{"product_id":"legrand-dx3-mcb-4p-20a-curve-c-10ka-circuit-breaker-409337","title":"Legrand DX3 MCB 4P 20A Curve C Circuit Breaker 10kA | 409337","description":"\u003cp\u003eShop Legrand DX3 MCB 4P 20A Curve C Circuit Breaker 10kA | 409337 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Legrand DX3 thermal magnetic circuit breaker with 4-pole, 20A rating, C curve characteristic, and 10kA breaking capacity. Provides IP20 protection, DIN rail mounting, and complies with IEC 60898-1 standard for reliable electrical system protection.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand DX3 MCB (Miniature Circuit Breaker) is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. With a 4-pole configuration, 20A rated current, and C curve characteristic, this device offers a breaking capacity of 10kA at 400V. The MCB features IP20 safety protection (fingerproof against solid bodies larger than 12.5mm) and is compliant with IEC 60898-1 standard for household installations. The tripping threshold in case of short-circuit ranges between 100A and 200A (C curve between 5 In and 10 In), providing reliable protection for electrical systems.\n \n This circuit breaker is equipped with two DIN rail clamps (top and bottom) allowing independent removal while the prong busbar supplying the row remains in place. It can be supplied by copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar. The device includes a label holder for clear circuit identification and ON\/OFF indication printed on the handle with red and green backgrounds for easy status identification. It achieves maximum energy limitation (class 3 according to IEC 60898-1 standard) and can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and accessories.\n \n The MCB is built with halogen-free materials and has been designed in an environmentally conscious process, complying with substance-restriction requirements. With a built-in depth of 44mm and dimensions of 70.8mm width × 94.8mm height × 77.8mm depth, it occupies 4 modular spacings on DIN rail. The device operates at frequencies of 50-60 Hz and maintains performance across ambient temperatures from -25°C to 70°C. Installation should be performed by a qualified electrician in compliance with local installation rules.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eThermal magnetic protection against overloads and short-circuits with C curve characteristic (5-10 In tripping range)\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eBreaking capacity of 10kA at 400V according to IEC 60898-1 standard for household installations\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 safety rating - fingerproof against solid bodies larger than 12.5mm with maximum energy limitation (class 3)\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e4-pole configuration with concurrent switching of neutral conductor for complete circuit isolation and control\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDIN rail mounted with independent top and bottom clamps allowing removal without disturbing busbar supply\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with copper cable, prong busbar, fork busbar, and Legrand HX3 plug busbar connections\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eLabel holder for clear circuit identification with ON\/OFF indication on handle (red\/green backgrounds)\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eConnectable to aluminum cable with optional terminal accessory for versatile installation options\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCan be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and accessories for expanded functionality\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eHalogen-free construction designed in environmentally conscious process with compliance to substance-restriction requirements\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eMiniature Circuit Breaker (MCB) - Thermal Magnetic\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e4 poles (4P)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e20 Amperes (A)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelease Characteristic\u003c\/td\u003e\u003ctd\u003eC curve (5-10 In tripping range)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400 Volts (V) AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\u003ctd\u003e500 Volts (Ui)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\u003ctd\u003e4 kV (Uimp)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity at 230V\u003c\/td\u003e\u003ctd\u003e16 kA (Icn according to EN 60898)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity at 400V\u003c\/td\u003e\u003ctd\u003e10 kA (Icn according to EN 60898)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eUltimate Breaking Capacity at 230V\u003c\/td\u003e\u003ctd\u003e32 kA (Icu according to IEC 60947-2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eUltimate Breaking Capacity at 400V\u003c\/td\u003e\u003ctd\u003e16 kA (Icu according to IEC 60947-2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency Range\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCurrent Limiting Class\u003c\/td\u003e\u003ctd\u003eClass 3 (maximum energy limitation)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection (IP)\u003c\/td\u003e\u003ctd\u003eIP20 (fingerproof against solid bodies \u003e 12.5mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Impact Strength\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBuilt-in Depth\u003c\/td\u003e\u003ctd\u003e44 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e70.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e94.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOverall Depth\u003c\/td\u003e\u003ctd\u003e77.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModular Width\u003c\/td\u003e\u003ctd\u003e4 modular spacings on DIN rail\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross-Section (Multi-wired)\u003c\/td\u003e\u003ctd\u003e1.5-25 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross-Section (Solid-core)\u003c\/td\u003e\u003ctd\u003e1.5-35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSupply Direction\u003c\/td\u003e\u003ctd\u003eBy the top or bottom\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN rail with independent top and bottom clamps\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConcurrent Switching\u003c\/td\u003e\u003ctd\u003eYes - neutral conductor switched concurrently\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColour\u003c\/td\u003e\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes - compatible with Legrand DX3 auxiliaries, RCD add-on modules, and accessories\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eExplosion-proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eLabel Space\u003c\/td\u003e\u003ctd\u003eYes - label holder included\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e409337\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245064093378\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eApplicable Standards\u003c\/td\u003e\u003ctd\u003eIEC 60898-1, IEC\/EN 60529, IEC 60947-2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCarbon Footprint (Manufacturing)\u003c\/td\u003e\u003ctd\u003e3.704 kg CO₂ eq.\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand DX3 MCB 4P 20A Curve C Circuit Breaker 10kA | 409337 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45172740456648,"sku":"409337","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/542951d3-1aae-4e9e-a5d8-64bea5f1966a.webp?v=1786554362","url":"https:\/\/toolmart.me\/en\/products\/legrand-dx3-mcb-4p-20a-curve-c-10ka-circuit-breaker-409337","provider":"TOOLMART","version":"1.0","type":"link"}