{"product_id":"legrand-dx3-mcb-4-pole-40a-curve-d-circuit-breaker-408151","title":"Legrand DX3 MCB 4 Pole 40A Curve D Circuit Breaker | 408151","description":"\u003cp\u003eShop Legrand DX3 MCB 4 Pole 40A Curve D Circuit Breaker | 408151 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Legrand DX3 thermal magnetic 4-pole circuit breaker with 40A rated current, D curve characteristic, and 6000A breaking capacity for reliable protection of residential and small commercial electrical installations.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand DX3 MCB (Miniature Circuit Breaker) is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits while providing control and isolation of electrical installations. This 4-pole device features a 40A rated current with D curve characteristic and 6000A breaking capacity according to IEC 60898-1 standard for household installations. The tripping threshold in case of short-circuit ranges between 400A and 560A (D curve between 10 In and 14 In), making it ideal for residential and small commercial panel applications.\n \n The MCB DX3 can be supplied by copper cable, prong busbar (top or bottom side), fork busbar (bottom side), or Legrand HX3 plug busbar (top side). It is equipped with two DIN rail clamps for independent removal when the prong busbar supplying the row is still in place. The device is protected against solid bodies larger than 12.5mm (fingerproof) with IP20 protection according to IEC\/EN 60529 standard. It features a label holder for clear circuit identification and on\/off indication printed on the handle with red and green backgrounds for easy status identification.\n \n This circuit breaker complies with all substance-restriction requirements and has been designed in an environmentally conscious process. It can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and accessories, and can be connected to aluminum cable with terminal accessory n° 4 063 10. The device operates at 400V AC with rated insulation voltage of 500V and impulse withstand voltage of 4kV.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eBreaking capacity of 6000A according to IEC 60898-1 standard for household installations\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e4-pole configuration with 40A rated current and D curve characteristic for optimal protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eTripping threshold between 400A and 560A for short-circuit protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 protection rating (fingerproof) against solid bodies larger than 12.5mm\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with copper cable, prong busbar, fork busbar, and Legrand HX3 plug busbar\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIndependent removal capability with two DIN rail clamps\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eClear circuit identification with label holder and color-coded on\/off indication\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eEnvironmentally conscious design complying with substance-restriction requirements\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCan be equipped with Legrand DX3 auxiliaries and RCD add-on modules\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eConcurrently switches neutral conductor for enhanced safety\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e4 poles\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e40 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400 V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelease Characteristic\u003c\/td\u003e\u003ctd\u003eD curve\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity (Icn)\u003c\/td\u003e\u003ctd\u003e6 kA at 400 V according to EN 60898\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity (Icu)\u003c\/td\u003e\u003ctd\u003e10 kA at 400 V according to IEC 60947-2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\u003ctd\u003e500 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\u003ctd\u003e4 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency Range\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP20\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBuilt-in Depth\u003c\/td\u003e\u003ctd\u003e44 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e70.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e94.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e77.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth in Modular Spacings\u003c\/td\u003e\u003ctd\u003e4 modules\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section (Multi-wired)\u003c\/td\u003e\u003ctd\u003e1.5-25 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section (Solid-core)\u003c\/td\u003e\u003ctd\u003e1.5-35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\u003ctd\u003e-25 to +70 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\u003ctd\u003e-40 to +70 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpact Strength Degree\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColor\u003c\/td\u003e\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN rail\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConcurrent Neutral Switching\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-circuit Tripping Threshold\u003c\/td\u003e\u003ctd\u003e400-560 A (D curve 10-14 In)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSKU\/Reference\u003c\/td\u003e\u003ctd\u003e408151\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245064081511\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCarbon Footprint (Manufacturing)\u003c\/td\u003e\u003ctd\u003e3.769 kg CO2 eq.\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand DX3 MCB 4 Pole 40A Curve D Circuit Breaker | 408151 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45159435960520,"sku":"408151","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/b04ebfa1-69a7-4edc-8c91-84a85b3fa24d.webp?v=1785764915","url":"https:\/\/toolmart.me\/en\/products\/legrand-dx3-mcb-4-pole-40a-curve-d-circuit-breaker-408151","provider":"TOOLMART","version":"1.0","type":"link"}