{"product_id":"legrand-isolating-transformer-hospital-5kva-ip21-042573","title":"Legrand IP21 Single Phase Hospital Isolating Transformer 5kVA | 42573","description":"\u003cp\u003eShop Legrand IP21 Single Phase Hospital Isolating Transformer 5kVA | 42573 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Legrand hospital-grade isolating transformer with 5 kVA capacity, dual temperature monitoring, IP21 protection, and compliance with IEC EN 61558-2-15 standard for medical applications.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n This Legrand isolating transformer model 042573 is specifically designed for hospital applications and conforms to the rigorous IEC EN 61558-2-15 standard. The transformer features a single-phase configuration with primary and secondary voltages of 230V~, making it ideal for medical environments requiring enhanced safety and isolation. With a rated apparent power of 5 kVA, this transformer is equipped with dual temperature monitoring systems including bi-metal strips and thermocouple PT 100 sensors, ensuring compatibility with any medical control system. The IP21 protection rating provides reliable protection against water spray and dust ingress, critical for hospital environments.\n \n The transformer incorporates an electrostatic shield linked to a dedicated terminal, which helps minimize electromagnetic interference and ensures patient safety. It features secondary\/earth leakage current limited to 0.5 mA off-load and inrush current restricted to 12 times the peak value of primary current, both crucial specifications for medical applications. The unit comes with flexible cable terminals rated at 35 mm² for both primary and secondary connections, allowing for flexible installation in various hospital configurations. The H-class insulation material provides excellent thermal stability and long-term reliability.\n \n With dimensions of 340mm (width) × 410mm (height) × 370mm (depth), this transformer is compact enough for efficient space utilization in hospital installations. The 3.1% relative short circuit voltage ensures minimal voltage drop during operation, maintaining stable power delivery to critical medical equipment. This transformer is non-ring core and not suitable for PCB or distribution board mounting, making it ideal for standalone installation in medical facilities.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eIEC EN 61558-2-15 compliant isolating transformer designed specifically for hospital environments\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDual temperature monitoring systems with bi-metal strips and thermocouple PT 100 sensors for medical control system compatibility\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP21 protection rating providing resistance to water spray and dust ingress\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eElectrostatic shield linked to dedicated terminal minimizing electromagnetic interference\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eEarth leakage current limited to 0.5 mA off-load with inrush current restricted to 12 times peak primary current\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eH-class insulation material ensuring excellent thermal stability and long-term reliability\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e35 mm² flexible cable terminals for both primary and secondary connections\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompact dimensions (340×410×370 mm) suitable for efficient space utilization\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e3.1% relative short circuit voltage ensuring minimal voltage drop\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSingle-phase configuration with 230V primary and secondary voltages\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eIsolating Transformer for Hospitals\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModel Number\u003c\/td\u003e\u003ctd\u003e042573\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eManufacturer\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePhase Configuration\u003c\/td\u003e\u003ctd\u003eSingle-phase\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\u003ctd\u003e230V~ (Min-Max: 230-230V)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\u003ctd\u003e230V~ with centre tap (Min-Max: 230-230V)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Apparent Power\u003c\/td\u003e\u003ctd\u003e5000 VA (5 kVA)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInsulation Class\u003c\/td\u003e\u003ctd\u003eH (IEC 85)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP21\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelative Short Circuit Voltage\u003c\/td\u003e\u003ctd\u003e3.1%\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e340 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e410 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e370 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Terminal Cable Size\u003c\/td\u003e\u003ctd\u003e35 mm² (flexible)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Terminal Cable Size\u003c\/td\u003e\u003ctd\u003e35 mm² (flexible)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTemperature Monitoring\u003c\/td\u003e\u003ctd\u003eDual system with bi-metal strips and thermocouple PT 100\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEarth Leakage Current\u003c\/td\u003e\u003ctd\u003eLimited to 0.5 mA off-load\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInrush Current\u003c\/td\u003e\u003ctd\u003eLimited to 12 times peak primary current\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSafety Transformer\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEnergy Saving Transformer\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-circuit Proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRing Core\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePCB Mounting Compatible\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDistribution Board Mounting\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStandards Compliance\u003c\/td\u003e\u003ctd\u003eIEC EN 61558-2-15\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245060425739\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand IP21 Single Phase Hospital Isolating Transformer 5kVA | 42573 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45140996358344,"sku":"042573","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/36f326f3-dc8a-40e0-8e9d-aa5c77baa6de.webp?v=1784069089","url":"https:\/\/toolmart.me\/en\/products\/legrand-isolating-transformer-hospital-5kva-ip21-042573","provider":"TOOLMART","version":"1.0","type":"link"}