{"product_id":"legrand-isolating-transformer-hospital-10kva-single-phase-042596","title":"Legrand Isolating Transformer Hospital 10kVA Single Phase 230V | 42596","description":"\u003cp\u003eShop Legrand Isolating Transformer Hospital 10kVA Single Phase 230V | 42596 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Medical-grade isolating transformer for hospitals with dual temperature monitoring, 10kVA output, IEC EN 61558-2-15 compliant, featuring electrostatic shield and dedicated safety terminals.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand Isolating Transformer for Hospitals is a specialized medical-grade transformer designed to meet the stringent requirements of IEC EN 61558-2-15 standard. This single-phase transformer features a primary voltage of 230V and secondary voltage of 230V with center tap, delivering a rated output of 10kVA. It is specifically engineered for hospital environments where patient safety and electrical isolation are critical requirements. The transformer incorporates dual temperature monitoring systems including bi-metal strips and thermocouple PT 100 sensors, making it fully compatible with any medical control system.\n \n This isolating transformer is equipped with an electrostatic shield linked to dedicated terminals, ensuring superior electromagnetic compatibility and safety. The device meets strict secondary\/earth leakage current limitations of 0.5mA off-load and controls inrush current to 12 times the peak value of primary current. With IP00 degree of protection and flexible cable terminals (35mm² for both primary and secondary), this transformer provides reliable electrical isolation for critical medical applications. The H-type insulation material ensures durability and thermal performance in demanding hospital environments.\n \n The transformer's design emphasizes safety and reliability with dedicated output terminals for temperature monitoring systems. Its robust construction and compliance with international medical standards make it an ideal choice for hospitals requiring secure electrical isolation for sensitive medical equipment and patient care areas.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eDual Temperature Monitoring Systems - Bi-metal strips and thermocouple PT 100 sensors for complete medical system compatibility\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eElectrostatic Shield with Dedicated Terminals - Superior electromagnetic compatibility and safety isolation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIEC EN 61558-2-15 Compliant - Meets strict international medical transformer standards\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSecondary\/Earth Leakage Current Limited to 0.5mA - Enhanced patient safety and equipment protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eControlled Inrush Current - Limited to 12 times peak primary current value for equipment protection\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eIsolating Transformer for Hospitals\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eManufacturer\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e042596\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3414970971470\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePhase Configuration\u003c\/td\u003e\u003ctd\u003eSingle Phase\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\u003ctd\u003e230V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\u003ctd\u003e230V AC with Centre Tap\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Apparent Power\u003c\/td\u003e\u003ctd\u003e10,000 VA (10 kVA)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInsulation Material Type\u003c\/td\u003e\u003ctd\u003eType H (IEC 85)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP00\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e290 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e420 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e220 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Flexible Cable Terminal\u003c\/td\u003e\u003ctd\u003e35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Flexible Cable Terminal\u003c\/td\u003e\u003ctd\u003e35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelative Short Circuit Voltage\u003c\/td\u003e\u003ctd\u003e3.6%\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary\/Earth Leakage Current\u003c\/td\u003e\u003ctd\u003e0.5 mA (off-load maximum)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInrush Current Limitation\u003c\/td\u003e\u003ctd\u003e12 times peak primary current\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTemperature Monitoring\u003c\/td\u003e\u003ctd\u003eBi-metal strips and Thermocouple PT 100\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCompliance Standard\u003c\/td\u003e\u003ctd\u003eIEC EN 61558-2-15\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSafety Features\u003c\/td\u003e\u003ctd\u003eElectrostatic shield with dedicated terminals\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit Proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRing Core\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSuitable for PCB Mounting\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSuitable for Distribution Board\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand Isolating Transformer Hospital 10kVA Single Phase 230V | 42596 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45140996718792,"sku":"042596","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/6b631d14-9be0-439e-b707-39089f7a33bb.webp?v=1784069145","url":"https:\/\/toolmart.me\/en\/products\/legrand-isolating-transformer-hospital-10kva-single-phase-042596","provider":"TOOLMART","version":"1.0","type":"link"}