{"product_id":"legrand-dx3-mcb-4p-13a-curve-c-407927","title":"Legrand DX3 MCB 4 Pole 13A Curve C Circuit Breaker | 407927","description":"\u003cp\u003eShop Legrand DX3 MCB 4 Pole 13A Curve C Circuit Breaker | 407927 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n 4-pole thermal magnetic circuit breaker with 13A C curve rating, 6kA breaking capacity, IP20 fingerproof protection, and DIN rail mounting for reliable electrical installation protection.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand DX3 MCB 6000A is a high-performance thermal magnetic circuit breaker designed to protect wiring installations against overloads and short-circuits. With a 4-pole configuration rated at 13A and featuring a C curve characteristic, this device delivers reliable protection for residential and small commercial applications. It offers a breaking capacity of 6kA according to IEC 60898-1 standard for household installations, with a tripping threshold for short-circuits ranging between 65A and 130A. The device is equipped with fingerproof IP20 protection and features DIN rail mounting for easy installation.\n \n This circuit breaker is engineered with advanced energy limitation technology (class 3 according to IEC 60898-1 standard) to minimize let-through energy during fault conditions. The device can be supplied via copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar connections. It features a convenient label holder for circuit identification and clearly marked ON\/OFF positions on the handle with red and green backgrounds for easy status indication. The MCB is compatible with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories for enhanced functionality.\n \n Built to the highest environmental standards, this product is halogen-free and complies with all substance-restriction requirements. It operates reliably across ambient temperatures from -25°C to 70°C and includes dual DIN rail clamps for independent removal without disrupting the main busbar supply. The device accepts solid-core conductors from 1.5-35mm² and multi-wired conductors from 1.5-25mm², providing flexibility for various installation scenarios. With its robust construction, comprehensive protection capabilities, and compliance with international standards, the Legrand DX3 MCB represents an excellent choice for modern electrical installations.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003e6kA breaking capacity according to IEC 60898-1 standard for household installations\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eC curve tripping characteristic between 5In and 10In (65A-130A short-circuit threshold)\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 fingerproof protection against solid bodies larger than 12.5mm\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eEnergy limitation class 3 for maximum let-through energy control\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDIN rail mounting with dual clamps for independent removal\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with Legrand DX3 auxiliaries and RCD add-on modules\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eLabel holder for clear circuit identification\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eON\/OFF indication with red and green background markings\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eHalogen-free and environmentally conscious design\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eAccepts copper and aluminum cables with terminal accessories\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eThermal Magnetic Circuit Breaker\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e4 Pole (4P)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e13 Amperes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelease Characteristic\u003c\/td\u003e\u003ctd\u003eCurve C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\u003ctd\u003e500V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\u003ctd\u003e4 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity (Icn)\u003c\/td\u003e\u003ctd\u003e6 kA at 400V (IEC 60898-1)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity (Icu)\u003c\/td\u003e\u003ctd\u003e10 kA at 400V (IEC 60947-2), 25 kA at 230V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit Tripping Threshold\u003c\/td\u003e\u003ctd\u003e65A to 130A (C curve between 5In and 10In)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCurrent Limiting Class\u003c\/td\u003e\u003ctd\u003e3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency Range\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP20 (Fingerproof)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth in Modular Spacings\u003c\/td\u003e\u003ctd\u003e4 modules\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePhysical Width\u003c\/td\u003e\u003ctd\u003e70.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePhysical Height\u003c\/td\u003e\u003ctd\u003e94.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBuilt-in Depth\u003c\/td\u003e\u003ctd\u003e44 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOverall Depth\u003c\/td\u003e\u003ctd\u003e77.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpact Strength Rating\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN Rail (35mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed Terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section (Solid-core)\u003c\/td\u003e\u003ctd\u003e1.5-35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section (Multi-wired)\u003c\/td\u003e\u003ctd\u003e1.5-25 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColour\u003c\/td\u003e\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConcurrently Switching Neutral Conductor\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes (Auxiliaries, RCD modules)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eLabel Space\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eExplosion-proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSupply Connection\u003c\/td\u003e\u003ctd\u003eBy top or bottom (flexible)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e407927\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245064079273\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCarbon Footprint (Manufacturing)\u003c\/td\u003e\u003ctd\u003e3.397 kg CO₂ eq.\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand DX3 MCB 4 Pole 13A Curve C Circuit Breaker | 407927 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45159433273544,"sku":"407927","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/4d5e270e-9701-43c0-aaeb-7c7a351f922c.webp?v=1785764617","url":"https:\/\/toolmart.me\/en\/products\/legrand-dx3-mcb-4p-13a-curve-c-407927","provider":"TOOLMART","version":"1.0","type":"link"}