrical Connection\u003c\/td\u003e\u003ctd\u003eFrame Clamp\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eControl Element Type\u003c\/td\u003e\u003ctd\u003eTurn Button\/Rotary Handle\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDevice Construction\u003c\/td\u003e\u003ctd\u003eBuilt-in Device Fixed Built-in Technique\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eIntegrated Auxiliary Switch\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eIntegrated Under-Voltage Release\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Short-Circuit Breaking Capacity Icu at 400V AC\u003c\/td\u003e\u003ctd\u003e50 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Short-Circuit Making Capacity Ics at 400V AC\u003c\/td\u003e\u003ctd\u003e50 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection (IP)\u003c\/td\u003e\u003ctd\u003eIP20\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e140 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e55 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e144.6 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConductor Capacity (Single)\u003c\/td\u003e\u003ctd\u003e0.75mm² to 35mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConductor Capacity (Double)\u003c\/td\u003e\u003ctd\u003e2 x 0.75mm² to 25mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Type\u003c\/td\u003e\u003ctd\u003e35mm Top-Hat Rail (IEC 60715) or Mounting Plate\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMotor Protection Class\u003c\/td\u003e\u003ctd\u003e3-Phase Motors up to 11kW\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand MPX3 Motor Protection Circuit Breaker 18-26A 50KA | 417364 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45150101110984,"sku":"417364","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/f180d04b-fe7e-4c10-89c2-1b967921a779.webp?v=1784987967","url":"https:\/\/toolmart.me\/en\/products\/legrand-mpx3-motor-protection-circuit-breaker-18-26a-50ka","provider":"TOOLMART","version":"1.0","type":"link"}