{"product_id":"legrand-dx3-mcb-2-pole-16a-curve-d-409451","title":"Legrand DX3 MCB 2 Pole 16A Curve D Circuit Breaker | 409451","description":"\u003cp\u003eShop Legrand DX3 MCB 2 Pole 16A Curve D Circuit Breaker | 409451 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Thermal magnetic 2-pole circuit breaker with 16A rating and D-curve tripping for overload and short-circuit protection in residential and commercial installations. Features 16kA breaking capacity at 230V, DIN rail mounting, and compatibility with DX³ auxiliaries.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand DX3 MCB 2 Pole 16A Curve D is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. With a breaking capacity of 16kA at 230V and 10kA at 400V, this device features D-curve tripping characteristics suitable for circuits with high inrush currents. The MCB controls and isolates circuits while accepting DX³ auxiliaries, RCD add-on modules, and accessories for enhanced functionality.\n \n This 2-pole modular circuit breaker is engineered for residential and small commercial applications, offering reliable protection with IP20 degree of protection (fingerproof against solid bodies larger than 12.5mm). The device features DIN rail mounting with two independent clamps allowing removal without disrupting the busbar supply. With a rated voltage of 400V and impulse withstand voltage of 4kV, it operates reliably across a frequency range of 50-60Hz and ambient temperatures from -25°C to 70°C.\n \n The MCB includes convenient features such as a label holder for circuit identification and on\/off indication printed on the handle with red and green backgrounds for easy status identification. It can be supplied by copper cable, prong busbar, fork busbar, or Legrand HX3 plug busbar, and accepts connectable conductor cross-sections from 1.5-25mm² (multi-wired) or 1.5-35mm² (solid-core). The device is halogen-free, environmentally conscious, and complies with all substance-restriction requirements.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003e16kA breaking capacity at 230V with 10kA at 400V according to IEC 60898-1 standard\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eD-curve tripping characteristic with threshold between 160A and 224A (10-14 In) for high inrush current applications\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 protection rating - fingerproof against solid bodies larger than 12.5mm\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDIN rail mounting with independent top and bottom clamps for flexible installation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with DX³ auxiliaries, RCD add-on modules, and Legrand accessories\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eLabel holder and color-coded on\/off indication for easy circuit identification\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eAccepts multi-wired (1.5-25mm²) and solid-core (1.5-35mm²) conductor connections\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eHalogen-free design with environmentally conscious manufacturing process\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eOperating temperature range -25°C to 70°C with storage range -40°C to 70°C\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCan be supplied by copper cable, prong busbar, fork busbar, or HX3 plug busbar\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eThermal Magnetic Circuit Breaker (MCB)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e2 poles (2P)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e16 Amperes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelease Characteristic\u003c\/td\u003e\u003ctd\u003eD-curve (10-14 In)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\u003ctd\u003e500V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\u003ctd\u003e4kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity at 230V (Icn)\u003c\/td\u003e\u003ctd\u003e16kA according to EN 60898\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity at 400V (Icn)\u003c\/td\u003e\u003ctd\u003e10kA according to EN 60898\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eUltimate Breaking Capacity at 230V (Icu)\u003c\/td\u003e\u003ctd\u003e32kA according to IEC 60947-2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eUltimate Breaking Capacity at 400V (Icu)\u003c\/td\u003e\u003ctd\u003e16kA according to IEC 60947-2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency Range\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection (IP)\u003c\/td\u003e\u003ctd\u003eIP20\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Impact Strength (IK)\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAmbient Operating Temperature\u003c\/td\u003e\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMulti-wired Conductor Cross Section\u003c\/td\u003e\u003ctd\u003e1.5-25 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSolid-core Conductor Cross Section\u003c\/td\u003e\u003ctd\u003e1.5-35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModular Width\u003c\/td\u003e\u003ctd\u003e2 spaces (35.4mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOverall Height\u003c\/td\u003e\u003ctd\u003e94.8mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOverall Depth\u003c\/td\u003e\u003ctd\u003e77.8mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBuilt-in Depth\u003c\/td\u003e\u003ctd\u003e44mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColour\u003c\/td\u003e\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConcurrently Switching Neutral\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes (DX³ auxiliaries, RCD modules)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eExplosion-proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e409451\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3414970434210\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCarbon Footprint (Manufacturing)\u003c\/td\u003e\u003ctd\u003e1.722 kg CO₂ eq.\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSupply Options\u003c\/td\u003e\u003ctd\u003eCopper cable, prong busbar, fork busbar, or HX3 plug busbar\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand DX3 MCB 2 Pole 16A Curve D Circuit Breaker | 409451 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45172741406920,"sku":"409451","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/9e4d91be-5cfc-4630-8b05-d0c8aeae92b9.webp?v=1786554478","url":"https:\/\/toolmart.me\/en\/products\/legrand-dx3-mcb-2-pole-16a-curve-d-409451","provider":"TOOLMART","version":"1.0","type":"link"}