{"product_id":"legrand-dx3-mcb-2p-05a-d-curve-6ka-circuit-breaker-408022","title":"Legrand DX3 MCB 2P 0.5A D-Curve 6kA Circuit Breaker | 408022","description":"\u003cp\u003eShop Legrand DX3 MCB 2P 0.5A D-Curve 6kA Circuit Breaker | 408022 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Thermal magnetic 2-pole circuit-breaker with 0.5A rated current, D-curve characteristic, and 6kA breaking capacity for residential and small commercial electrical installations. DIN rail mounted with IP20 protection.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand DX3 MCB 6000A is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. With a 2-pole configuration and 0.5A rated current, this device features a D-curve characteristic and 6kA breaking capacity according to IEC 60898-1 standard for household installations. The circuit-breaker also provides control and isolation functions for electrical installations and mounts securely on DIN rail. It is equipped with two DIN rail clamps positioned on the top and bottom sides, allowing independent removal when the prong busbar is still in place. The device is protected against solid bodies larger than 12.5mm (fingerproof) with IP20 protection rating according to IEC\/EN 60529 standard.\n \n This MCB can be supplied by copper cable, prong busbar (top or bottom side), fork busbar (bottom side), or Legrand HX3 plug busbar (top side). It features a label holder for clear circuit identification and ON\/OFF indication printed on the handle with red and green backgrounds for easy status identification. The device can be equipped with Legrand DX3 auxiliaries, RCD add-on modules, and various accessories for enhanced functionality. It is designed in an environmentally conscious process and complies with substance-restriction requirements including RoHS and REACH directives.\n \n With a built-in depth of 44mm and dimensions of 35.4mm width × 94.8mm height × 77.8mm depth, this 2-module device operates reliably across a frequency range of 50-60 Hz at ambient temperatures between -25°C and 70°C. The rated voltage is 400V with a rated insulation voltage of 500V and impulse withstand voltage of 4kV. The tripping threshold for short-circuits ranges between 5A and 7A (D-curve between 10In and 14In), providing optimal protection for residential and small commercial applications.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eThermal magnetic protection against overloads and short-circuits with 6kA breaking capacity\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e2-pole configuration with 0.5A rated current and D-curve characteristic tripping between 5A-7A\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDIN rail mounting with dual clamps for independent removal and easy installation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 fingerproof protection against solid bodies larger than 12.5mm\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with Legrand DX3 auxiliaries, RCD add-on modules and various accessories\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eLabel holder and ON\/OFF indication for clear circuit identification\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eOperates reliably at 50-60 Hz across ambient temperature range -25°C to 70°C\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eEnvironmentally conscious design compliant with RoHS and REACH directives\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eAccepts copper cable, prong busbar, fork busbar or HX3 plug busbar connections\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eRated voltage 400V with 500V insulation and 4kV impulse withstand voltage\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eThermal Magnetic Circuit-Breaker (MCB)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e2 poles (2P)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e0.5 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTrip Characteristic\u003c\/td\u003e\u003ctd\u003eD-curve (5A-7A short-circuit threshold, 10In-14In)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\u003ctd\u003e6 kA (Icn) at 400V according to IEC 60898-1\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400 V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\u003ctd\u003e500 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpulse Withstand Voltage\u003c\/td\u003e\u003ctd\u003e4 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency Range\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN rail\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eProtection Rating\u003c\/td\u003e\u003ctd\u003eIP20 (fingerproof)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e35.4 mm (2 modular spacings)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e94.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e77.8 mm (built-in depth 44 mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpact Strength Rating\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\u003ctd\u003e-40°C to 70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConductor Cross Section (Multi-wired)\u003c\/td\u003e\u003ctd\u003e1.5-25 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConductor Cross Section (Solid-core)\u003c\/td\u003e\u003ctd\u003e1.5-35 mm² (1.5-25 mm² for aluminium with accessory)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSupply Options\u003c\/td\u003e\u003ctd\u003eCopper cable, prong busbar, fork busbar, or HX3 plug busbar\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSupply Direction\u003c\/td\u003e\u003ctd\u003eTop or bottom\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColour\u003c\/td\u003e\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes (DX3 auxiliaries, RCD add-on modules)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eLabel Space\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNeutral Conductor Switching\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e408022\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245064080224\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCarbon Footprint (Manufacturing)\u003c\/td\u003e\u003ctd\u003e1.796 kg CO₂ eq.\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand DX3 MCB 2P 0.5A D-Curve 6kA Circuit Breaker | 408022 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45159434420424,"sku":"408022","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/23990302-7309-4b75-bb3a-071e8c00aa9b.webp?v=1785764733","url":"https:\/\/toolmart.me\/en\/products\/legrand-dx3-mcb-2p-05a-d-curve-6ka-circuit-breaker-408022","provider":"TOOLMART","version":"1.0","type":"link"}