{"product_id":"legrand-dx3-mcb-10000a-4-pole-16a-b-curve-409065","title":"Legrand DX3 MCB 4 Pole 16A B-Curve Circuit Breaker | 409065","description":"\u003cp\u003eShop Legrand DX3 MCB 4 Pole 16A B-Curve Circuit Breaker | 409065 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Thermal magnetic 4-pole circuit-breaker with 16A B-curve, 10kA breaking capacity at 400V, IP20 protection, and DIN rail mounting for reliable residential and commercial electrical protection.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand DX3 MCB 10000A is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. With a 16A B-curve rating and 10kA breaking capacity at 400V, this four-pole breaker provides reliable protection and control for residential and small commercial applications. The device features IP20 protection, making it suitable for standard indoor installations, and can be equipped with various Legrand DX3 auxiliaries and RCD add-on modules for enhanced functionality.\n \n This circuit-breaker is engineered with advanced current-limiting technology (Class 3) to minimize let-through energy during fault conditions. The B-curve characteristic ensures rapid tripping between 3 and 5 times the rated current, providing optimal protection for typical residential circuits. The breaker features DIN rail mounting with dual clamps for independent removal, even when the prong busbar is energized, ensuring safe maintenance and installation flexibility.\n \n The MCB DX3 is constructed with halogen-free materials and complies with substance-restriction requirements, demonstrating Legrand's commitment to environmental sustainability. It features a convenient label holder for circuit identification and clear ON\/OFF indication on the handle with red and green backgrounds for easy status recognition. Compatible with copper cables, prong busbars, fork busbars, and Legrand HX3 plug busbars, this versatile breaker is suitable for diverse installation configurations.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eBreaking capacity of 10,000A according to IEC 60898-1 standard for household installations\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eB-curve characteristic with tripping threshold between 48A and 80A (3-5 times rated current)\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 protection against solid bodies larger than 12.5mm for fingerproof safety\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCurrent limiting Class 3 for maximum energy limitation during short-circuit conditions\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eDIN rail mounting with dual clamps allowing independent removal during operation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with copper cables, prong busbars, fork busbars, and Legrand HX3 plug busbars\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eHalogen-free construction with environmentally conscious design\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIntegrated label holder for clear circuit identification\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eON\/OFF indication with red and green backgrounds for easy status recognition\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCan be equipped with Legrand DX3 auxiliaries and RCD add-on modules\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eThermal Magnetic Circuit-Breaker (MCB)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e4 poles (total and protected)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e16 Amperes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelease Characteristic\u003c\/td\u003e\u003ctd\u003eB-curve (3-5 times rated current)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity at 400V\u003c\/td\u003e\u003ctd\u003e10,000A (Icn according to EN 60898)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity at 230V\u003c\/td\u003e\u003ctd\u003e16,000A (Icn according to EN 60898)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eUltimate Breaking Capacity at 400V\u003c\/td\u003e\u003ctd\u003e16,000A (Icu according to IEC 60947-2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e400V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\u003ctd\u003e500V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\u003ctd\u003e4,000V (4 kV)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eVoltage Type\u003c\/td\u003e\u003ctd\u003eAC (Alternating Current)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency Range\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCurrent Limiting Class\u003c\/td\u003e\u003ctd\u003eClass 3 (maximum energy limitation)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP20 (fingerproof against solid bodies \u003e 12.5mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Impact Strength\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting Method\u003c\/td\u003e\u003ctd\u003eDIN rail (35mm standard rail)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth in Modular Spacings\u003c\/td\u003e\u003ctd\u003e4 modules (70.8 mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e94.8 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e77.8 mm (built-in depth 44 mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnection Type\u003c\/td\u003e\u003ctd\u003eScrewed terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section (Solid)\u003c\/td\u003e\u003ctd\u003e1.5-35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section (Multi-wired)\u003c\/td\u003e\u003ctd\u003e1.5-25 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eElectric Supplying Direction\u003c\/td\u003e\u003ctd\u003eBy the top or bottom\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConcurrently Switching Neutral Conductor\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes (Legrand DX3 auxiliaries and RCD modules)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eColour\u003c\/td\u003e\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHalogen Free\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eExplosion-proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCarbon Footprint (Manufacturing)\u003c\/td\u003e\u003ctd\u003e3.671 kg CO₂ eq.\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e409065\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245064090650\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand DX3 MCB 4 Pole 16A B-Curve Circuit Breaker | 409065 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45159438024904,"sku":"409065","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/ae1af90b-1893-4ed3-95fd-9da4c03cc287.webp?v=1785765198","url":"https:\/\/toolmart.me\/en\/products\/legrand-dx3-mcb-10000a-4-pole-16a-b-curve-409065","provider":"TOOLMART","version":"1.0","type":"link"}