{"product_id":"legrand-dx3-mcb-1-pole-125a-curve-d-circuit-breaker-409816","title":"Legrand DX3 MCB 1 Pole 125A D-Curve Circuit Breaker | 409816","description":"\u003cp\u003eShop Legrand DX3 MCB 1 Pole 125A D-Curve Circuit Breaker | 409816 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Single-pole 125A D-curve thermal magnetic circuit breaker with 25kA breaking capacity, designed for reliable overload and short-circuit protection in residential and commercial electrical installations.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Legrand DX3 MCB (Miniature Circuit Breaker) is a thermal magnetic circuit-breaker designed to protect wiring installations against overloads and short-circuits. With a rated current of 125A and D-curve characteristic, this single-pole breaker provides reliable protection with a breaking capacity of 25kA at 230V AC. The device features a red\/green mechanical indicator displaying the open or closed status of contacts, along with a label holder for clear circuit identification. It is suitable for flush-mounted installation and complies with IEC 60947-2 standards for electrical safety.\n \n This circuit breaker is engineered with advanced thermal-magnetic technology that ensures precise tripping at short-circuit currents between 1250A and 1750A (D-curve between 10 In and 14 In). The DX3 can be equipped with Legrand auxiliaries, RCD add-on modules, and various accessories to enhance functionality. It offers IP20 protection rating against solid bodies larger than 12.5mm and operates reliably in ambient temperatures ranging from -25°C to 70°C. The device is designed for use with copper cables (top or bottom side connection) and can accommodate multi-wired conductors from 6-50mm² or solid-core conductors from 6-70mm².\n \n The product incorporates environmentally conscious design principles and complies with substance-restriction requirements. Installation should be performed by qualified electricians in accordance with local electrical codes and regulations. The DX3 provides both control and isolation functions for the installation, making it an essential component in modern electrical distribution systems.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eThermal magnetic protection with 25kA breaking capacity at 230V AC\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eD-curve characteristic with tripping threshold between 1250A-1750A for short-circuit protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSingle-pole design rated at 125A for residential and small commercial applications\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eRed\/green mechanical indicator displaying open\/closed contact status with label holder\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 protection rating against solid bodies larger than 12.5mm and fingerproof design\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with Legrand DX3 auxiliaries, RCD add-on modules and accessories\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eFlexible conductor connection supporting 6-50mm² multi-wired or 6-70mm² solid-core cables\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eEnvironmentally conscious design complying with substance-restriction requirements\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eReliable operation in ambient temperatures from -25°C to 70°C\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompliant with IEC 60947-2 international electrical safety standards\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eMiniature Circuit Breaker (MCB) - Thermal Magnetic\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of Poles\u003c\/td\u003e\u003ctd\u003e1 pole (single-pole)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Current\u003c\/td\u003e\u003ctd\u003e125A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Voltage\u003c\/td\u003e\u003ctd\u003e230V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\u003ctd\u003e500V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\u003ctd\u003e6 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking Capacity\u003c\/td\u003e\u003ctd\u003e25 kA at 230V (Icu according to IEC 60947-2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTrip Characteristic\u003c\/td\u003e\u003ctd\u003eD-curve (1250A-1750A short-circuit tripping between 10In-14In)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFrequency\u003c\/td\u003e\u003ctd\u003e50-60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBuilt-in Depth\u003c\/td\u003e\u003ctd\u003e47 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e26.7 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e127.5 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTotal Depth\u003c\/td\u003e\u003ctd\u003e79.2 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth in Modular Spacings\u003c\/td\u003e\u003ctd\u003e1.5\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection (IP Rating)\u003c\/td\u003e\u003ctd\u003eIP20 (fingerproof against solid bodies \u003e12.5mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eImpact Strength Degree (IK Rating)\u003c\/td\u003e\u003ctd\u003eIK02\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section - Multi-wired\u003c\/td\u003e\u003ctd\u003e6-50 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable Conductor Cross Section - Solid-core\u003c\/td\u003e\u003ctd\u003e6-70 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\u003ctd\u003e-25°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNominal Voltage Range\u003c\/td\u003e\u003ctd\u003e210-250V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution Degree\u003c\/td\u003e\u003ctd\u003e3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounted Installation\u003c\/td\u003e\u003ctd\u003eYes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConcurrently Switching Neutral\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eAdditional Equipment Possible\u003c\/td\u003e\u003ctd\u003eYes (Legrand DX3 auxiliaries, RCD modules, accessories)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eExplosion-proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e409816\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3245064098168\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCompliance Standards\u003c\/td\u003e\u003ctd\u003eIEC 60947-2, IEC\/EN 60529\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCarbon Footprint (Manufacturing)\u003c\/td\u003e\u003ctd\u003e1.498 kg CO₂ eq.\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand DX3 MCB 1 Pole 125A D-Curve Circuit Breaker | 409816 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45172746387656,"sku":"409816","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/a3583231-0466-4550-9fdd-f7de4a0428af.webp?v=1786554986","url":"https:\/\/toolmart.me\/en\/products\/legrand-dx3-mcb-1-pole-125a-curve-d-circuit-breaker-409816","provider":"TOOLMART","version":"1.0","type":"link"}