{"product_id":"legrand-mcb-tx3-10000a-3-pole-25a-curve-b-404128","title":"Legrand MCB TX3 10000A 3 Pole 25A Curve B Circuit Breaker | 404128","description":"\u003cp\u003eShop Legrand MCB TX3 10000A 3 Pole 25A Curve B Circuit Breaker | 404128 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Advanced 3-pole thermal magnetic circuit breaker with 10kA breaking capacity, B-curve tripping, and IP20 protection for reliable electrical installation safeguarding\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand MCB TX3 10000A is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. With a breaking capacity of 10kA at 400V, this 3-pole device features a B-curve tripping characteristic with a threshold between 75A and 125A (3-5 times the rated current). The MCB can be supplied via copper cable, prong busbar (top or bottom side), or fork busbar (bottom side), making it versatile for various installation configurations.\n \n This circuit breaker is equipped with advanced safety features including IP20 protection against solid bodies larger than 12.5mm (fingerproof), maximum energy limitation class 3 according to IEC 60898-1 standard, and compatibility with Legrand DX3 auxiliaries and accessories. The device can also be connected to aluminium cable using Legrand DX3 terminal accessory. With a rated current of 25A and rated voltage of 400V, it provides reliable protection for residential and small commercial applications.\n \n The MCB TX3 features a special DIN rail clamp on the bottom side allowing independent removal even when the fork busbar is still in place. It includes a convenient label holder for circuit identification and clear ON\/OFF indication printed on the handle with red and green backgrounds. The device complies with substance-restriction requirements and has been designed following environmentally conscious processes, making it an eco-friendly choice for modern electrical installations.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003e10kA breaking capacity at 400V according to IEC 60898-1 standard for household and small commercial installations\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eB-curve tripping characteristic with threshold between 75A and 125A (3-5 times rated current) for optimal protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 protection against solid bodies larger than 12.5mm with maximum energy limitation class 3\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with Legrand DX3 auxiliaries and accessories for enhanced functionality and customization\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eVersatile supply options including copper cable, prong busbar, and fork busbar connections\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIndependent removal capability with special DIN rail clamp allowing removal without disturbing busbar\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eClear circuit identification with integrated label holder and ON\/OFF indication on handle\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eEnvironmentally conscious design complying with substance-restriction requirements and RoHS directives\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eThermal Magnetic Circuit Breaker (MCB)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBrand\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModel\u003c\/td\u003e\u003ctd\u003eTX3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e404128\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3414970392732\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e3 poles\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e25A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\u003ctd\u003e500V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\u003ctd\u003e4kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity (Icn) at 230V\u003c\/td\u003e\u003ctd\u003e16kA according to EN 60898\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity (Icn) at 400V\u003c\/td\u003e\u003ctd\u003e10kA according to EN 60898\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\u003ctd\u003eB-curve (75A-125A or 3-5 In)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCurrent Limiting Class\u003c\/td\u003e\u003ctd\u003eClass 3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency Range\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection (IP)\u003c\/td\u003e\u003ctd\u003eIP20\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpact Strength (IK)\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth (Modular Units)\u003c\/td\u003e\u003ctd\u003e3 modules\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e53.1mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e88mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e77.8mm (44mm built-in depth)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColor\u003c\/td\u003e\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN Rail\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed terminal, Busbar and cable\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSupply Direction\u003c\/td\u003e\u003ctd\u003eTop or bottom\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNominal Voltage Range\u003c\/td\u003e\u003ctd\u003e240-415V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNeutral Conductor Switching\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eLabel Space\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eExplosion-proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand MCB TX3 10000A 3 Pole 25A Curve B Circuit Breaker | 404128 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45159426392264,"sku":"404128","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/057f18d5-d800-42cf-860e-d07797a50b17.webp?v=1785763699","url":"https:\/\/toolmart.me\/en\/products\/legrand-mcb-tx3-10000a-3-pole-25a-curve-b-404128","provider":"TOOLMART","version":"1.0","type":"link"}