{"product_id":"legrand-dx3-mcb-4p-32a-6ka-circuit-breaker-b-curve-407627","title":"Legrand DX3 MCB 4P 32A 6kA Circuit Breaker B Curve | 407627","description":"\u003cp\u003eShop Legrand DX3 MCB 4P 32A 6kA Circuit Breaker B Curve | 407627 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Legrand DX3 4-pole 32A thermal magnetic circuit-breaker with 6kA breaking capacity, B-curve characteristic, and advanced protection for residential and commercial installations.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand DX3 MCB 407627 is a thermal magnetic circuit-breaker specifically designed to protect wiring installations against overloads and short-circuits. With a 4-pole configuration, 32A rated current, and 400V AC voltage, this device provides reliable protection for residential and small commercial applications. The B-curve characteristic ensures optimal tripping performance between 3 and 5 times the rated current, making it ideal for general-purpose circuits with standard loads.\n \n This circuit-breaker features a 6kA breaking capacity according to IEC 60898-1 standard for household installations, with enhanced 10kA breaking capacity at 400V according to IEC 60947-2. The device is equipped with DIN rail clamps for secure mounting, allowing independent removal without disturbing the prong busbar. With IP20 protection rating against solid bodies larger than 12.5mm, it meets fingerproof safety standards. The unit can be supplied via copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar connections.\n \n The DX3 MCB incorporates advanced energy limitation class 3 technology to minimize let-through energy during short-circuit events. It can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories for enhanced functionality. The device complies with all substance-restriction requirements and has been manufactured using environmentally conscious processes. With a built-in label holder for circuit identification and clear ON\/OFF indication on the handle, this circuit-breaker ensures safe, reliable operation and easy maintenance.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003e4-pole configuration with 32A rated current at 400V AC for comprehensive circuit protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eB-curve characteristic with tripping threshold between 96A and 160A (3-5 times rated current) for optimal performance\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e6kA breaking capacity per IEC 60898-1 with enhanced 10kA capacity at 400V per IEC 60947-2\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eEnergy limitation class 3 technology to minimize let-through energy during short-circuit events\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 fingerproof protection against solid bodies larger than 12.5mm with DIN rail mounting\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with Legrand DX3 auxiliaries, RCD add-on modules, and comprehensive accessories\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDual DIN rail clamps for independent removal without disturbing prong busbar connections\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eBuilt-in label holder and clear ON\/OFF indication for easy circuit identification and status monitoring\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSupports multiple connection types including copper cable, prong busbar, fork busbar, and HX3 plug busbar\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eEnvironmentally conscious design compliant with substance-restriction requirements and RoHS directive\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eThermal Magnetic Circuit Breaker (MCB)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBrand\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModel Series\u003c\/td\u003e\u003ctd\u003eDX3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e407627\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245064076272\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e4 poles (4P)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e32 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400 V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\u003ctd\u003e500 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\u003ctd\u003e4 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eVoltage Type\u003c\/td\u003e\u003ctd\u003eAC (Alternating Current)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency Range\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity (Icn)\u003c\/td\u003e\u003ctd\u003e6 kA at 400V per IEC 60898-1\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity (Icu)\u003c\/td\u003e\u003ctd\u003e10 kA at 400V per IEC 60947-2, 25 kA at 230V per IEC 60947-2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelease Characteristic\u003c\/td\u003e\u003ctd\u003eB Curve (3-5 times rated current)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTripping Threshold\u003c\/td\u003e\u003ctd\u003e96A to 160A for short-circuit (B curve between 3 In and 5 In)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCurrent Limiting Class\u003c\/td\u003e\u003ctd\u003eClass 3 (Maximum energy limitation)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP20 (Fingerproof against solid bodies \u003e 12.5mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Impact Strength\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBuilt-in Depth\u003c\/td\u003e\u003ctd\u003e44 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth (Modular Spacing)\u003c\/td\u003e\u003ctd\u003e4 modules\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e70.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e94.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e77.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColour\u003c\/td\u003e\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section (Multi-wired)\u003c\/td\u003e\u003ctd\u003e1.5-25 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section (Solid-core)\u003c\/td\u003e\u003ctd\u003e1.5-35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed Terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eElectric Supplying Direction\u003c\/td\u003e\u003ctd\u003eBy the top or bottom\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN Rail\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConcurrently Switching Neutral Conductor\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes (DX3 auxiliaries, RCD add-on modules, accessories)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAmbient Temperature (Operating)\u003c\/td\u003e\u003ctd\u003e-25 to +70 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature\u003c\/td\u003e\u003ctd\u003e-40 to +70 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eExplosion-proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eLabel Space\/Information Surface\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCarbon Footprint (Manufacturing Phase A1-A3)\u003c\/td\u003e\u003ctd\u003e3.595 kg CO₂ eq.\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCompliance Standards\u003c\/td\u003e\u003ctd\u003eIEC 60898-1, IEC 60947-2, IEC\/EN 60529, RoHS Directive, REACH Declaration\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSupply Options\u003c\/td\u003e\u003ctd\u003eCopper cable, prong busbar (top\/bottom), fork busbar (bottom), Legrand HX3 plug busbar (top)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAluminum Cable Compatible\u003c\/td\u003e\u003ctd\u003eYes (with terminal accessory n° 4 063 10)\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand DX3 MCB 4P 32A 6kA Circuit Breaker B Curve | 407627 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45159430815944,"sku":"407627","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/a247f05e-d1be-4e14-b5eb-207894dedba6.webp?v=1785764300","url":"https:\/\/toolmart.me\/en\/products\/legrand-dx3-mcb-4p-32a-6ka-circuit-breaker-b-curve-407627","provider":"TOOLMART","version":"1.0","type":"link"}