{"product_id":"legrand-dx3-mcb-6000a-3-pole-50a-circuit-breaker-407864","title":"Legrand DX3 MCB 3 Pole 50A Circuit Breaker Type C | 407864","description":"\u003cp\u003eShop Legrand DX3 MCB 3 Pole 50A Circuit Breaker Type C | 407864 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Thermal magnetic 3-pole 50A circuit breaker with 10kA breaking capacity, C-curve protection, IP20 finger-safe design, and DIN rail mounting for reliable electrical installation protection\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand DX3 MCB 6000A is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits with exceptional reliability. This 3-pole, 50A C-curve breaker features a 10kA breaking capacity at 400V and is certified according to IEC 60898-1 standards for household installations. The device provides maximum energy limitation with class 3 current limiting capability, ensuring superior protection for your electrical system. Its IP20 finger-safe design protects against solid bodies larger than 12.5mm, making it safe for residential and commercial applications. The breaker can be supplied via copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar, offering flexible installation options. With DIN rail mounting and a built-in depth of 44mm, this compact yet powerful device integrates seamlessly into residential and small commercial panels.\n \n The MCB DX3 features an intelligent tripping threshold for short-circuits between 250A and 500A (C curve between 5In and 10In), providing precise protection against electrical faults. It can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories to enhance functionality. The device is compatible with aluminium cables using terminal accessory number 4063 10, extending its applicability. Its label holder allows clear circuit identification, while the ON\/OFF indication printed on the handle with red and green backgrounds ensures easy status recognition. Operating at frequencies between 50-60 Hz, the breaker maintains consistent performance across different electrical systems. The environmentally conscious design complies with substance-restriction requirements, making it an eco-friendly choice for modern electrical installations.\n \n With rated insulation voltage of 500V and impulse withstand voltage of 4kV, this circuit breaker offers robust protection against voltage spikes and transient events. The device supports multi-wired conductors from 1.5-25mm² and solid-core conductors from 1.5-35mm², accommodating various cable sizes. Its halogen-free composition and compliance with RoHS and REACH directives demonstrate Legrand's commitment to environmental responsibility. The breaker operates reliably across ambient temperatures from -25°C to 70°C, with storage capability from -40°C to 70°C, ensuring performance in diverse climatic conditions.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eThermal magnetic protection with 10kA breaking capacity at 400V for reliable fault detection and interruption\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eC-curve tripping characteristic (250A-500A short-circuit threshold) ensures precise protection against electrical faults\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 finger-safe design protects against solid bodies larger than 12.5mm, meeting IEC\/EN 60529 standards\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eClass 3 energy limitation provides maximum let-through energy control and arc flash protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDIN rail mounting with dual clamps allows independent removal without disturbing power supply\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with multiple supply options including copper cable, prong busbar, fork busbar, and HX3 plug busbar\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIntegrated label holder and ON\/OFF indication with color-coded handle for easy circuit identification\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eExpandable with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eHalogen-free construction with RoHS and REACH compliance for environmental responsibility\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eWide operating temperature range (-25°C to 70°C) ensures reliable performance in diverse climates\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Name\u003c\/td\u003e\u003ctd\u003eMCB DX3 6000A 3 Pole 50A Curve C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e407864\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245064078641\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eManufacturer\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e50 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e3 poles\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelease Characteristic\u003c\/td\u003e\u003ctd\u003eC curve\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400 V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\u003ctd\u003e500 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\u003ctd\u003e4 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Short-Circuit Breaking Capacity (Icn) at 400V\u003c\/td\u003e\u003ctd\u003e6 kA according to IEC 60898-1\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Short-Circuit Breaking Capacity (Icu) at 230V\u003c\/td\u003e\u003ctd\u003e25 kA according to IEC 60947-2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Short-Circuit Breaking Capacity (Icu) at 400V\u003c\/td\u003e\u003ctd\u003e10 kA according to IEC 60947-2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit Tripping Threshold\u003c\/td\u003e\u003ctd\u003e250A to 500A (C curve between 5In and 10In)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCurrent Limiting Class\u003c\/td\u003e\u003ctd\u003eClass 3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency Range\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP20 (finger-safe)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBuilt-in Depth\u003c\/td\u003e\u003ctd\u003e44 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e53.1 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e94.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTotal Depth\u003c\/td\u003e\u003ctd\u003e77.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth in Modular Spacings\u003c\/td\u003e\u003ctd\u003e3 modules\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Impact Strength\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section (Multi-wired)\u003c\/td\u003e\u003ctd\u003e1.5-25 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section (Solid-core)\u003c\/td\u003e\u003ctd\u003e1.5-35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSupply Direction\u003c\/td\u003e\u003ctd\u003eBy the top or bottom\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN rail with dual clamps\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConcurrently Switching Neutral Conductor\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes (DX3 auxiliaries, RCD add-on modules, accessories)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAmbient Temperature During Operating\u003c\/td\u003e\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature\u003c\/td\u003e\u003ctd\u003e-40°C to 70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColour\u003c\/td\u003e\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eExplosion-proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eLabel Space\/Information Surface\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCarbon Footprint (Manufacturing Phase)\u003c\/td\u003e\u003ctd\u003e3.076 kg CO₂ eq.\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStandards Compliance\u003c\/td\u003e\u003ctd\u003eIEC 60898-1, IEC 60947-2, IEC\/EN 60529, RoHS, REACH\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAluminium Cable Compatibility\u003c\/td\u003e\u003ctd\u003eYes (with terminal accessory 4063 10)\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand DX3 MCB 3 Pole 50A Circuit Breaker Type C | 407864 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45159433011400,"sku":"407864","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/2dd14d53-ee25-4c77-bd22-570199eb05d2.webp?v=1785764578","url":"https:\/\/toolmart.me\/en\/products\/legrand-dx3-mcb-6000a-3-pole-50a-circuit-breaker-407864","provider":"TOOLMART","version":"1.0","type":"link"}